Current Loggers
See Also: Loggers, Pressure Loggers, Dataloggers, Humidity Loggers, Temperature Humidity Loggers, Temperature Loggers, Voltage Loggers, Wireless Data Loggers, Wireless Loggers, Data Loggers
-
Product
Programmable DC Current Source
Model 121
-
The Model 121 programmable DC current source is a precision instrument suitable for bench-top use or panel-mounted operation in labs, test facilities, and manufacturing environments. It provides a low-noise, highly stable source of current up to 100 mA, with convenient manual selection through 13 pre-set output levels, each representing a ten-fold change in power when attached to a resistive load. A “user” setting allows the current output to be defined anywhere within the operating range of the unit, from 100 nA to 100 mA.
-
Product
Eddy Current Test System
CIRCOGRAPH® Product Family
-
Foerster Instruments, Incorporated
The CIRCOGRAPH eddy current test system with rotating probes guarantees maximum detection sensitivity for exposed longitudinal surface defects on bright material. The test system is primarily used for wire drawing machines, Cu tube rewinders, and finishing sections in the bright steel sector. The individually tailored test systems by FOERSTER can be fitted with rotating sensors or CIRCOSCAN rotating discs. They scan flat and profiled material, e.g. when testing rails and billets.
-
Product
Current Probes
-
Any one of several techniques used to measure electric current. The measurement of current ranges from picoamps to tens of thousands of amperes.
-
Product
Current Probe
PA-699
-
*High sensitivity: 1mA, High frequency: 1.5MHz. They are all 10 multiple calculation. Calculation is not making mistakes.*Max measuring current: +/- 40A DC / 80 Ap-p*Max sensitivity: ≧1mA*Bandwidth: DC ~ 1.5 MHz*Rising Time: 0.23 uS*Overload indicator*1V/A, 0.1V/A 2 ranges selectors*Input power switching (priority circuit) and battery available*Dispatching design, high durability
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-80
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Big CT window*AC 1A~1800A*Current measurements of main cable
-
Product
Temperature Logger
TRIL-8
-
The LogTag® Dry Ice “Probe-less” Temperature Logger operates, measures and stores up to 8000 temperature readings in temperature environments ranging from -80°C to +40°C (-112°F to +104°F).
-
Product
Constant Current System
CCS-BTA
-
Vernier Software & Technology, LLC
The Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments.
-
Product
Extra-Ground Current Impuision Equipment
JYQ
-
Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.
-
Product
Current Sensors
-
Our current sensors were designed for a simple, customer-specific construction of niobium wire wound magnetometers, gradiometers or preamplifiers for small current or voltage signals.
-
Product
10 Channel Data Logger
-
Unitech Scales And Measurements Pvt. Ltd
10 Channel - CH-1 : Fuel flow - CH-2 : Air flow - CH-3 : Water flow - CH-4 : Voltage - CH-5 : Current - CH-6 : Inlet water Temperature - CH-7 : Outlet water Temperature - CH-8 : Room Temperature - CH-9 : Exhaust Temperature - CH-10 : Speed
-
Product
Primary Current Injection Kits
-
During installation,testing,especially if the protective gear is connected to the power line via a current transformer it is advisable to use our Primary Injection Test Set. Keeping this in mind a wide range of Primary Current Injection Test Sets are being manufactured by "NMC”.
-
Product
Current sensors
-
Assistance systems support the driver and assure safety in the latest generation of automobiles. Infotainment systems entertain passengers during car journeys and provide navigation. Seats are no longer adjusted manually, and doors are opened and closed with electric motors. The ever increasing electrification is driven by many other factors besides convenience and safety though.
-
Product
Current Shunt Module
CURS100
-
The CURS100 converts a current signal output by a sensor or output device (e.g., 4 to 20 mA) to a voltage that can be measured by a datalogger. The 100 ohm resistor used for the current shunt allows currents up to 25 mA to be read on a 2500 mV range (CR10, CR10X, CR510, CR500) and currents up to 50 mA to be read on a 5000 mV range (CR23X, 21X, CR7, CR5000, CR9000, CR9000X).
