Filter Results By:
Products
Applications
Manufacturers
BH Loop
-
product
Material Science Laboratory Instruments
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
product
Fluxmeter
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
product
Magnet Tester
H30 Series
AlmiCo, Ferrite, NdFeB, SmCo5, Sm2Co17 magnets are tested and their B-H and MH loops are plotted using Ferrites India make H30 Series hysteresis loop tracers. The complete system consists of a magnetizer to magnetize the test piece, an electromagnet and a BH Loop Plotter. Magnets with coersivity as high as 13 kOe and more can also be tested.
-
product
B-H Analyzer
SY-8218 / SY-8219
Soft magnetic components made of ferrite play an important role in electric components as they are used in a broad range of applications from low-frequency applications such as yokes for micromotors, to high-frequency applications such as flyback transformers, deflecting yokes, high-frequency transformers and magnetic heads. In actual operation, these magnetic components display characteristics different from DC magnetic characteristics or characteristics measured with an LCR meter.
-
product
B-H Analyzers
Precise and accurate core loss measurementIwatsu's B-H analyzers which hiring CROSS-POWER method (IEC62044-3)enable precise and highly accurate measurement embedded minimized phase error integration on frequency spectrum with current detecting resisters and compensation on detecting circuit with full compensation on amplitude and phase characteristics.
-
product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
product
Single Loop Controller
3200
The instrument has the largest red or green digital display in a 1/32 DIN package. In addition to the red or green display the 3200 benefits from three additional multi-colour LEDs to indicate process, alarm and configuration statuses.
-
product
Loop Tack Tester
Loop Tack Tester is applicable to measure the tack property of adhesive tapes, pressure-sensitive adhesives (PSA), and adhesive materials according to ASTM D6195.
-
product
Single Loop Controller
1460
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
product
Current Loop Expansion Kit
OP-SB85C
This expansion kit supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
Active Dual Loop Antenna
KH30936
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
product
Loop Impedance Tester
CZ20054
Australian and New Zealand standards mandate testing of fault loop impedance on circuits not protected by RCD's, both at installation and after maintenance. The CZ20054 Loop Impedance Tester conducts earth fault loop impedance and prospective short circuit current (PSC) tests. The Aegis Loop Impedance Tester takes the confusion out of loop/psc testing by providing an automatic wiring check upon connection and single button operation.
-
product
Hysteresis Loop Tracer
MESA
The MESA is the only hysteresis loop tracer on the market that can make measurements in the frequency range of 10 Hz and below. Competing units operate with more-easily generated 60 Hz drive fields, and can have errors of as much as 30% in coercivity (Hc) measurements.
-
product
Micro-Ohmmeter and Loop Resistance Tester
LRT 6000
LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.
-
product
Loop Antennas
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
product
Loop Calibrator
6500 LC
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
product
Loop powered Moisture Analyzer
PLMa
Multifunctional Multi-Purpose Cost Effective, easy-to-use dew point sensor, dew point probe
-
product
Friction Flow Loop System
Friction Flow Loop System is used for testing the effects of friction reducers by circulating at high rates through different pipe diameters. Friction Loop designs vary based on the application required.
-
product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
product
Phase Locked Loop with Integrated VCO
PLL with integrated VCOs provide local oscillator sources and clock sources for communications (COMMS) , test and measurement (ETM) and aerospace/defense (ADEF) applications. ADI's PLLs with integrated VCO portfolio includes both narrowband and wideband parts, supporting frequencies up to 13.6GHz. Our PLLs with integrated VCO, as well as our full PLL portfolio including integer-N and fractional-N PLLs, feature best-in-class performance for phase noise, jitter, and spurious, and also feature high levels of integration in small form factor packages.
-
product
Open And Closed Loop Inverters
VFD
Inverter products support the energy-saving operation of equipment and machinery with fine speed control.
-
product
Loop Meters
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
IntelliPoint RF - Loop Powered Level Switch
The IntelliPoint Loop Powered Two Wire provides a capacitance probe level switch with current output and “On-Board” self-diagnostics to ensure reliability and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
product
Level Control Loop Trainer Model
ULP-24P & ULP-24C
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Level Control Setup comprises of acrylic measuring tank fitted with Level transmitter, control valve, I to P converter, source tank with water pump and necessary flexible piping for water circulation. The system is mounted on a table top powder coated metal frame. Level transmitter is of capacitance or DPT type sensor. The electronic panel comprises of ADC and DAC card with RS-232 interfaces.
-
product
Local Loop Simulator 128 Channels
458-CC-16/458-CM
FEATURES: Accepts 1 to 16 Line Modules; User-Friendly Interface; Multiple Configurations; Field-Upgradeable Software; One-Year Warranty/Calibration. The 458 Series 16-slot Chassis, which consists of the 458-CC chassis and one of three control modules, provides a wide variety of configurations through use of up to 16 plug-in Line Modules.