PXI 16 to 1 Mux 1GHz 50Ohm SMB
40-747-511
The 40-747 is a single 16 to 1 RF MUX available in 50 Ohmhm or 75 Ohmhm versions occupying a single PXI slot. The module is available with SMB or SMA connectors for 50 Ohmhm versions or, 1.0/2.3 or Mini SMB connectors for 75 Ohm versions. Applications for the 40-747 include routing high frequency signals to and from oscilloscopes, analyzers, signal generators and synthesizers, telecoms tributary switching, video/audio switching and switching high frequency logic signals
-
product
PXI 2A Multiplexer, 16-Bank, 4-Channel 2-Pole
40-614A-002
This 16-bank, 4-channel, 2 pole version is part of the 40-614A High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.These 2A multiplexer modules are designed for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
PXI Dual SP6T Multiplexer 18GHz 50, SMA, Terminated
40-785B-522-T
The 40-785B-522-T is a dual 6-channel 18GHz terminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI Very High Density MUX 10 Chan 16 Pole
40-675-002-10/16
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
product
PXI 2A Multiplexer, 2-Bank, 32-Channel, 2-Pole
40-614B-011
This 2-bank, 32-channel, 2-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
LXI High Voltage Switching - 4-Bank, 1-Pole, 4:1 Multiplexer Plugin Module
65-231-913
The 65-231-913 plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 3-Channel, 4-Pole
40-514-101
The 40-514-101 (PXI) and 42-514-101 (PXIe) are low density multiplexers in dual 3-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
PXI/PXIe MIL-STD-1553 Multiplexer, Dual 4-Channel, 2-Pole
42-739-006
The 40-739-006 (PXI) and 42-739-006 (PXIe) are dual 4-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
product
PCI High Density Screened MUX 99 Ch 1 Pole
50-670-021-S-99/1
The 50-670 series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
product
PXI/PXIe MEMS Optical Switch, Quad Insert/Bypass, Single-Mode
40-860A-432-HI
The 40/42-860A-432-HI is a PXI/PXIe quad insert/bypass switch with MU connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 40GHz, 50Ω, SMA-2.9, Remote Mount
40-784B-042-E
The 40-784B-042-E (PXI) and 42-784B-042-E (PXIe) are dual SP6T 40GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
PXIe-2527, 32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module
780587-27
32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module—The PXIe‑2527 is a high‐voltage PXI multiplexer switch module that is ideal for medium‑ to high‑density automated test applications. Featuring high-power electromechanical relays, the PXIe‑2527 is the perfect front end for the PXI DMM modules, offering simple channel expansion for a variety of measurements. The PXIe‑2527 supports multiple channel configurations including 64x1 1‑wire, 32x1 2‑wire, and 16x1 4‑wire. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
product
PXI 3A Power MUX BRIC, 9-Channel, 16-Pole
40-571-203
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Failsafe
42-785C-573-E
The 40-785C-573-E (PXI) and 42-785C-573-E (PXIe) are triple failsafe SP6T 67 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI 3A Power MUX BRIC, 16-Channel, 12-Pole
40-571-304
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
product
PXI High Voltage Power Multiplexer, Dual 12:1
40-331A-002
The 40-331A-002 dual 12:1 MUX is part of our range of 40-331A/332 High Voltage Power Multiplexer and Matrix Modules and is suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching.
-
product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 6GHz, 50Ω, SMA, Remote Mount
40-784B-103-E
The 40-784B-103-E (PXI) and 42-784B-103-E (PXIe) are triple SP4T 6GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
LXI Microwave Multiplexer, 50Ω 6-Channel 4-Bank 40GHz SMA-2.9
60-801-404
The 60-801-404 is a 6-channel, 4-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
LXI Microwave Multiplexer, SP4T, 10-Bank, 18GHz, 50Ω, SMA
60-803-110
Our 60-803-110 is a 10 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXI Versatile Multiplexer, Solid State, 350mA, 60V
40-681A-001
The 40-681A-001 is a very high-density versatile PXI Multiplexer module featuring a wide range of selectable switching configurations with 350mA current and 60V voltage handling. The 40-681A is especially useful where a high-density MUX array is required that can adapt to different test configurations for different test targets, or where a test system may have to be reconfigured in the future.
-
product
PXIe Microwave Multiplexer, Dual SP4T, 26.5 GHz, 50 Ω, SMA, Failsafe
42-785C-432
The 40-785C-432 (PXI) and 42-785C-432 (PXIe) are dual failsafe SP4T 26.5 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP10T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-122-TE
The 40-788-122-TE (PXI) and 42-788-122-TE (PXIe) are dual failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
product
PXI 3A Power MUX BRIC, 24-Channel, 12-Pole
40-571-306
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber
40-852A-318-M50
The 40/42-852A-318-M50 is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 32-Channel, 2-Pole
42-614D-011
The 40-614D-011 (PXI) and 42-614D-011 (PXIe) 2-bank, 32-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PCI 2 Amp Multiplexer, Single 4-Channel, 8-Pole
50-635A-104
The 50-635A-104 is a single 4-channel, 8-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI Dual SP4T Multiplexer 26.5GHz 50 SMA
40-784A-132
Pickering Interfaces’ range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50Ω and are capable of switching signals up to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors
-
product
2x (1 to 8) 50 Ohm 2.5GHz Mux with Self Test Relays
YAVAM308
5x (1×4) Mux + 2x Pass trough30Vac/dc, 10W MaxSelftest functionMax current 500mACAN Control (or Ethernet with Ethernet to CAN Gateway)Reflexive
-
product
PXI Microwave Multiplexer, Single SP6T, 26.5GHz, 50Ω, SMA, Terminated
40-785C-531-T
The 40-785C-531-T (PXI) and 42-785C-531-T (PXIe) are single SP6T 26.5GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
LXI Microwave Multiplexer, SP6T, 8-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-508
Our 60-800-508 is a 8 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.