Filter Results By:
Products
Applications
Manufacturers
Anechoic Chambers
enclosures that dampen RF or sound reflection within and stop exterior noise.
See Also: Chambers, TEM Cells, Acoustic Chambers, Altitude Chambers, Climate Chambers, Dust Chambers, Environmental Chambers, ESS Chambers, Humidity Chambers, Refrigerated Chambers, Reverberation Chambers, RF Chambers, Salt Spray Chambers, Sound Chambers, Temperature Chambers, Temperature Humidity Chambers, Thermal Shock Chambers, Vacuum Chambers, Anechoic Rooms
- Canden Products LLC
product
Stability Testing Chamber - Single Door Model
Q40
Canden stability testing chamber is capable of maintaining stable temperature set points of 25°c , 30°c & 40°c corresponding relative humidity set points of 60%RH(@25°c), 65%RH(@30°c) and 75% RH(@40°c) with exceptional precision. The chamber has a wide operating temperature range of 18°c t to 40°c maintaining a stable temperature across the entire range. This chamber provides outstanding stability testing performance for manufacturers of pharmaceuticals, biologics, food, and personal care products. Canden stability chambers’ performance meets ICH Q1A general case guidelines for pharmaceutical stability testing.
-
product
Anechoic Chambers
Eckel Noise Control Technologies
Anechoic Chambers are echo-free enclosures with a sound energy absorption level of 99% to 100%, or a reflected sound pressure level of 10% or less. The frequency at which the energy absorption drops below 99%, or the pressure reflection exceeds 10%, is known as the low-frequency cut-off. Sound absorption is obtained by lining the walls, ceilings, and floor with wedges or other sound absorbing elements or SuperSoft panels, depending on performance level required and cut-off desired.
-
product
Calibration
Calibrations of electronic equipment is one of the activities that Kiwa Dare offers to its clients. these calibrations are under accreditation in the field of electrical quantities. Besides calibrations in the field of DC current, DC voltage and low frequency (test and measuring) equipment, Kiwa Dare is specialized in calibrating high frequency measuring equipment and in particular EMC equipment in a frequency range of (DC) 40 GHz. New the site validation calibrations whereby Kiwa Dare can calibrate shielded rooms (Faraday room) and anechoic chambers under accreditation.
-
product
Near Field Probes
Anteral has extensive background in the design of Near Field Probes (open ended waveguides probes). Our Near Field Probes are currently being used in several laboratories around the world including the ESA's anechoic chamber. Anteral designs Near Field Probes from 10 GHz to 750 GHz covering the sectors requirements. Moreover, our Near Field Probes have a sharped design minimize reflections.
-
product
Automotive Radar Testers
Rohde & Schwarz provides automotive manufacturers, components suppliers and test houses with innovative, cutting-edge solutions which bring realistic test scenarios from the road to the lab and production line.Our range of solutions include a signal generator-based target simulator, a radome & bumper tester and an anechoic automotive radar test chamber allowing for over-the-air (OTA) testing. These solutions are at the heart of the development of advanced driver assistance systems (ADAS) with its safety-critical features such as emergency braking. Using T&M solutions by Rohde & Schwarz enables a thorough testing of chipsets, sensors and modules at each phase from development and conformance to production.
-
product
Anechoic chambers
The anechoic chambers are built up as a modular construction. Due to individual modules any size of chamber can be manufactured. Big chambers may require an outer supporting structure or alternatively the shielding material can be attached direct to the building. The absorbers are fixed to rails bars or wooden base construction which is inserted into the shielding modules.
-
product
RF Filters
Raymond RF offers a complete line of RF filters ranging from 0.4A to 600A in both stand-alone and cabinet-mounted configurations for our QuietBoxes and Anechoic Chambers. Both styles of filters can be supplied with NPT pipe nipples and flange nuts for mounting directly on a QuietBox or Anechoic Chamber. Alternately, both styles of filters can be remotely mounted with shielded conduit running between the clean end of the filter and the QuietBox or Anechoic Chamber.
-
product
Chambers
Our EMC anechoic chamber solutions paired with the Frankosorb® unique non-combustible absorber technology, we are the first choice when it comes to reliable and state-of-the-art test facilities. Our solutions are adapted to every kind of vehicle and its different power train units, incl. hydrogen, gasoline, petrol, from small-sized passenger cars up to large and heavy-weight transport vehicles.
-
product
Three Meter Fully Compliant Chambers
3 Meter Fully Compliant semi-anechoic chambers offer semi-anechoic radiated emissions (RE) and fully anechoic radiated immunity (RI) compliance test capability for most international EMC compliance regulations.
