Filter Results By:
Products
Applications
Manufacturers
- InterWorking Labs, Inc.
product
Network Emulation System
Mini Maxwell
Mini Maxwell -- Easy to use, portable, network emulator. Mini Maxwell''''s low cost of $1995 can fit into any testing budget. The Mini Maxwell is great if you have low power requirements, or need ultra quiet operation. Mini Maxwell supports packet drop/loss, duplication, delay (latency)/jitter, reorder, and burst. Includes: processor, memory, and three Ethernet interfaces in one enclosure with separate power supply, Linux OS, Mini Maxwell network emulator engine, graphical user interface, and 90 Day Warranty.
-
product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (f)
CK058F
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
LV Iron Core Harmonic Filters
Nonlinear loads such as power electronics based equipment and electric furnaces are sources of harmonic currents leading to harmonic distortion, which is one of the most important parameters for defining the power quality. Most of the commercial loads such as personal computers, photocopy machines, power supplies, and compact fluorescent lamps; and industrial loads such as AC and DC motor drives inject harmonic currents into the network that they are connected to.
-
product
Bench-Top & Shop Loader Solutions
Avionics Interface Technologies
To satisfy ARINC 615/615A data loader requirements in system engineering labs, avionics system manufacturing, and maintenance depot applications, AIT provides data loader software that can be used together with AIT’s full line of ARINC 429, ARINC 664, and Ethernet interface modules and integrated into a variety of host desktop PC systems and ATE environments. The F-SIM-LDR-615 software provides ARINC 615-3/4 data loader support and is compatible with all of AIT’s ARINC 429 interface modules. The F-SIM-LDR-615A software application provides ARINC 615A-1 /2/3 data loader support over Ethernet and ARINC 664 networks and is compatible with all of AIT’s ARINC 664/Ethernet interfaces modules. The F-SIM-LDR-615 and F-SIM-LDR-615A software products include both graphical user interface (GUI ) data loader applications and command line data loaders which are scriptable and can be called from shell scripts, batch files, and python for support of automated load operations.
-
product
4-in-1 OSLT Calibration Kit, DC to 50 GHz, 2.4 mm (m)
CK564A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
2-Port 20 GHz Analyzer, Direct Receiver Access
C2220
C2220 Vector Network Analyzer delivers industry-leading dynamic range and sweep speed, with all the features engineers have come to expect included standard in our software. The C2220 network analyzer has direct receiver access for special applications involving external directional coupling, including Load Pull and high power measurements.
-
product
4-in-1 OSLT Calibration Kit, DC to 40 GHz, 2.92 mm (m)
CK562A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
T3SP Time Domain Reflectometers
T3SP Series
Teledyne Test Tools T3SP15D stimulates the DUT with true differential signals. The T3SP15D offers fast rise times of 35 ps for spatial impedance resolution (in FR4) of 3 mm, at DUT lengths up to 40 meters and TDR repetition rates up to 10 MHz and uses the same open short load thru (OSLT) calibration standards as vector network analyzers. With their small form factors, light weight, and optional internal batteries, the instruments go anywhere in test labs or in the field at an affordable price.
-
product
Automatic Capacitor Batteries
Lifasa - International Capacitors, SA
The batteries of capacitors for automatic AT are designed for those applications in which the power levels in the AT network are variable. This type of equipment, with a number of steps normally between 2 and 4 to avoid phenomena in the installation resulting from the connection and disconnection of the capacitors in the electrical network, is controlled by a type MCX regulator, which tunes and regulates the input of the steps according to load levels, taking into account the expected waiting times of AT that between consecutive connections is 600 s., this time we can reduce it to less than 10 s. if we install TP for fast download.
-
product
40 Gigabit Ethernet AdvancedTCA® Fabric Interface Switch Blade
aTCA-3710
The aTCA-3710 is a high performance, high bandwidth, 40G Fabric switch blade for AdvancedTCA® platforms. This product is ideal for bandwidth intensive telecom applications such as wireless access controller, DPI/security network, IPTV, IP multimedia subsystem, RNC/BSC, broadband access/bearer network, data center, and LTE/4G network applications. The aTCA-3710 provides 40GbE hub-to-node connectivity and integrated switch silicon that supports load balancing, priority queues, packet classification, and flow control to enable strict bandwidth management for implemented applications.
