Filter Results By:
Products
Applications
Manufacturers
Reflectance
fraction of the electromagnetic energy.reflected.
-
product
Reflectance Standards
STAN Series
Ocean Optics offers specular reflectance standards for measuring shiny surfaces such as machined metals and semiconductor materials and low-reflectivity surfaces such as anti-reflective coatings and thin film coatings. The STAN-SSH varies in reflectivity from 87%-98% over the 200-2500 nm wavelength range and is available in a version (STAN-SSH-NIST) calibrated to a NIST master standard. The NIST calibration data range is 250-2500 nm.
-
product
Reflection/Transmission Test Chamber
CHTR-100
When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.
-
product
Verifier Computer Interface Report
VCIR
The Verifier Computer Interface Report (VCIR) is a Windows software package that allows for transferring inspection report from your Inspector series bar code verifier to a computer. Once transferred you can review the ISO/ANSI inspection results or view the scan reflectance profile for detailed troubleshooting. The inspection results can be saved by job for later retrieval or to append new inspection results to the existing job. As each job is saved an Excel spreadsheet (CSV file) is generated. You can customize which parameters should be saved in the spreadsheet. The spreadsheet provides a simple report that will have a line for each bar code inspected.
-
product
UV-Vis Double Beam Research Spectrophotometer
UVD-3400
UVD-3400 has an excellent performance blazed holographic grating optimized and optional reflectance attachment CT-type Monochromator and reduces stray light and widen the photometric range. Wavelength range: 190 nm – 900 nm ; Spectral bandwidth: 2nm
-
product
Hybrid Diffuse Reflectance Spectrometer
Poly602™
Solar Light has developed the fastest performing DRS instruments on the market, keeping product research, formulation and clinical testing in mind. HDRSplus™ software is designed specifically for a clinical testing laboratory environment and simplifies all HDRS calculations.
-
product
Standard-Res Spectroradiometer
FieldSpec 4 Standard-Res
Analytical Spectral Devices, Inc.
The FieldSpec 4 Standard-Res portable spectroradiometer is the right choice for a wide range of remote sensing applications, including multispectral sensor ground truthing and calibration, agricultural analysis, and snow and ice studies. In addition to being a world class spectroradiometer, the FieldSpec 4 Standard-Res is equally suited to serve as a rugged, portable spectrometer for accurate contact reflectance
-
product
Spectroscopic Reflectometry
Measure reflectance of flat or curved samples with smooth or rough surface.
-
product
Flatness Mirror
10773A
The Keysight 10773A Flatness Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror, used in the 5530 Laser Calibration System, measures flatness in applications such as surface plate calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10773A.
-
product
Gloss & Reflectance
Visual appearance can determine a person’s perception of a product. Colour and Gloss are two key parameters that are used to define a product’s overall quality. Perception is subjective, but Elcometer’s range of gloss meters, DOI meters and colour assessment equipment can quantify appearance measurement. The ability of a surface to reflect light without scattering is known as gloss. Using a gloss meter, gloss is measured by directing a constant intensity light beam at a fixed angle to the test surface and then by monitoring the amount of reflected light at the same angle. Different surfaces require different reflective angles.
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
product
Glossmeter
480
Quickly and accurately measure and record Gloss, % Reflectance & Haze measurements on a wide range of materials, including paint, plastic, ceramic or metal with the Elcometer 480 Glossmeter.
-
product
Optical Scattering Measurements & Equipment
Synopsys TIS Pro is an optical scattering instrument for efficient measurements of reflectance, transmittance and absorption. This fully automated device features an integrated sphere and a spectral detector assembled in a housing that controls stray light to ensure fast, accurate measurement results.
-
product
General Purpose Integrating Spheres
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
product
Bar Code Verifier
TP140B Report Printer
The TP140B Report printer allows for printing of inspection reports from your Inspector series bar code verifier. The printer provides a simple report that will have a line for each bar code inspected. Note: The Verifier Computer Interface Report (VCIR) is required if you need the Scan Reflectance Profile (SRP).
-
product
Optical Switch
FTBx-9150
With crosstalk of –80 dB and life expectancy of 10 million cycles, the FTBx-9150 Optical Switch is ideal for bidirectional component testing, ribbon fiber testing, multichannel monitoring, remote and multiple-component testing, signal routing and bypass switching. Housed in the LTB-8-based test systems, the FTBx-9150 provides highly accurate and repeatable fiber-to-fiber switching. It offers a choice of 1x2, 1x4, 1x8, 1x12, 1x16, 1x24, 1x32, 2x2 and 2x4 configurations. Designed for minimal reflectance, the switches integrate precision optical components into a compact modular package. Both singlemode and multimode versions are available and offer a solution for all your optical switching needs.
-
product
Spectrometer & Colorimeter
Spectroradiometer is widely used to measure the spectral, photometric and colorimetric parameters of all kinds of lighting sources which usually include relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature(CCT), color rendering index(CRI), dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, luminous flux, Illuminance, luminance, spectral transmittance and reflectance, etc. PIMACS provides different types of spectroradiometers and colorimeter to meet the requirements in laboratories or on production lines. They are applied in the measurement for general light sources, LED & OLED products, displays, etc.
