Filter Results By:
Products
Applications
Manufacturers
Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
- Pickering Interfaces Inc.
product
Standard Voltage 50 Pin D-Type Connector Blocks and Breakouts for Pickering
The connector blocks and breakouts below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
product
Hydrogen Frequency & Time Standard
CH1-1006
The hydrogen frequency and time standard Ch1-1006 is designed to generate highly stable, high-frequency, spectrally pure sinusoidal 5, 10, 100 MHz and pulsed 1 Hz signals and for the behavior of time-frequency measurements.
-
product
Hydrogen Frequency & Time Standard
CH1-1033
The hydrogen frequency and time standard Ch1-1033 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main areas of application: – public service of time and frequency; – ground control complexes of radio navigation systems; – radio interferometry with extra long base.
-
product
Active Type Hydrogen Frequency
CH1-1003M
Hydrogen frequency and time standard Ch1-1003M is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main applications: – national time and frequency services; – ground stations for tracking and control of satellite radio navigation systems; – radio interferometry with extra long base.
-
product
Hydrogen Frequency & Time Standard
CH1-1007
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
product
Hydrogen Frequency & Time Standard
CH1-1035
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
product
Distribution Amplifiers
The Quartzlock range of distribution amplifiers are intended for use when multiple outputs from a single frequency standard/generator are required. This may be encountered in engineering labs, national standards labs, research and development, calibration labs and production. This is vital for the distribution of signals from other precision frequency standards like Hydrogen Masers, Cesium oscillators. For a technical discussion about distribution amplifiers go here or select a product range below.
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
K-50 Series Probes
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
110 GHz Frequency Extender
N5293AX03
The N5293AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX02
The N5295AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Frequency Converter
A6000-E1
The Quartzlock A6000-E1 is a 1U rack mount, frequency converter for use with frequency standards such as rubidium, cesium, or hydrogen maser standards. Sine wave outputs are provided at frequencies of 2,048 kHz
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Disciplined Frequency Standards
2960AR and 2965AR
The 2960AR has a rubidium timebase and provides two 10MHz and one 5MHz sine wave outputs. The 2965AR has a rubidium timebase and provides one 10MHz, one 5MHz and one signal generator output. The signal generator output uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50MHz via an RS232 serial interface. Both models can be disciplined by a 1pps input signal and provide a 1pps output. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Frequency Standards
Precision Test manufacturers a complete range of frequency standards. This includes rubidium and OXCO models either free running or controlled by an external reference (GPS, GLONASS, Galileo, 1pps, 5 MHz, 10 MHz, IRIG-B etc). Output frequencies typically 1 MHz, 5 MHz, 10 MHz, 10.23 MHz, 13 MHz, 100 MHz or bespoke frequency.
-
product
110 GHz Frequency Extender
N5293AX53
The N5293AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Frequency Standard Products
The ES-110 generates a stable source of 10 MHz using GPS (Global Positioning System) satellites as a reference. If frequency distribution is needed, we offer the ES-210, a Quad 1x6 1/5/10 MHz Distribution Amplifier. The ES-210 provides four independent 1x6 Frequency DAs in a single rack-mount enclosure. The ES-410 is a four output version of the ES-110. The ES-410 was introduced and won Radio Magazine's Best of Show Award at the 2016 NAB Show.
-
product
VXI Rubidium/GPS Frequency Standard
3352A Series
The Racal Instruments™ 3352A Rubidium frequency standard module and the 3352A-GPS, its GPS-disciplined companion, set a new standard for high density functionality in a single width VXI module. Using ANSI Standard M-Module building blocks, the 3352A series integrates the functions of a Rubidium oscillator and clock distribution together with an optional trigger distribution module and an optional digital I/O (DIO) module.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00