Filter Results By:
Products
Applications
Manufacturers
Harmonic
Sinusoidal component of a perodic wave or for a sine wave, it is an integral multiple frequency of the wave.
-
product
Harmonics and Flicker Testers
complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*.
-
product
Three-Phase AC Power Sources
AC6900 Series
Keysight’s AC6900 Series AC power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument. You can easily produce DC power, either alone or as a DC offset to an AC waveform, in a compact form factor.
-
product
NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783311-01
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.
-
product
DP Range Broadband Power Amplifiers 10 kHz - 250 MHz
DP Series
Class A solid stateBroadband (instantaneous single band): 10 kHz 250 MHzTypical output power : 1000 W CWLinear output power (1 dB compression) guaranted with harmonics <-20dBc:P1dB>600 W and H<-20 dBcAir cooling: self contained fansCan operate in full mismatch conditions without damageReliable, efficient and robust19" Cabinet on wheels3 years standard warranty
-
product
Capacitors - Power - Heavy Current (ESTA)
Vishay ESTA is one of the few manufacturers to offer a complete range of power capacitors. These cost-effective devices for harmonic control, energy savings, and voltage stabilization are highly reliable and environmentally safe, and can be used under the most rugged conditions. Vishay ESTA power capacitors address a wide range of energy-generation applications. Their “green” applications include energy generation in on- and off-shore wind turbines and solar power plants.
-
product
Subnanosecond Lasers
Up to 50W of power at 532nmSub ns Pulse Widthspecifiable from 150ps to 1nsRepetition rate from 1kHz to 20MHzExcellent beam quality (M2<1.3)Closed loop chilledSmall compact all-in-one form factorDiode pumped technologyFundamental and other harmonic options available
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
PCI I/O Module for Sound and Vibration
JSV-4461-PCI
2-channel ICP analog voltage inputMaximum sample rate: 204.8KS/s; simultaneous acquisitionAnalog-to-digital converter: delta-sigma, 24 bitsPhase Accuracy < 0.05deg@10KHzMaximum analysis bandwidth:96 KHzInput range from ± 42.4 V to ± 316 mV Coupled Mode: AC, DCDigital filter: user-defined low pass, high pass, band pass, band stopDynamic range: 118 dB; harmonic distortion: -107dB; channel crosstalk: -138dBICP current: 0-4 mA, optional 2-channel analog output range: ±10 V; update rate: 204.8 kS/s
-
product
Three-Path Diode
NRPxxS/SN/SN-V
The R&S®NRPxxS/SN power sensors use three separate diode paths, each operated in the optimum detector range. As a result, the average power can be determined with high accuracy independent of the modulation type. Measurement results are hardly affected by interfering signals or harmonics.
-
product
RF/Microwave Test Capability
Teledyne Labtech have extensive microwave alignment and microwave testing facilities. This includes the ability to test noise figure, S-parameters and harmonics. This ensures that Teledyne Labtech can supply a fully compliant product and provide a complete turnkey microwave assembly and test solution.
-
product
Waveguide Harmonic Mixer, 26.5 to 40 GHz
11970A
The Keysight 11970A waveguide mixer is a general-purpose harmonic mixer employing a dual-diode design to achieve flat frequency response and low conversion loss. These are achieved without external dc bias or tuning stubs. Manual operation and computer-controlled hardware operation are simplified because mixer bias and tuning adjustment are not required.
-
product
Voltage Controlled Oscillators
a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.
-
product
PXI-2597, 26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module
778572-97
26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2597 is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. The internal termination of the PXI‑2597 helps prevent high-power reflections that arise from open channels on the module. You can use the PXI‑2597 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
Parallel Active Multifunction Filter
SINAF 3.0
Lifasa - International Capacitors, SA
The active filters offer the best possible solution to solve the problems related to the quality in the electrical network, both in industrial three-phase installations, as commercial or service installations. These problems are caused, not only by the harmonics, but also by the consumption of reactive power (generally of capacitive type).
-
product
Frequency Multipliers
Excellent suppression of undesired harmonics and spuriousLow multiplier lossRugged coaxial and surface mount packages
-
product
Harmonic Filters
ENTES Harmonic Filter Reactors are used in serial connection with capacitor banks in power factor correction units. By using these types of detuned reactors it is possible to increase the capacitor impedance against harmonic currents and to keep the resonance frequency under the frequencies in which main harmonic currents occur by shifting the resonance frequency.
-
product
Waveguide Harmonic Mixer (smart mixer), 50 to 75 GHz
M1971V
Keysight M1971V 50 to 75 GHz waveguide harmonic mixer is an un-preselected mixer that provides a complete solution for wideband millimeter-wave signal analysis of more than 2 GHz with X-Series signal analyzers. Embedded smart features help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
product
PXI-2799, 40 GHz, 50 Ω, Dual SPDT PXI RF Relay Module
782359-01
40 GHz, 50 Ω, Dual SPDT PXI RF Relay Module - The PXI‑2799 is a general-purpose single‑pole double‑throw (SPDT) switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2799 is also well-suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
Microwave Downconverter, 3 GHz to 26.5 or 110 GHz
E5053A
The E5053A microwave downconverter is designed to operate with the E5052A/B signal source analyzer (SSA). When configured with the E5053A microwave downconverter, the E5052A/B SSA offers exceptional phase noise sensitivity up to 26.5 GHz. Additionally, combining a pair of 11970 series harmonic mixers offers the phase noise measurement up to 110 GHz.
