Filter Results By:
Products
Applications
Manufacturers
Chart Recorders
Input a record to paper.
See Also: Recorders, XY Recorders, Fault Recorders, Disturbance Recorders, High Speed Data Recorders, Event Recorders, Transient Recorders, Temperature Recorders, Data Recorders
- TEAM SOLUTIONS, INC.
product
HandyScope HS5 + SureConnect: 50 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 5MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS5-055XMS-W5
The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 50 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.
-
product
16 or 32 channel Digital to Analog Converter
LS-71-P
The LS-71P PCI D/A Converter (DAC) board provides high speed analog outputs of PCM decommutated data allowing real time data displays using strip chart recorders or similar devices. The LS-71-P board is designed to be used in conjunction with the Lumistar LS-50-P Multifunction PCM Decommutator boards and uses an over-the-top communication bus directly from the decom to the DAC to avoid any glitches in the analog outputs due to PCI bus activity. Direct “mailbox” type access is also provided to allow the user to send information through the PCI bus to the DACs. The DAC board design allows 2 LS-50-D Multifunction decom boards to be used with a single DAC board allowing tagged data from either data stream to be directed to any DAC channel. An optional LS-71-DB Word Selector Daughterboard allows two additional data streams to be monitored with the ability to select channels from 4 data streams to be displayed on any DAC channel. The design incorporates an extremely large memory (more than 200,000 16-bit words) used as a lookup table allowing linear or non-linear EUconversions with constant delay regardless of the number of polynomial coefficients required. Standard product supports a single decom, however, dual decom support is available as an option.
-
product
Mission-Critical Chart Recorder
EV-5000
The EV-5000 is ideal for mission-critical data acquisition applications where digital storage and paper printouts are required. Engineered to be a direct replacement for the field-proven Everest® series of chart recorders from Astro-Med, the EV-5000 eliminates the need for costly retrofits and provides the same high-quality charts, easy data review and permanent records. Print recorded data on standard 16.3” (414 mm) Z-fold chart paper.
-
product
GHI Level-1 Software
WinCAT
# Waveform Tags: Movable text-based Tags can be attached to any portion of a waveform. These tags will appear on reports, and are saved with archived waveforms. # New View Modes: Scroll through a maximum length raw data file using Windows scroll buttons. This feature allows viewing and fast isolation of points of interest of an entire waveform file that is otherwise too long to fit on the screen, performing much like a chart recorder display. Multiple data windows can sized to fit the display area, or 'tiled' for easy access.
-
product
Averaging Extensometers for ASTM D5656 Shear Tests
Model 4013
Jinan Testing Equipment IE Corporation
The Model 4013 extensometer meets the requirements of ASTM D5656 for measuring the strain properties of an adhesive in shear. It uses different contact point spacing compared to the extensometer shown in D5656. This makes it much easier to mount and eliminates the slippage problems associated with the design shown in the ASTM standard. The Model 4013 is available with all of Epsilon’s temperature configurations. It has a 3.0 mm (0.12 inches) full scale measuring range. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 4013 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Axial Extensometer
Model 3542
Jinan Testing Equipment IE Corporation
These extensometers are designed for testing a wide range of materials, including metals, plastics, composites and ceramics. All will work in both tension and compression. The dual flexure design makes them very rugged and insensitive to vibrations, which permits higher frequency operation.They come standard with Epsilon’s quick attach kit, making it possible to mount the extensometer on the test specimen quickly and easily with one hand. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The Model 3542 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.For gauge lengths 100 mm (4 inches) or greater see Model 3542L.
-
product
Fracture Mechanics Clip-On Gages
Model 3541
Jinan Testing Equipment IE Corporation
The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 (the replacement for E813 and E1737) for JIC and R-curve determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configurations). In addition, the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organization’s test methods. Clip-on gages can be used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen.The Model 3541 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Field Strength Meter
FIM-72A UHF
The Model FIM-72A is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-72A is suitable for practically all types of RF emission measurements in the 450 MHz to 960 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and meter dynamic range of either 20 dB or 60 dB. A dc analog voltage, proportional to meter indication, is provided for driving a chart recorder or similar device. A leveled output from the calibrating generator is available for measuring cable insertion loss, filter response, amplifier gain, VSWR, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.
-
product
Bolt Extensometers for Proof Load Testing
Model 3565
Jinan Testing Equipment IE Corporation
The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Chart Recorders
device that records an electrical or mechanical input trend onto a piece of paper (the chart).