-
Product
Data Logger
ADlog
-
With ADlog, you use ADwin-Pro, ADwin-Gold and ADwin-light-16 flexibly for recording, visualizing and evaluation of large data amounts without programming effort.
-
Product
Spectroradiometer Data Logger
HD30.1
-
The HD30.1 spectroradiometer datalogger is designed for the spectral analysis of light in the visible range and ultraviolet.
-
Product
Dew Point Logger Sensor
NUL-245
-
This sensor measures temperature and humidity in a volume and gives the temperature below which the water vapor in that volume of air (at a constant barometric pressure) condenses into liquid water (the dew point).
-
Product
Logger version optical fast DO sensor
RINKO I / I D
-
Rinko I is an autonomously deployable data logger with a fast response optical DO sensor. The instrument and the software with various operating mode offer flexible observations in the field. The small-sized and the self-contained unit with batteries and a data logger can be easily integrated on platforms (e.g. CTDs). Rinko ID has a depth sensor, allowing for DO vertical distribution measurements.
-
Product
Wireless Primary Current Recorder Meter
GF2015
-
Beijing GFUVE Electronics Co.,Ltd.
GF2015 is a wireless primary current recorder equipped with a 433M for transmit the recorded data into the user''s PC by our PC-Link Software. It is a good assistant of power monitor system. The recording interval can be set from 1- 60 min. The PC-Link Software can generate reports and create graphs for profile analysis.
-
Product
Data Loggers, Data Recorders, and Measuring Transducers
-
Wuntronic Data Loggers, Data Recorders, and Measuring Transducers
-
Product
DC Bias Current Power Supply
TH1775
-
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
Product
Capacitor Leakage Current Meter
DU2316/2317
-
Delta United Instrument Co., Ltd.
Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed
-
Product
Thermometer Hygrometer Data Logger
S3120
-
Data logger is designed for record of temperature and humidity. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter.
-
Product
Current Logger0 to 25mA DC
TV-4804
-
The TV-4804 measures current from 0 to 25mA DC and can be connected to a variety of industry standard sensors enabling the logging of a wide range of process parameters.
-
Product
Current Tester
MIG0624
-
The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.
-
Product
Sensors - Stand-Alone Loggers
-
Makes it possible to measure and record the transport conditions of goods and to trace shocks as well as temperature variations.
-
Product
Dual Voltage Buffer with Current Drive
BUF-01
-
The BUF-01 Voltage Buffer is a dual channel buffer capable of driving up to 50 mA of current on each channel at up to ±10 V output. The buffer has a 2nd order low pass filter with 3 dB point of 119 kHz to remove high frequency noise. The unit’s differential inputs are built to withstand high DC over-voltages up to ±50 VDC and greater than ±100 V transients. Gain of the unit is 1 allowing for minimal insertion issues.
-
Product
Current Probe
PA-629
-
*Maximum Current Value: +/- 200ADC, 140A RMS*1mA = 10mA, 100mA (switchable)*Rising Time: 1.2uS*Bandwidth: DC ~ 300kHz*Over Range Indicator*Battery, AC Power Supply Adaptor (free), dual usages
-
Product
USB-COM Data Logger
-
The USB-COM Utility is a free data logging andconfiguration program for use with the Validyneseries of USB or Serial pressure transducers.USB-COM Utility also comes in a premiumversion that allows up to eight signals to begraphed simultaneously while being recorded toa .csv file. The graph X and Y axis may bescaled to any values set by the user. A separatehistorical graph provides a complete visualrecord of the signals from the start of logging.
-
Product
Voltage Data Logger Two Channels with USB
VA602-V1-V1
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Two tunnel data logger with voltage current temperature (thermocouple) K.J.PT type, with USB, up to 16000 data record point.





























