Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Wide Current Range Multiplexer Module, Single 12-Channel, 2-Pole
40-514-105
The 40-514-105 (PXI) and 42-514-105 (PXIe) are low density multiplexers in single 12-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
Multifunction Electrical Installations Meter
MPI-525
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
product
Remote Indicators
ABB field indicators provide a convenient way to access the field instruments data when they are located in remote or difficult to access areas. Powered directly from the 4-20 mA current loop, they require minimal effort to setup.
-
product
Dual High Speed Power Supply
VX4620
Dual high speed power supplyLow noise linear output stage with 200 Vpp and 1 AProgrammable bipolar voltage and positive/negative current limitsStable control loop even on long load linesAuto sensing featureProgrammable slew rateProgrammable over GPIB, USB or RS232Fast rise and fall times due to integrated sink capability
-
product
Downloading Multifunction Tester
ET4500
The new ET4500 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.
can be used to carry out 3 wire earth testing and has on board memory to store and download all installation test results for documentation.
Everything about the new ET Series has been designed to save time and make testing easier.Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .Supplied with a full range of accessories.
-
product
Split Core Hall Effect DC Current Sensor
CYHCT-C2TC
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
Anti-Tamper Sub-Assemby (DC Immune CTs + Potential Transformer)
Shanghai Powoo Industry Develop Group Limited
ATS can provide double loop current sampling and power supply for measuring unit of static meter. When load voltage, static meter can in normal condition without single-channel current.
-
product
NI-9266 , 8-Channel C Series Current Output Module
785046-01
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
product
Open Loop Current Sensor
K03
The K03 series is a current sensor based on the Hall effect. It enables the electronic measurement of direct, alternating or pulsed currents as well as their combinations with galvanic separation between primary (high current) and secondary circuits.
-
product
PCI 8 Form C Relay Output / 8 Isolated Input Digital Interface
8011
The 8011 digital I/O interface provides 8 optically isolated inputs and 8 Form C relay outputs. The inputs protect the PC and other sensitive equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide higher current capabilities (up to 2A) and are optimized for 24V operation.
-
product
CompactPCI
CPCI-ADDA
The CPCI-ADDA module offers a complete solution forhigh performance data acquisition applications. Boththe ADC’s and the DAC’s use 10 mS converters thatwill support up to 100khz signals. The CPCI-ADDAsupports P.I.D. loop closure frame rates of up to 4 KHzper channel. The CPCI host can download gain andsetpoint changes on the fly. The CPCI host can readback the current values for feedback, error, setpointand output drive on each channel. The local DSPprocessor can be used for data processing such asdigital filters and FFT’s. The DSP can also be used asa waveform generator to drive the 16 bit DAC.
-
product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
product
Low Power Potentiostats
Potentiostat Wenking MP 04T, max. current 400 mA, max. voltage 25 V, output power 10 W, reference electrode input 1012 Ohms, slew rate 10 V/ µs, 1 control input, floating current output, buffered potential output, control range ± 10 V external, internal control voltage source ±2 V, rise time constant (closed loop, ohmic load) 1 µs typ., dimensions 165 x 105 x 165 mm (w x h x d), weight 1.4 kg
-
product
Resistance Tester With Leakage Current (Loop Current)
GT00WD00ZY
*screen display*Double protection insulation*Non-contact measured resistance, safe, fast
-
product
Linear regulated power supply with thyristor pre-regulation
NTN
High efficiency Short circuit proof and unlimited operation with full current in short circuit condition voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked 4 digit DVM for voltage and current (for table-top models) Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals Parallel and series connection possible Suitable for inductive and capacitive loads for 700 W nominal power and higher, limitation of inrush current on switching on Interlock loop to monitor the external load and internal loop as a standard for three phase units Elapsed-hour meter as a standard for three phase units
-
product
Electromagnetic
Promis 10
The Promis device is a multi-frequency, multi-spacing 3 component slingram type EM System for sounding and profiling the soil. This system features a transmitter loop to produce a primary magnetic field that will induce eddy current in conductive materials. These eddy currents will generate a secondary magnetic field that will be measured with the receiver loop. This system measures the in-phase and the out-of-phase components of the secondary magnetic field.
-
product
4-Port Serial Interface, Modular, With/Without Optical Isolation, 3.3V
CPCI-7500
*This Model has a 37-pin D-Sub male connector*RS232, RS422, RS485, 20 mA Current Loop*Modular structure through SI modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer, common interrupt*Transfer rate programmable up to 115,200 Baud*Option: up to 1 MBaud for RS485 and RS422*Automatic direction recognition for RS48*Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)*Transmission mode asynchronous, full, half duplex*Transfer rate: progr. up to 115.2 kBaud up to 1 MBaud on request*Protocol: 5, 6, 7 or 8-bit character 1, 1? or 2 stop bits*Parity: even, odd, none, mark or space*Interrupt lines: automatic through BIOS
-
product
Battery Charge And Discharge Test System
9841
*Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data
-
product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
product
TEST BOX
6280 TB
Standard Electric Works Co., Ltd
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1
-
product
Closed Loop Hall Effect Current Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
product
Intelligent Transmitter with Digital Indication
LEO 3
KELLER AG für Druckmesstechnik
LEO 3 is a micro-processor based transmitter with digital double-display for pressure (top display) and for the output signal (bottom display). The display is powered from the 4...20 mA current loop. Functions:
-
product
12 D/A Outputs (±10 VDC or ±25 mA)
DA1
The DA1 module features 12 independent D/A output channels with a full-scale range of ±10 VDC at ± 25 mA (max). The DA1 provides either voltage or current control loop modes that are programmable for the particular application. The DA1 module also offers external trigger/synchronization signal (RS422/485) capability, which provides/accepts a trigger signal to/from other module(s).
-
product
Current Sense Amplifiers
Analog Devices’ current sense amplifiers offer excellent performance for a wide array of automotive and power management applications. These devices accurately amplify small voltages in the presence of large common-mode voltage, and provide high bandwidth, as well as level shifting and bidirectional capability. Excellent dc and ac accuracy over a wide temperature range from –40°C to +125°C minimizes errors in your measurement loop while not sacrificing on cost and package size.
-
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
product
Opto-Isolated Current Loop Signal
4029
SPECTEC Innovative Sensor Solutions
SPECTEC's Model 4029 digital opto-isolated current loop signal conditioner prevents ground loops and interrupts any galvanic signals riding on magnetic speed sensor's output signal.. This signal conditioner converts magnetic, variable reluctance and inductive sensors' sinusoidal signals into a 4-20 mA output suitable for interfacing with process control units, dataloggers, flow controllers, and computers.
-
product
Multifunction Meter for Electrical Installations
AMPI-530
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
product
PXI Analog Output/Current Loop Simulator Module - 4 Channel
41-765-004
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Industrial 4-20mA Driver
Analog Devices portfolio of leading industrial d/a converters and drivers addresses the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
product
Loop Meters