-
product
Paperless Recorders
View real time display of data in a variety of formats, digitally transfer and store all results. If you want to learn more about chart recorders you can read our guide on this link.
-
product
Thermocouple Thermometer, Dual Input / Analog Output
871A
Industry''s leading handheld thermometers that feature analog outputs for use with chart recorders or computer I/O cards, the 870 series has dual thermocouple inputs and respective linear analog outputs which produce 1mV/C or 5/9 mV/F in the 200 ranges and .1mV/C or 5/90 mV/F in the other ranges. The Model 871A uses Type K thermocouples to measure a temperature range from -40 to 1999F (-40 to 1370C) and the Model 872A uses type J thermocouples to measure from -40 to 1400F (-40 to 760C).
-
product
Temperature/Humidity/Dew Point Circular Chart Recorder
The Temperature/Humidity/Dew Point Circular Chart Recorder uses a red pen to track temperature and a blue pen to track humidity, permanently recording these measurements on a 6-inch (165mm) diameter paper chart. Power is supplied to the temperature recorder through a 110V AC 50/60 Hz plug-in adapter for Model 14013 and a 220V AC adapter for Model 14014. External power may be supplied from any 12V DC source such as automotive, marine or other battery.
-
product
Field Strength Meter
FIM-71 VHF
The Model FIM-71 is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-71 is suitable for practically all types of RF emission measurements in the 45 MHz to 225 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and a meter dynamic range of either 20 dB or 60 dB. A dc analog output voltage, proportional to the meter indication, is provided for driving a chart recorder. A leveled output from the calibrating oscillator is available for measuring cable insertion loss, filter response, amplifier gain, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.
-
product
Smart Profiling
The average thermal profiler on the market operates like the old chart recorder migrated onto a PC. It is a passive data acquisition unit that informs the user of the PCB profile. Smart profiling goes beyond that into the realm of data intelligence. Based on your input, the profiler tells you where you are, where you want to go, and how to get there. Intelligent databases provide such information without even needing to run a manual profile! The data can be linked and shared with all authorized personnel.
-
product
High-Power Battery Charge/Discharge Test System
9200 Series
12 to 144kW with either 120 or 600 V Power Modules Fast voltage, current and mode transition times Digital measurement system with hi-res waveform capture and digital chart recorder Custom waveform/profile generation Multiple safety features to protect battery Touch-panel manual interface Customer's own or NHR Enerchron™ Test Executives
-
product
High Temperature, Low Strain Capacitive Extensometers (1200 C or 1600 C)
Model 3648
Jinan Testing Equipment IE Corporation
These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. They mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The overall design reduces any influence from common lab environment vibrations.The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. These units are made to order in many different gauge lengths and measuring ranges.The extensometer comes with a signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically. They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.
-
product
Wet/Wet Differential Pressure Transmitter
647
Monitor differential pressure in air/liquid flow systems, HVAC automation, pneumatic systems and process control with the Series 647 Wet/Wet Differential Pressure Transmitter. Units are temperature compensated and provide a 4 to 20 mA output signal which can be interfaced with chart recorders, data loggers and computerized monitoring and control systems.
-
product
High Elongation Extensometers
Model 3800
Jinan Testing Equipment IE Corporation
The main body of this unique extensometer remains stationary during testing, held in position by the adjustable magnetic base included. Only the very light, small traveling heads move as the sample elongates during a test. These attach to the sample with small spring clips. Each head pulls a cord out from the extensometer as the head moves. These models use high precision, low friction potentiometers, and, as a result, have a wide range of factory selectable outputs. The extensometer is driven by an excitation voltage and has output proportional to the input. They can be provided with high level outputs (approximately 2-8 VDC) or ones that mimic strain gaged devices (2-4 mV/V). When set to mimic strain gaged extensometers, the Model 3800 can be used with virtually any signal conditioning electronics designed for strain gaged sensors. The potentiometers employ a hybrid wire wound around conductive plastic, which provides excellent long term stability. The output from the extensometer is readily interfaced with most existing test controllers, and may be directly input to data acquisition systems and chart recorders. Please let us know at the time of order what type of output and connector you require.
-
product
Electronic Circular Temperature Chart Recorder
The Circular Temperature Chart Recorder’s external stainless steel probe allows you to measure the temperature of air, gas, liquids and semi-solids. The temperature chart recorder has a quartz clock movement, motorized chart advance and temperature accuracy of ±2°F (±1°C). The chart recorder comes in °F or °C models and runs on 120V or 220V AC, 50/60 Hz. A rear compartment houses 8 AA alkaline batteries, providing up to 48 hours of continuous recording in the event of a temporary power loss.