-
product
Deep Ultraviolet Spectrophotometer System
VUVAS-10X
A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions.
-
product
Reflectance/Transmittance Test Set
RT-500
An Integrating Sphere is a hollow sphere which has its interior coated with a paint that is nearly perfectly diffuse or Lambertian and which has extremely high reflectance. Light energy introduced in an integrating sphere is reflected from the wall and distributed uniformly around the interior. A detector which is placed at a hole or 'Port' in the sphere wall sees an output which is completely independent of the angularproperties of the input light. The independence of the output of a sphere from the angular properties of the input and the uniform internal distribution of light make integrating spheres ideal for many uses.
-
product
Loaded Spectrophotometer
DSCD-900
DSCD-900 is a highly performance spectrophotometer with test caliber upward. The instrument adopts the geometric conditions of D/8 lighting and observation of CIE recommendations, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, maximum of colorimetric values ΔE*ab is 0.03, to provide all the necessary color formula. It could be widely used for coating, printing, textile, meet plastic, food, medicine, automobile field to meet customers’ measurement requirement.
-
product
Lens Measurement Spectrophotometers
LINZA 150
LINZA 150 spectrophotometer is designed for broadband transmittance and reflectance measurement of lenses and lens assemblies (objectives) ensuring that only perfect lenses are approved for lens assemblies, delivered to customers or meet specs provided to your lens supplier. The instrument is perfectly suited for both routine lens measurements and sophisticated improvement of lens production technology: Fast on-axis transmittance measurement of individual convex/concave lenses. Fast on-axis transmittance measurement of lens assemblies (objectives). Unattended on-axis and off-axis reflectance measurement of individual lenses providing measurement data virtually from any area on lens surface (both convex and concave). Ideal for fine-tuning of deposition technology used to produce coatings on lenses.
-
product
Solar Cell Characterisation
The PVE300 permits the determination of device spectral responsivity (from which may be determined EQE), and, having performed measurements of sample reflectance (and transmittance where required) the determination of IQE.
-
product
Diamond Testers
Napco Precision Instruments Co
Jewelry Tester is an account of full wavelength spectrum analyzer. It can appraise true or false and whether or not dyed of jewelry. its wavelength range from ultraviolet to near infrared. it can test spectral reflectance curve of hundred kinds of jewelry effectively.
-
product
Fiber Optic Measurement Systems & Sensors
MTI Instruments offers large measurement range and standoff distance fiber-optic measurement sensors and probes that provide ultra sensitive linear output response. Our modular (interchangeable) non-contact fiber optic sensors systems have dual channel that enables the user to make simultaneous measurements. Our fiber optic probes are designed to automatically compensate large changes in reflectivity making it possible to monitor dynamic reflectance of up to 100:1 making it ideal for measuring vibration of ultrasonic horns, modal analysis of disk drive suspension, displacement and timing of fuel injectors and lateral motion measurements.
-
product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
product
Chemical Absorbance Systems
UV-VIS & NIR systems for chemical absorbance measurements 190-2300nmSpectrochemistry Systems include a miniature spectrometer, light source, and sampling accessory such as cuvette holders, dip probes, & flow cellsSpectraWiz Software has built in features for ChemWiz Concentration Analyzer with multivariate chemometric optionsEpisodic capture for kinetics, time series analysis, & batch monitoringEasily convert to fluorescence or reflectance for multi applicationsGreat for Teaching Labs, Research, Process Control & much more!Also see details about our Fluorescence and Raman Systems
-
product
Integrating Sphere Coating
SP-80
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. A good internal coating is essential forintegrating spheres. It is a special water based BariumSulphate (BaSO ) white reflective paint particularly suitablefor internal coating of Integrating Spheres. It offers an almost constant reflectance in the range of 380 nm to 780 nm (visible wavelength range).
-
product
Flatness Accessory Kit
55282A
The 55282A Flatness Accessory Kit is composed of an 10759A Footspacing Kit and two 10773A Flatness Mirrors. The footspacing kit provides three precision baseplates, with 50.8 mm (2 in), 101.6 mm (4 in), and 152.4 mm (6 in) pad spacing respectively, that minimize the grid setup and data accumulation time required for plate calibration. The flatness mirrors provide 100 percent reflectance and turn the direction of an incoming laser beam 90 degrees.
-
product
Laser Flash Photolysis
This system that makes complex electronics, cumbersome software and large optical benches a thing of the past. The LFP system incorporates everything needed except the excitation laser. This is a simple, yet powerful instrument, ready to perform a wide range of time resolved kinetic and spectroscopic measurements involving transient absorption or diffuse reflectance. The LFP system, including the monochromator and digitizer is completely computer controlled, making it easy to obtain
-
product
Turning Mirror
10772A
The Keysight 10772A Turning Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror is used in the 5530 Laser Calibration System for applications such as machine tool calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10772A.
-
product
SRA01-Albedometer
Hukseflux Thermal Sensors B.V.
SRA01 albedometer is an instrument that measures the solar albedo, or solar reflectance, and net solar radiation. It is composed of two second class pyranometers with thermopile sensors, the upper one measuring global radiation, the lower one measuring reflected solar radiation. It complies with the latest ISO and WMO standards. SRA01 can be connected directly to commonly used datalogging systems.