-
product
Anechoic Chamber room for Automotive components
Anechoic Chamber room of most suitable Automotive devices EMI/EMS test of the method of ALSE, which meet the global standard like a 2004/104/EC, several emmission standard like a CISPR25 which automotive manufacturers in EU/USA refer to, Immunity standard like a ISO11452 and others for the Automotive devices.
-
product
Test and Measurement/ EMC
ARA offers both outdoor far field range services and indoor anechoic chambers at all of its locations. Outdoor ranges vary from 5,000 ft, 1250 ft, to 300 ft. ARA has forklifts, crane services, and man-lifts to suit your antenna size and weights. Complete RF measurement instrumentation is available for conducting all standard tests up to 40 GHz. RF testing is conducted in accordance with ANS / IEEE Std. 149-1979 "Standard Test Procedures for Antennas."
-
product
Antenna Testing Services
Our chamber measures 28' x 14' x 14' with 12" to 36" pyramidal anechoic absorbers and is fully shielded using a dual layer metal enclosure. Our test chamber is designed to for frequencies ranging from .700 to 6.00 GHz.
-
product
Automotive EMC Testing
Having been assessed by Ford Detroit’s EMC expert, we are Australia’s only Ford (and NATA) accredited automotive EMC test laboratory. Others have tried, but none have succeeded. Ford does not accept reports from EMC labs that are not on the Ford list of accredited labs. The scope ranges from component to complete vehicle level EMC testing for Australian and overseas manufacturers. We also have a fully dedicated CISPR 25 Electronic Sub Assembly (ESA) chamber, another large CISPR 25 anechoic chamber for vehicle testing or susceptibility levels in excess of 500V/m. We possess a vast array of specific automotive EMC test equipment such as BCI’s, tri-plate’s, and striplines for susceptibility and emissions testing to meet the most stringent automotive EMC requirements. Our Australian and overseas customers use our labs because they know that our reports will be accepted and will not be questioned.
-
product
Hand-In Type Electromagnetic Anechoic Box (Shield Box)
MY3720
Suitable for weak electric field resistance test, out-of-service test or digital forensics for smart phone, tablet terminal or mobile PC ! !DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.
-
product
Dynamometer
Innco Systems EMC Chassis Dynamometer Systems (sometimes referred to as a ‘’rolling road’’), used in the development and homologation for Automotive Industry, are specifically designed to be used in Anechoic Chambers.
-
product
Hand-In Type Electromagnetic Anechoic Box (Shield Box)
MY3710HS
Higher shielding performance than MY371080dB. Suitable for weak electric field resistance test, out-of-service test or digital forensics for mobile phone, smart phone or tablet terminal! DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.
-
product
Radiating Comb Generators
TBCG1
The TBCG1 is a radiating comb generator with an internal antenna and a base frequency of 100MHz. It radiates a comb spectrum characterized up to 6GHz. The comb generator is built and characterized to serve as a rough reference for testing radiated noise measurement set ups in anechoic chambers, TEM/GTEM cells, shielded chambers, etc.
-
product
Antenna Characterization
Radiometrics Midwest Corporation
Radiometrics Open Area Test Site and 10 Meter Anechoic chamber provide ideal test sites for antenna characterization.
-
product
Loudspeaker Testing
TTC
The weakest link in your measurement chain is your chamber, the new TTC chambers solve these problems...*Anechoic chambers have massive footprints:The TTC gives you equal or better results with a compact footprint*Achieving repeatable measurements is difficult in an anechoic chamber:The TTC guarantees the microphone and loudspeaker positions*Anechoic chamber accuracy suffers at low frequencies:The TTC is capable of measuring below 20 Hz*Results are not transferable between most test chambers:The TTC meets international standards IEC 60268-21:2018 & IEC 60268-22:2020*Most chambers are difficult to calibrate and awkward to use:The TTC is calibrated and is ready to interface to your microphone and analyzer
-
product
Anechoic Chamber
Wedge:The acoustic absorptivity of sound-absorbing materials used in anechoic chamber must be greater than 0.99. In anechoic chamber, gradient absorption layer, wedge or conical structure are often applied with glass wool and flexible foam as its sound-absorging materials. Anechoic Door: The design of rotatable door can affect the whole function of anechoic chamber. Therefore, it's crucial to combine steel plate and sound-absorbing cotton in the door, which is exactly our design.Acoustic Insulating Material:Applying high-density materials to enclose external noise. Damping materials: Using spring, rubber and cotton to enhance damping capacity.The Anechoic Chamber conforms to GB/T 6882-86 and ISO 3745 specifications.
-
product
Anechoic Chamber
Beijing KeHuan Century EMC Technology Co,.LTD
(7m × 4m × 3m) RF shielding EMC laboratory (anechoic chamber) is constructed by attaching ferrite tiles and microwave absorbing materials after the RF shielding room is built (7m × 4m × 3m) The simple 3m test distance EMC laboratory can perform EMC tests in the frequency range of 30MHz-18GHz.
