Filter Results By:
Products
Applications
Manufacturers
Reflectors
-
product
Reflector
NetProbe 10GR
The NetProbe 10GR reflector provides loopback functionality in a low-cost, handheld device. It’s a smart loop device that swaps the source and destination addresses in MAC and IP headers as necessary to run Ethernet performance tests.
-
product
Trihedral Corner Reflectors
TCR Series
Precision radar cross section measurements demand precision calibration targets like the TCR Series trihedral corner reflectors. Manufactured to close mechanical tolerances, TRC trihedrals provide reliable and repeatable calibration standards over a wide frequency range through 100 GHz. Surface flatness and perpendicularity are maintained to 1/100 of a wavelength to insure close agreement with theoretical performance.
-
product
Sensors for Positioning
Leuze electronic GmbH + Co. KG
With moving system parts that need to automatically work together, the positioning of parts or work pieces with millimeter accuracy is of great importance. For this purpose, sensors with various operating principles are provided: laser distance measurement devices that measure against a reflector, bar code positioning systems whose red light laser determines position and speed relative to a bar code tape, sensors for optical guidance using edge detection as well as solutions for camera-based compartment fine positioning.
-
product
Plane Mirror Converter
10722A
The Keysight 10722A plane mirror converter modifies the use of the 10702A linear interferometer. With an additional 10703A reflector, the 10722A converts the 10702A into a 10706A plane mirror interferometer. With an additional 10723A high-stability adapter, the 10722A converts the 10702A into an 10706B high-stability plane mirror interferometer.
-
product
Troposcatter Antennas
Kratos Defense & Security Solutions, Inc.
Troposcatter antennas consist of a reflector structure, feed assembly, and support. Reflectors are precision-formed by aluminum spinning to maintain extremely accurate contour and high performance. Back structures are hot-dip galvanized structural steel. All aluminum parts are corrosion coated and painted.
-
product
Horizontal Profile Projector
Sinowon Innovation Metrology Manufacture Ltd.
◆ The lifting system adopts cross roller rail and precision screw drive, which makes lifting drive more comfortable and stable;◆ Coating process reflector, clearer image and great dustproof;◆ Adjustable contour and surface illumination, to meet with difference workpiece demand;◆ Imported high light and long using life LED illumination ,to ensure precision measurement demand;◆ High resolution optical system with clear image and magnification error is less than 0.08%;◆ Powerful Bi-axial fan cooling system,highly increase using life;◆ Powerful and colorful DRO DP400,realized fast and accurate 2D Measurement;◆ Built-in Mini-printer, can print and save data;◆ With standard 10X objective, optional 5X,20X,50X,100X objective,rotary table, foot switch ,clamp, etc.
-
product
Solar Simulation Systems
PET Solar Simulators consist of a Light Source with a built-in Lamp Power Supply. The Solar Simulator has an ellipsoidal reflector that surrounds the lamp and collects most of the lamp output. The radiation from the lamp is focused onto an optical integrator that helps produce a uniform diverging beam. The beam is diverted 90° by a mirror onto a collimating lens. Special filters are placed between the mirror and the collimating lens to shape the radiation spectra to match various air masses. The output is a uniform beam that closely matches the sun's radiation spectra for a given air mass. Various models offer different areas of illumination. Each model can be manufactured to simulate the sun's radiation for different air masses.
-
product
Fixed Site Radio Direction Finders
Our VHF/UHF/THF direction finders typically are installed in permanent or semi-permanent locations where the antenna has a relatively clear view of the surrounding area and RF obstructions and reflectors are minimal. Three stackable antennas mounted on top of a mast, tower, or building cover 115 – 1000 MHz. in three frequency bands. It can be remotely operated via an Ethernet or radio-modem connection. Networked with other fixed site or mobile direction finders and utilizing our TargetTrack software facilitates geolocation of the targeted RF emitter.
-
product
Transmission / Reflection Measurement
Measure spectral transmittance and reflectance of optical elements such as lens, plate glass, filter, reflector, prism and so on.The wavelength range is 350 to 1100 nm as standard and 220 to 2000 nm as an option.Reflection measurement of a general spectrophotometer can only measure several types of fixed angles, but in this device the incident angle of the sample at the time of reflectance measurement is variable at an arbitrary angle and the minimum incident angle at reflectance measurement is 15 ° ( Optical axis angle 30 °) can be set up.
-
product
Plane Mirror Reflector
10724A
The Keysight 10724A reflector is used with the Keysight 10706A, 10706B, 10715A and 10716A interferometers for single-axis measurements. It can also be used with the Keysight 10737L/R Compact Three-Axis Interferometers. Alignment hardware is included.
