Fault Location
Determine the location of faults.
-
product
Cable and Pipe Locator
PT-14
The locator PT-14 is used as an induction signal receiver in a cable tracing and fault location set for the following applications:• tracing – finding the route and determining the burial depth of underground cables and other hidden utilities;• fault location – pinpointing interphase and phase-to-sheath short circuits faults;• cable identification – identifying a correct cable from a bunch.
-
product
25-Watt Transmitter
Loc3 25W
The powerful 25-watt transmitter is the go-to transmitter for cable fault locating, finding holidays on coated pipes, problematic deep-buried lines, and long-distance pipe and cable locating. The Loc3-25Tx is also well suited for applications for cathodic protected longline pipelines and gas distribution in city areas needing a low-frequency high output transmitter.
-
product
Tool, Locator, TriPaddle, Receiver
910104127
Used with crimp tool part # 910 101 103 to crimp TriPaddle receiver contacts to 20-28 AWG wire. This locator contains an integrated wire stop for consistent contact crimping.
-
product
Visual Fault Locator VFL X5007
Metal case, Rugged and durableLow battery indication, to avoid leakage and wrong judgmentESD protection design, Protect the LD effectivelyIntegrated case, to avoid the case intermediate brokenRe-changeable ceramic tube, to avoid returning to manufacturer for this small faultLong battery life, up to 60 hours@1mW
-
product
Time Domain Reflectometer
IRG 2000
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR IRG 2000. The IRG 2000 impulse reflection measurement unit or time domain reflectometer is a handy, easy to carry device for single-phase cable fault pre-location. It is used in combination with a surge voltage generator on low-, medium- and high-voltage cables 0 - 65 km in length. It can also be used on live cables carrying voltage up to 400 V.* Easy and quick cable fault location* Light, compact and manageable* Main unit for the tried-and-tested pre-location method* Ideal for integration in measurement systems
-
product
Tool, Locator, Thermocouple, Receiver
910104134
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
product
Pen-based Fault Locator
*Find the breakpoint, bending or cracking*Find the fault of OTDR dead zone*Identification of fiber from one end to other end*Universal adaptor*Testing distance up to 8km*Lightweight, red laser output, both SM and MM available
-
product
Tool, Locator, TriPaddle, Receiver
910104146
Tool, Locator, TriPaddle, Receiver (only for contact p/n #'s 610110128 Rev C+ and 610110177)
-
product
PXI 16-Channel 4-Bus 2A Fault Insertion Switch
40-197A-002
This 16-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers.
-
product
Tool, Locator, QuadraPaddle, ITA
910104140
Used with Crimp Tool p/n # 910101103 to crimp QuadraPaddle contacts to 22-28 AWG wire.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
PXI Single Bus 64-Ch 2A Fault Insertion Switch
40-190B-101
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A, Hardware Interlock
40-191B-012-HI
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
product
Time Domain Reflectometer
ETDR 10A-1
Compact dual channel precision full function portable easy to useTDR for fault location on balanced unloaded cables.
-
product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Tool, Locator, Mini Coax, 24 AWG Wire
910104128
Used with Crimp Tool p/n# 910101118 to crimp 24-26 AWG wire to mini coax ITA contacts.
-
product
Visual Fault Locator
TM191
TM191 series visual fault locator is used for the measurement in single mode or multi-mode fibers. It features a rugged design, a universal connectorand an accurate measurement
-
product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
product
PXI Single Bus 74-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-301
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.