-
product
PXI-2798, 40 GHz, Dual-Transfer PXI Transfer Switch Module
782358-01
40 GHz, Dual-Transfer PXI Transfer Switch Module—The PXI‑2798 can route RF or microwave signals in automated test applications. Designed to operate with less than 1 dB insertion loss at up to 40 GHz, the PXI‑2798 appears almost invisible to signals at much lower frequencies as well. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2798 is also well-suited for passing high-order harmonics from RF upconverters or routing multiple sources to RF downconverters.
-
product
DT Range Broadband Power Amplifiers 10 KHZ - 1000 MHZ
DT Series
Class A solid stateBroadband (instantaneous single band): 10 kHz 1000 MHzTypical output power : 25 W CWLinear output power (1 dB compression) guaranted with harmonics <-20dBc:P1dB > 20 W and H<-20 dBc up to 450 MHz andP1dB > 10 W and H<-20 dBc from 450 MHz to 1000 MHzAir cooling: self contained fansCan operate in full mismatch conditions without damageReliable, efficient and robust19" Rack3 years standard warranty
-
product
Digital Arrester Clamp Tester
ALCL-40
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
product
Energy and Harmonics Analyzer
STAR3
STAR 3 is a high quality 96x96mm panel energy analyser provides brilliant features at a price never reached before. The new bright red LCD display, the harmonic analysis, the wide set of measured parameters including the THD available in all the models, the multi-protocol capability of the RS485 port and the high accuracy class 0.5%, the 3 years-warranty period, allow to consider the STAR 3 the new state of art of the panel analysers market
-
product
Integrated Function Tester for Inductance Ballast
UI2001B
• Measure input parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components. V range: 10.0~300.0V, A range: 0.010~2.000A, F range: 45~65Hz • Measure output parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components Lamp voltage range: 10.0~450.0V, Lamp current range: 0.010~2.000A • Accuracy: ± (0.4% reading+0.1% range+1 digit) • Can test every kind of curve, print both data & curve • Communication interface available for PC, running under Windows98/2000/XP/Vista
-
product
High Voltage Power Capacitors
Lifasa - International Capacitors, SA
Capacitors of correction power of cos φ and filtering of harmonics for AT of Lifasa, are manufactured under the base of the container / stainless steel box and porcelain terminals. There are two types, depending on the connection mode that we are going to use:*Single-phase (1 or 2 terminals) with internal fuses, for connection to the network through a double star. Recommended for networks of tension superior to 11 Kv or need of equipment of high power.*Three-phase (3 terminals) with internal fuses, for direct connection to three-phase network. Recommended for voltage networks lower than 11 Kv.
-
product
Harmonics And Flicker Measuring System
ProfLine Series
The Teseq ProfLine system is a complete and cost effective Harmonics and Flicker measurement test system which compiles to the latest IEC/EN standards, including IEC 61000-3-2 and IEC 61000-3-3. The programmable power generation capability of up to 45 kVA (90 kVA and 145 kVA sources comprise multiple 45 kVA units) provides more than ample power to cater for a wide range of Equipment Under Test (EUT).
-
product
Power Meters
Teledyne Test Tools range of digital power meters are for single-phase (1P/2W) AC power measurements with a test Bandwidth ranging from DC, 0.1 Hz to 100 kHz. The T3PM1006 model features a 4” TFT LCD screen with a five-digit measurement display. It offers 19 power measurement parameters to choose from, integration measurement function, front/rear panel input terminals, and various communication interfaces to help users to make convenient and accurate power measurement. The T3PM1100 model offers DC, 0.1 Hz ~ 100 kHz test bandwidth, 16 bits ADC, and 300 kHz sampling rate. It features a 5” TFT LCD screen with a five-digit measurement display. It also has options to display waveform (voltage/current/power), the integration measurement function, harmonic measurement and analysis of each order (meeting the IEC 61000-4-7 harmonics measurement requirements at 50/60 Hz), external sensor input terminals, and various communication interfaces to help users to make convenient and accurate power measurements.
-
product
Three Channel AC Magnetic Field Signal Conditioner
TCM-1A
Macintyre Electronic Design Associa
The TCM-1 is a three-channel portable signal conditioner specifically tailored to provide power to and process the signals from MEDA's line of AC magnetic field sensors. The unit operates from either its internal batteries or the power line. It incorporates two sets of power line rejection filters, switch selectable for 50 or 60 Hz and the corresponding first four harmonics.
-
product
Three-Phase AC Power Source 320 Vrms, 6 KVA, 550 Hz
AC6906L
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
product
Analog Earth Tester
FT3151
Earthing or grounding of electrical equipment is essential to maintain safety, protecting lives, as well as prevent damage to equipment. • Three-electrode method, Two-electrode method (Simple Measurement) • Wide measurement range for 0 to 1150 Ω, based on EN standard •Switchable measurement frequency to reduce the effects of power supply harmonics • Dramatically faster setup: Comes with improved grounding rods and cord winders. CAT II 300 V