-
product
Photonic Doppler Velocimetry (PDV)
Photonic Doppler velocimetry (PDV) is an established technique used to measure high-velocity events up to tens of km/s. It is also known as heterodyne velocimetry and can be used as a supplementary tool or replacement for Velocity Interferometer System for Any Reflector (VISAR).
-
product
Linear Interferometer
10766A
The Keysight 10766A Linear Interferometer is used for general purpose single axis measurements and can be employed when the interferometer is the moving component, instead of the measurement reflector. It has a rugged, thermally stable stainless steel housing.
-
product
Retroreflector
10703A
The Keysight 10703A retroreflector (cube corner) is a basic measurement reflector for linear measurements. It is paired with the Keysight 10702A (or Keysight 10702A Opt. 001) linear interferometer, enabling general-purpose, single-axis measurements. If mass is critical, the Keysight 10703A is available without housing as the 10713B.
-
product
Vertical Measuring Projector
Sinowon Innovation Metrology Manufacture Ltd.
◆ The lifting system adopts cross roller rail and precision screw drive, which makes lifting drive more comfortable and stable;◆ Coating process reflector, clearer image and great dustproof;◆ Adjustable contour and surface illumination, to meet with difference workpiece demand;◆ Imported high light and long using life LED illumination ,to ensure precision measurement demand;◆ High resolution optical system with clear image and magnification error is less than 0.08%;◆ Powerful Bi-axial fan cooling system,highly increase using life;◆ Powerful and colorful DRO DP400,realized fast and accurate 2D Measurement;◆ Built-in Mini-printer, can print and save data;◆ With standard 10X objective, optional 5X,20X,50X,100X objective,rotary table, foot switch ,clamp, etc.
-
product
Enhanced UV Light Source
Model 30E
The Model 30E Enhanced UV Lightsource is highly efficient and may be utilized in a variety of applications. Light is collected by an ellipsoidal reflector and focused on an integrating/condensing lens array to produce uniform illumination at the exposure plane. This UV light source is available in various beam sizes up to 24 inches square with output spectra ranging from 220 nm to 450 nm, using the appropriate lamp (included). Output power ranges from 200 watts to 5 kilowatts. All OAI UV Lightsources are easily equipped with quick-change filter assemblies, enabling the user to customize the output spectrum with little effort. Optional remote exhaust fans are available.
-
product
Angular Optics Kit
55281A
The Keysight 55281A Angular Optics Kit adds pitch and yaw measurement capability to the 5530 Laser Calibration System. Ideal for use in precision calibration applications, it includes the 10770A Angular Interferometer and the 10771A Angular Reflector. Together the high-accuracy plane mirror interferometer and the angular reflector measure pitch and yaw motions along each axis that a machine tool or measuring machine travels. Results are displayed directly in arc-seconds or in mm/mm (in/in).
-
product
ULTRA-SONIC RECEIVER W/PARABOLIC REFLECTOR
MFJ-5008
Many times the noise is coming just outside your doorway, from the power lines. Power companies are usually very willing to help out with noise issues, but not all companies in this age of financial limitations will have the necessary equipment or trained personnel to properly locate nearby noise sources.
-
product
Datalink/Positioners/Controllers
Our fixed and mobile positioning systems featuring TECOM technology are used in range telemetry, flight termination, airborne and ground datalink, target tracking and jamming, signal intelligence, and direction finding applications. Positioning systems range from man-portable to 7 meter installations. Both positioning/controlling systems and turnkey solutions are available with reflector and feed assemblies reaching 0.5 to 325 GHz. With all positioners designed to meet environmental MIL-STD requirements, developing complete solutions for harsh conditions has become one of our core capabilities.
-
product
VHF/UHF Handheld Signal Location Antennas
Type NVF-2
The Type NVF-2 series of handheld directional antennas are used to locate interfering signals or noise in either the 420 – 470 MHz (Type NVF-2A) or the 900 MHz ISM band or cellular telephone bands (Type NVF-2B). Both models incorporate a solid reflector positioned behind a resonated half wave driven element, both elements being mounted on a fiberglass rod with an integral pistol grip. The configuration of the reflector and driven element are such that a deep null in the signal being received will occur when the antenna is pointed in the direction of the signal being radiated. A T-pad resistive attenuator is also incorporated in the antenna mounting enclosure to aid in the direction finding process on very strong signals or when excessive reflections present multiple returns.
