Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-212
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module
778572-12
7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
product
PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module
778572-14
7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
product
Variable Power Supply
VS3
The VS-3 power supply is a very convenient portable, non-isolated “variable source” from 0 volts to 150 Vac or 0 volts to 150 Vdc and rated for up to 3 amps, thus the name VS-3. It is comprised of an illuminated voltmeter that reads to the first significant digit, AC variable system output voltage, DC variable system output voltage, logic output voltage and one sense (continuity) contact monitoring points. Banana jacks for connection of test leads are spaced at intervals that allow the use of dual banana test plugs if desired. The VS-3 is protected by two levels of overcurrent protection; AC input, and ground fault protection by a GFCI. All circuitry is housed inside a custom designed case made from 16 gauge steel. An Internal fan dissipates heat buildup and exhaust through louvered side vents built into the case. The carrying handle is designed with a “spring return to rest” position and is padded for comfort. The case has been sized for optimum portability and is balanced from the handle during transportation. The case has a powder coated finish that is scratch, chemical and weather resistant. Rubber padded feet support the case when in the upright position and a convenience receptacle is located on the side of the case. A unique feature of the VS-3 is that it contains “Magnet Packs” on the back of the case. These “Magnet Packs” can support the VS-3 and allow it to “hang” from any magnetic metal surface. The VS-3 can be powered by our UPS system, eliminating the need for an extension cord. The ability to magnetically attach the VS-3 near the source of connection and eliminating the need for an extension cord makes the VS-3 a “must have tool” for technicians.
-
product
Trailer Light Testers
Pro-Check 725
Pro-Check trailer light testers with advanced electrical diagnostics are rugged, lightweight, and economical. They independently test each electrical circuit on a trailer to ensure proper connectivity. The Pro-Check identifies each specific type of electrical wiring fault. Lite-Check’s patented active diagnostic system takes the guesswork out of identifying trailer light and electrical problems. The Pro-Check commercial trailer light tester with electrical circuit diagnostics, not only identifies faults, but the specific circuit the fault is on. Faults are identified as “Open Circuit”, “Open Ground”, “Short” (w/all circuits identified), or “Chassis Ground”. Audible alarms alert technicians to found electrical faults.
-
product
PXI BRIC4 FIBO Matrix Dual 93x4 2pin brkout
40-592A-013
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
AC Current Transformers
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers. Various outputs include 5 amp secondary, high turns ratio voltage outputs for both wire leads and pcb configurations. Our products are UL Recognized for both US and Canada.
-
product
Automatic Oil Insulation Test Kit
The test kit is fully automatic and has the facility forAuto/Manual selections. The operator simply needs thesample in the test vessel & selects the required test. Testingcan be done as per many international ( IEC & Europeanstandards ) which are programmed into the instrumentmemory . Stand time, Stir times & Rate of rise of appliedvoltage can be selected in Custom Mode also , one setof such selected mode can also be stored in the memory. In addition to the above set can also perform withstand test(proof) tests. In this test the set allows the set voltage to pre-set value & hold for one minute to see if breakdown occurs. The backlit LCD is used for user friendly operationsduring the test process. It also display fault condition messages such as open ground and cover open . All the user selected programmes are chosen through(4x3) key pad.The test results can be printed along with with test type, date, time, breakdown test voltage, averages and deviations. Voltage value can be measured & printed with a resolution of 0.1kV. In reprint option it is possible to have number of printouts for the last test. For each test the readings are recorded and stored in memory.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Electric Shock Protection Analysis
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
PXIe-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module
780587-14
PXIe, 7-Channel, 40 A PXI Signal Insertion Switch Module—The PXIe‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXIe‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs).
-
product
Earth Fault Detector
K-3838
Kongter Test & Measurement Co., Limited
Kongter’s K-3838 earth fault detector is the updated model which is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the reliability of your electrical equipments. Our unique technique makes it safe and fast to handle earth fault in DC systems that are working online.
-
product
PXI BRIC8 FIBO Matrix Dual 93x4 2pin brkout
40-592A-113
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
DC Fault Tester
HBD-81
The HBD-81 DC Portable DC System Ground Fault Locator designed for DC fault testing. This equipment utilizes the principle of DC current differential detection and incorporates fast FFT (Fast Fourier Transform) technology for detailed analysis of the amplitude-frequency characteristics of the test signal. By balancing the safety and sensitivity aspects of DC ground fault locating, it effectively resolves the conflict between the two.
-
product
Ground Fault Locator
K-3837
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
product
PXI BRIC8 FIBO Matrix Dual 100x4 3pin brkout
40-592A-105
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
PXI 10A Fault Insertion Switch 6-chan 2-bus
40-192-012
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
product
PXI BRIC4 FIBO Matrix Dual 40x4 3pin brkout
40-592A-002
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
5mA High Accuracy Ground Fault Detector
HA-GFD
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
product
DC Earth Fault Locator
GFL-T + GFL-R
The DC Earth Fault locator is suitable to test the DC Battery System and Trace Ground Faults. The system is suitable for Power Plants, Sub-Stations upto 765KV and other industries. The system is highly capable in tracing and pin pointing the DC earth faults in a live system without requiring any shut downs. The receiver sensitivity of 1mA and better is capable to trace most complex fault.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Air Core Neutral Grounding Reactors
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
product
Ground-Fault Detectors for Ungrounded Systems
Early detection of ground faults on ungrounded systems allows critical systems to remain online while faults are identified and resolved. By continuously monitoring the system's insulation resistance, Bender's ground-fault detectors can provide early indication of both immediate and trending ground faults before leakage current may be of concern.
-
product
Voltman True RMS Industrial Safety Voltmeter
125
If you need a continuity function or harmonics are a problem then the Voltman TRMS is for you. Non sinusoidal waveforms from variable speed motors cause problems for most meters but the Voltman TRMS meter is specifically designed to produce accurate and dependable readings of distorted waveforms. When there is no voltage present the unit automatically tests for continuity, ground faults or shorts.
-
product
Ground Earth Resistance Tester
2678X
Shenzhen Chuangxin Instruments Co., Ltd.
Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.
-
product
Fault Locator
VM-510FFL+
Finding the location of an underground cable fault just became easier with the VM-510FFL+ Standalone A-frame locator. Now locating a suspect cable and finding the fault can be done with the VM-510FFL+ and a compatible transmitter. There is no longer a need for a separate utility locator with cables connecting to it. After connecting a compatible transmitter to the line and placing it in a Fault-Find mode, use the simple to operate four button controls of the VM-510FFL+ to locate and stay on the cable path while pinpointing the sheath or ground fault.
-
product
Ground Fault Finder
FST-JD200 DC
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
product
Bus Bar Protection
BUS1000/2000
The BUS 1000/2000 is a solid state, high speed protectionsystem for the detection of phase-to-phase andphase-to-ground faults on bus bar installations. It can beused to protect high voltage bus bar installations of anyvoltage.
-
product
PXI BRIC4 FIBO Matrix Dual 60x4 3pin brkout
40-592A-003
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
Under Ground Cable Fault Locator
Widely used in electrical and power generation sector for testing underground cables in order to detect any fault.