-
product
Software
SSI-TRES
Was developed to read and edit Plug and Play Smart Sensors that are compliant to the IEEE 1451.4 Standard. TEDS, or transducer Electronic Data Sheet, is a set of electronic data in a standardized format defined within the IEEE 1451.4 standard. This data specifies what type of sensor is present, describes its interface, and gives technical information such as sensitivity, bridge type , excitation, etc. This information is stored in an EEPROM chip attached to the sensor. By having this chip, the sensor can identify and describe itself to the network and or Smart Load Cell Meter (DPM-3), thereby easing automatic system configuration.
-
product
Dual-channel AMR Modem
Signals & Systems India Private Limited
DUAL-CHANNEL AMR is a combined Modem for remote reading & local reading via Bluetooth through the mobile app without opening the enclosure/seals. Dual Channel AMR Modem is an innovative device that can be connected to any make of electronic energy meter by means of optical/ RS232 port, which is compliant to DLMS – IEC 62056-21 standard. AMR system is compatible with 4G network to push the power consumption-billing data, load survey data, and event data to a cloud-based server, with fallback to 3G & 2G. The modem can be programmed to send any abnormal events to any number instantly. The modems have a ‘store and forward’ facility.
-
product
Versatile RF Network Analyzers for LF and MF
TE3000-series
The TE3000-series of RF vector network analyzers have full vector measurement capability, and accurately resolves the resistive, capacitive and inductive components of a load. The user can display the vector impedance plus a range of related parameters including SWR, reflection coefficient, return loss and R-L-C equivalent circuit.
-
product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (m)
CK058M
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Air Core Harmonic Filter Reactors
Use of nonlinear loads such as power electronics based equipment and electric furnaces have been on the rise for the last decades. Such loads decrease the power quality of the network that they are connected to. One of the most important parameters for defining the power quality is harmonic distortion.
-
product
Test Engines
Verified Systems International GMBH
The test system cluster architecture is based on dual CPU or 4-CPU PCs acting as cluster nodes. The nodes communicate and synchronise over a high-speed network (Myrinet or InfiniBand). A modification of the Linux operating system allows to run the test execution and evaluation algorithms in hard real-time on reserved CPUs, where scheduling is non-preemptive and controlled by the test system itself. The interrupts caused by interfaces to the system under test may be relayed to CPUs designated explicitly for their handling. This approach offers the opportunity to utilise high-performance standard hardware and the services provided by the widely accepted Linux operating system in combination with all mechanisms required for hard real-time computing. The cluster architecture presents an opportunity to distribute interfaces with high data throughput on different nodes, so that PCI bus overload can be avoided. In addition, the CPU load can be balanced by allocating test data generators, environment simulations and checkers for the behaviour of the system under test ("test oracles") on dedicated CPUs.
-
product
Cable & Antenna Analyzer
CAA-100
ShinewayTech® CAA-100 cable & antenna analyzer can test Return Loss and VSWR of load’ frequency. Also can get Return Loss, VSWR of DTF (distance-to-fault) and Cable Loss. Users can be easy to know the connection of cable & antenna system is reliable whether or not. CAA-100 series with frequency range 25MHz-4GHz and 60dB dynamic range can suitable for 2G/3G/4G/WiMAX system etc. CAA-100 series is the necessary measuring instrument for the new generation of wireless network development, upgrade and maintenance.
-
product
±6 kV ANSI/ESDA/JEDEC HBM Test System
HBM-TS10-A
High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C
-
product
Automatic Calibration Module
ACM2520
ACM2520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full 2-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
product
±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester
HBM-S1-B
High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm
-
product
Load Testing for Evolved Packet Core (ePC/VePC)
Flare
Linkbit Flare is designed for load testing of Evolved Packet Core (ePC) networks, and the upcoming VePC deployments. It is based on the technology initially develped for Linkbit functional testers, and as a result is extremely flexible.