-
product
Short Range Straightness Optics
10774A
The Keysight 10774A Short Range Straighness Optics combines a straightness interferometer and reflector to make measurements over a range of travel up to 3 m (10 ft). The optics form a highly-accurate optical straightedge that can measure the straightness of travel of machine-tool and measuring-machine coordinate motions with a resolution of 0.04 micrometer (1 uin).
-
product
1-Inch Cube Corner
10713B
The Keysight 10713B cube corner reflector can be used as the measurement reflector for linear measurements. It may be paired with either the 10702A Linear Interferometer or the 10705A Single-Beam Interferometer. Supplied without housing, the 10713B is suited to applications where mass is extremely critical.
-
product
Compact Antenna Test Range
700.00 MHZ – 110000.00 MHZ
A Compact Antenna Test Range (CATR) allows electrically large antennas to be measured at a significantly shorter distance than would be necessary in a traditional far-field test range. Compact ranges use a source antenna (feed) to radiate a spherical wave in the direction of a parabolic reflector, collimating it into a planar wave for aperture illumination of a Device under Test (DUT). It's lowest operational frequency is determined by the size of the reflector, its edge treatment and the absorbers. The two edge treatments available are serrated edge for general purpose applications, and rolled edge to achieve higher accuracy for special applications. Multiple-feed systems may be used to improve the far-field characteristics. A compact range test system also allows system level testing of a complete device architecture.
-
product
DYNAMIC TRACKING
VXTRACK
The C-Track dual-camera sensor is a complete portable 3D measurement solution that offers probing inspection and dynamic measurement capabilities. It is fitted with high-quality optics and special lighting, enabling it to measure all reflectors within its operating space. The probing stylus is very useful for aligning parts with respect to a referential (calculated using a group of reflectors), which allows movement or deformation monitoring directly on the part's referential.
-
product
Long Range Straightness Optics
10775A
The Keysight 10775A combines a straightness interferometer and reflector to provide measurements over a range of 1 to 30 meters (3 ft to 100 ft). The optics form a highly-accurate optical straightedge that can measure the straightness of travel of machine-tool and measuring-machine coordinate motions with a resolution of 0.1 micrometer (10 microinch).
-
product
Reflex Reflector Measurement Systems
Photometric Solutions International Pty Ltd
The measurement setup involves using a projector to illuminate the test item, and then measuring the luminous intensity of the light reflected from the test item. The ratio of the luminous intensity emitted by the reflector (in candelas) to the illuminance on the reflector (in lux) is the coefficient of luminous intensity or CIL (cd/lx).
-
product
Solar Simulation
Sciencetech solar simulators produce high intensity, uniform illumination on a target area. Typically, high power solar simulators use an ellipsoidal reflector to capture light from an arc lamp source inside the reflector, an arrangement that results in a light pattern with a bright outer region and a dark center. This non-uniformity is un- acceptable in many solar simulator applications and as a result, forces many of our solar simulator competitors to use designs involving diffusers to reduce the non-uniformity. This results in a reduction of intensity and a dis- tortion of the spectrum on the target area.
-
product
Linear Interferometer
10702A
The 10702A includes one 10703A Retroreflector as a reference reflector. A second 10703A is needed to complete the linear measurement optic set. The interferometer cannot be used to bend the beam. If the interferometer is the moving component, the 10702A Option 001 must be ordered. More about the 10703A Retroreflector
-
product
Radiometers
UV Intensity Meters & Visible Intensity Meter for Light Curing Systems. Dymax UV and visible radiometers are simple to operate and allow operators to monitor and document a UV/Visible light curing process. A low UV/Visible intensity measurement signals an operator to replace the bulb, reflector, or lightguide. Radiometers can also be used to confirm that operators are properly shielded from UV/Visible exposure. Degradation of curing bulbs, lightguides, and reflectors can decrease intensity, resulting in incomplete cures.
-
product
Accessories
From electrical connectors through reflectors, and mechanical mounting systems, SICK offers a comprehensive range of accessories to safeguard the availability of application solutions. Perfectly matched to the corresponding sensors, these accessories provide the basis for cost-effective integration into systems and are available with short lead times.
-
product
Angular Reflector
10771A
The Keysight 10771A Angular Reflector, used in the Keysight 5530Laser Calibration System, is ideal for precision calibration applications. Paired with the 10770A Angular Interferometer, it is used to measure pitch and yaw motions along each axis that a machine tool or measuring machine travels. The system can help quickly locate and evaluate unwanted angular motion.