-
product
RSE Wireless EMC Spurious Emission
TS8996
The R&S®TS8996 RSE test system is designed for EMI and radiated spurious emission testing on wireless devices in semi-anechoic or fully anechoic chambers. The modular design makes it easy to extend the system to include new communications technologies. Typical devices under test include mobile phones or radio sets along with radiated measurements of other short-range devices. Standards require a wide range of test setups and a wide and high frequency range (up to 40 GHz). ESW or FSW frequency ranges are extended up to 325 GHz with option B21 using receive units TC-RSE for 5G FR2. Dedicated RSE test routines are also covered for this frequency range.
-
product
Compact EMS/EMI Test Platform
CEMS100
Setting up an EMS/EMI test system is a very complex process requiring significant investment. The steps involved include custom planning, design, installation and configuration of various components and standalone instruments as well as the RF shielded anechoic chamber. Rohde & Schwarz offers the standardized R&S®CEMS100 test platform that is the company's first flexible, reliable and cost-effective off-the-shelf solution for radiated EMS measurements in line with IEC/EN 61000-4-3.
-
product
Radiated Power Measurement
One of the most important properties of a wireless device is how much it actually radiates, how efficient is the antenna.This is typically measured in an anechoic chamber (at an expensive test lab). Another, time-consuming and inaccurate, method is by walking around in a free field and test the communication distance.
-
product
Compact Anechoic Chambers
If you have mmmwave or THz antenna phased-array that require Over the Air measurements, MilliBox has the equipment and tools that you need. With the help of MilliBox compact anechoic chamber system, you can plot radiation pattern , collect data from those plots, and assess your antenna performance easily and precisely.
-
product
Calibration
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
product
Anechoic Chamber
EMC-3
A 3 meter test range ensuring fully compliant Emission and Immunity testing. Ferrite and hybrid pyramidal absorbers are combined in a unique pattern within a SmartShield high performance chamber. Operating at a 3m test distance, this chamber is compliant to CISPR-16 with a measurement zone diameter of 1-2 meters.
-
product
Broadband Antenna
Vivaldi
The dbDIRECT Broadband Antenna features a broad frequency range of operation, high gain, small form factor and directional radiation pattern, making it highly attractive for widespread use in test and measurement of emerging wireless technology devices and radars. Contrary to conventional Vivaldi antennas limited to operating only at higher frequencies, the dbDIRECT Broadband Antenna design is optimized to operate at a frequency as low as 700 MHz up to 6 GHz. This lightweight and compact antenna design provides excellent matching over a broad frequency range.The antenna is designed to be placed in a DVTEST's portable anechoic chamber such as the dbSAFE enclosures for OTA (Over the Air) testing of DUTs. The antennas can be mounted in fixed positions to facilitate repeatable results. When used in conjunction with a rotary positioning mechanism, customers are able to detect the highest point of power sensitivity for enhanced accuracy and repeatability in measurements. In this configuration, both the antennas and DUTs can be positioned in order to facilitate the measurement.
-
product
Production Line Acoustic Test Chamber
PLATC
The Production Line Acoustic Test Chamber from GRAS is designed for quick and qualified acoustic test of cell phones, tablet PCs, Bluetooth speaker systems etc., including frequency response, THD, Rub & Buzz and microphone test using optional sound source. The chamber has a number of connections for injecting test and control signals to the test object (DUT).Benefits include:Repeatable testing and reliable dataEasy open/close for quick and safe change of DUTFlexible test jig for easy adjustment to new DUTFlexible microphone mounting for both front/backside speakers as well as edge-mounted speakersHigh quality, high sensitive 1/4” CCP measurementmicrophone included (G.R.A.S. 46BL)Individually calibrated frequency response** Compared to reference measurement in anechoic room
-
product
EMC Test & Measurement Solutions
MVG provides anechoic chambers and absorbing materials for antenna and EMC measurement and testing as well as RF and EMP shielding. Our SmartShieldTM modular shielding and precision cut and coated absorbers are designed with the flexibility to meet specific customer requirements. Our knowledge gained from over 30 years of experience ensures the high quality and durability of our products and the expertise from our team.
-
product
Tapered Anechoic Chamber
It’s nearly impossible to perform VHF/UHF measurements in a rectangular chamber. In the 1960’s Emerson determined that tapering one end of an Anechoic Chamber would cause the chamber to act like an indoor ground reflection range.Tapered Chambers work very well at the lower frequencies. Their design forms a uniform illumination across the test region. The tapered end of the chamber forces the wall images close together forming a source antenna array. Tapered Chambers are usually a less expensive option compared to rectangular antenna measurement chambers or compact ranges.