-
product
Coaxial Calibration Kits
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Rosenberger offers the following types of calibration kits with a range of coaxial connector series for vector network analyzers (VNAs). All Rosenberger calibration kits can be used from DC to their maximum frequency. Full version with adaptors and sliding loads for variable measurements Industrial version for standard measurements LRL and TRL version
-
product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
product
DDoS Scrubbing Centre Diversion Automation
Using a scrubbing centre as a network traffic diversion strategy during a DDoS attack is one of the most effective ways to mitigate an attack’s effects on your network. Malicious traffic is rerouted from your network to a scrubbing centre, giving you the opportunities to filter traffic while reducing your network load.
-
product
Automatic Calibration Module
ACM4509
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
product
Outdoor Exposure Tester
OET
A comprehensive analysis of PV modules includes many different parameters. Determining the normal module operating temperature (NMOT), incidence angle effects and comparing soiling effects on different modules up to the initial degradation of PV modules are all parameters that can be analyzed with our outdoor exposure tester. The tester comes with up to twelve electronic loads installed in a 19" rack. The loads have two main functions: maximum power point tracking (MPPT) and IV curve tracing. For the advanced analysis, it is possible to change between these two modes within one test. In the normal operation mode, the electronic load keeps the module under MPP and each predefined interval an IV curve is traced. The entire tester comes with all necessary sensors such as temperature sensor, which can be attached to the module to determine the NMOT temperature like defined in IEC 61215 (MQT 05) and IEC 61853-2. The irradiation sensor is also included. In combination with our tracking system P2, it is also possible to determine incident angle effects of the PV module. It is also possible to connect other irradiation sensors for diffuse and direct irradiation, which helps to understand the behavior of the module in different irradiation conditions. An optional albedo meter is a powerful tool for the analysis of bifacial modules. The entire graphical user interface is web based and offers the possibility to access the system from the all computers in the network.
-
product
VoIP Monitoring and Testing Tool
SIP Tester™
StarTrinity SIP tester™ is a VoIP load testing tool which enables you to test and monitor VoIP network, SIP software or hardware. It is able to simulate and passively monitor thousands of simultaneous incoming and outgoing SIP calls with RTP media, analyze call quality and build real time reports.
-
product
Enterprise-Scale Application and Security Testing
PerfectStorm ONE 1GE/10GE Appliance
Keysight Network Applications and Security
PerfectStorm ONE facilitates network and security proof-of-concepts (POCs) and assessments, all in a compact device. This POC-in-a-box enables enterprises and service providers to select optimal devices and right-size data centers, as well as providing device vendors with a platform to fully showcase their product’s performance, resiliency, and throughput under realworld traffic loads.
-
product
Distribution Transformer Tester
NDB-DOC-3™
The NDB-DOC-3™ is a test instrument designed for distribution networks transformers from 5kVA to 3MVA. It can determine the presence of short circuits or open circuits in the distribution transformer primary winding & also short circuits on the secondary winding.The NDB-DOC-3™ is designed to be operated without disconnecting the transformer’s secondary windings from their loads.
-
product
Telemetry Handheld Display
TW-3.0-T
The TW-3.0-T Telemetry Handheld Display is a modern, slimline, multifunctional load monitoring device which is unique to DLM.This innovative design is built with the user in mind. It has a large, high quality LCD screen which is optically bonded removing the need for a back light and improving clarity in bright sunlight. There are 12 devices on the network which can each be given a customisable friendly name made visible on the screen to make instant identification possible.
-
product
Mid Energy Counters
UEM1P5-4D R for RS485 Modbus RTU/ASCII communicationUEM1P5-D M for M-Bus communicationUEM1P5-4D E for Ethernet (Modbus TCP) communicationFor 1 or 5A CTProgrammable CT ratioFully bi-directional four quadrants measurements for all energies and powersFor 3 / 4 wire networks with balanced or unbalanced load (UEM1P5-4D R and UEM1P5-4D E only for 4 wire networks)Class B according to EN 50470-3S0 output for energy pulse emissionAvailable with MID certification