-
product
Bi-Axial or Axial Averaging Extensometers
Model 3560
Jinan Testing Equipment IE Corporation
This extensometer is ideally suited for testing anisotropic materials such as advanced composites as well as for general purpose tests like determining Poisson’s ratio. The Model 3560BIA uses a design unique to Epsilon, where the knife edges remain parallel during the displacement. This approach greatly reduces crosstalk between axes and allows use on round or flat specimens with equal ease. These extensometers are very easy to mount. Integral springs hold the unit on the test sample. The parallel multiple flexure design makes these units very durable.The Model 3560AVG reads axial strain only as a single averaged output. It may also be supplied with two independent outputs, one measurement from each side of the specimen. This set-up is most commonly required when an indication of specimen bending is desired. The second version, the Model 3560BIA, includes both the averaged axial strain and the transverse strain. Again, this may also be configured as dual independent axial readings, which results in a three channel extensometer.The Model 3560 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Extensometers for Indirect Tensile Testing of Asphalt
Model 3911
Jinan Testing Equipment IE Corporation
For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
High Temperature Diametral Extensometers (1000 C)
Model 3580
Jinan Testing Equipment IE Corporation
This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Chart Recorder & Data Acquisition
MRC7000
The MRC7000 Recorder/Controller is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables from a variety of inputs. Record and control functions, alarm settings and other parameters are easily configured via the keys on the front cover and self-prompting displays. All user entered data can be protected against unauthorized changes via the MRC7000 Enable Mode security system.
-
product
Circular Chart Recorders
With over 100 years experience in the industry ABB’s circular chart recorder offering is world class. Our range is extremely easy to use, offers up to four pens, NEMA 4X and IP66 environmental protection, integrated PID control and data logging.
-
product
Miniature Axial Extensometers
Model 3442
Jinan Testing Equipment IE Corporation
Weighing as little as 8 grams, these miniature extensometers are designed to have very low operating force with minimal specimen influence. All use an improved version of Epsilon’s dual flexure design which makes them very rugged for their size. With a module height of 15.2 mm (0.6 inches), they will fit in the limited space between grips that is typical with small test samples. Gauge lengths can be as short as 3 mm or as long as 50 mm. A newly designed gage setting pin and assembly allows the gauge length to be set accurately and repeatably to ASTM and ISO requirements for all gauge lengths. Reengineered quick attach wire forms provide simple and secure specimen attachment. Wire forms for round and flat specimens are included, as well as flat, 3-point, and vee knife edges. The wire forms may be removed to enable mounting using elastic bands or springs. A tethering attachment point provides fall protection and enables counterbalancing of the extensometer’s weight when testing delicate specimens.Model 3442 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller and Epsilon will equip the extensometer with a compatible connector wired to plug directly into the controller. For systems lacking the required electronics, Epsilon can provide a variety of solutions for signal conditioning and connection to data acquisition systems, chart recorders, or other equipment.
-
product
Hybrid Paper Recorders
Record on paper and digitally simultaneously for easy reading now, and archiving for later. Omega offers circular or printout form chart recorders with a variety of input types for your application.
-
product
Graphic Data Logger
IM2000G series
We are involved in offering of IM2000G series of Graphic Data Logger. TFT LCD screen display which exhibits graphics in varying color texts. The loggers designed by us display on line trend graph and also historic graph data. These loggers are direct alternatives against old paper recorders or paper pen type strip chart recorders. The logger can also be termed as paperless chart recorders.
-
product
Rugged, Long Gauge Length Extensometers
Model 3543
Jinan Testing Equipment IE Corporation
With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Data Acquisition
Data Acquisition And Control Software offers complete control over the temperature and pressure schedules of oilfield laboratory instruments from a personal computer. Digital Chart Recorders provide secure data storage and digital backup of critical test data. Previously sold as ancillary equipment on all Chandler Engineering HPHT cement consistometers, pen and paper chart recorder technology is rapidly becoming obsolete as industry demands change.
-
product
Chart Recorders
A chart recorder is an instrument used to record various process and electrical signals. The most traditional chart recorders record data on paper. The paper is passed under a pen and the pen is deflected in proportion to the signal. The result is a graph or chart of the data.