Filter Results By:
Products
Applications
Manufacturers
Tan Delta
test's dielectric loss to determine quality of insulator.
See Also: Tan Delta Bridges, Dissipation Factor, Dielectric Test, Oil
- Virginia Panel Corporation
product
Coax, Patchcord, ITA, 36", Mini Coax, RG316 Tan, Single Ended
7-331116000-036
Coax, Patchcord, ITA, 36", Mini Coax, RG316 Tan, Single Ended.
-
product
Test Sets For Diagnostic Testing
Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.
-
product
Capacitance And Tan Delta Test
Bushing Tap Adapter Kit
Bushing Tap Adapter Kit is designed to perform Capacitance and Tan Delta tests on power transformer bushings The kit can b e used with the following ISA Test Set STS 5000 TD 5000 STS 4000 TD 5000 TDX 5000.
-
product
Oil Tan Delta Tester
Weshine Electric Manufacturing Co., Ltd
The Oil Tan Delta Tester (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. WESHINE has developed features of the OTD to ensure that productivity levels within laboratories are maximised.
-
product
Oil Resistivity & Tan Delta Test Set-Up
This testing set is an automated instrument, widely used for measuring electrical characteristics of insulating liquids, transformer oil and other insulating material samples.
-
product
Oil Tan Delta Tester
OTD
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. The microprocessor controlled inductive heater means that there is uniformity of temperature throughout the cell, in compliance with IEC 60247, and for cooling a fan effectively speeds up the cell cooling time. The instrument has a temperature measuring range of 10 to 110 C, with an accuracy of 1 C. It can be set to preheat before testing takes place. The automated oil drain facility negates the need to move the oil vessel. User safety is paramount and with this in mind, Megger have designed independent and dual redundant high voltage cut-off circuitry. If for any reason the user needs to abort the test, this can be done so by pressing any key, immediately terminating the test and removing the high voltage. The design of the cell components maximise oil fill rate but minimise turbulence in oil flow and eliminate trapping of air. With only 32 cell components, it is easy to assemble and disassemble.
-
product
Tan Delta And Capacitance Test Set
TDX 5000
TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines.
-
product
Transformer Oil Tester
GTD-61A
1. The GTD-61A Automatic Oil Tan Delta(OTD) & Oil dielectric loss tester is highly automated, allowing for the measurement of temperature rise, dielectric loss, and resistance in one go.
-
product
Automatic Capacitance and Tan Delta Bridge
*Automatic Microprocessor controlled Guarded Bridge Circuit.*Suitable for testing at voltages up to 500kV.*Can be used to measure both Grounded and Un-Grounded Specimens.*Automatic guard circuit for three-terminal measurement.*Interface measurement and automatic interference suppression circuitry.*Optional range Extension Transformer for large capacitance values.*Test data storage facility.*RS-232 computer interface and USB printer interface.*Window Interface Software for data transfer.
-
product
Capacitance & Tan Delta Testers / Tan Delta Tester
CDF 6000
UDEYRAJ ELECTRICALS PRIVATE LIMITED
CDF-6000 is fully automatic: It automatically ramps up to set test voltage, makes measurement, ramps down test voltage to zero and prints out test results.
-
product
VLF Diagnostics System
PHG 70 TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
product
VLF Testing and Diagnostics Unit
Viola TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences
-
product
VLF/DC Hipots
HVA28TD
The smallest VLF /DC unit on the market now includes an integrated Tan Delta measurement system to perform advanced electrical insulation diagnostics. For example, this can be extremely useful when performing advanced diagnostics on cable systems as it provides valuable information as to the condition of the cable insulation and shield.
-
product
Automatic Oil Tan Delta & Resistivity Kit
MOTR
The Motwane Manufacturing Company
Motwane's MOTR is multifunctional automatic test kit designed for accurate measurement of the Dielectric Constant, TanDelta, Resistivity & capacitance of transformer oil & other electrical insulating liquids. It has preprogrammed test sequences as per various International standards along with customized test sequences as per user requirements. Internal memory for 250 tests provided with PC interface & report generation facility. Inbuilt thermal printer for onsite results. Test cell is designed as per IEC247 with calibrator for onsite calibration of kit.
-
product
Tan Delta Test Set
TD 5000
The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range.
-
product
Compensating Reactor
The compensating reactors are accessories for the CTS-12KSA/ACTS-12K Capacitance & Tan Delta Test Set. The use of one or more compensating reactors increases the capacitance that the internal power supply can excite to conduct measurements. As the measuring range of the CTS-12KSA / ACTS 12K exceeds the kVA rating of the internal power supply, one way of using the test set over its entire measuring range is to form a resonant circuit with the test sample. The use of one or more compensating reactors forms partial resonating circuit with the test specimen, thereby reducing the power supply requirement.
-
product
Standard Capacitors
Ultra High Voltage standard Capacitors used for very high accuracy measurement of capacitance and dielectric dissipation factor (Tan Delta) as well as voltage measurement in capacitive dividers.
-
product
Oil Tan Delta Test Set
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.
-
product
Tan Delta Tester
HTJS-V / 270
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement high-precision instrument of dielectric loss tangent value and capacitance of high-voltage power equipment of power plant, substation and other scene automatic measurement.
-
product
Fully Programmable Digital Design with Wireless Remote Control
VLF E Series
The VLF E Series uses a state-of-the-art, switching power supply design with wireless computer controls. Equipped with HVI’s E-Link software, the E Series stands among the most advanced cable testing systems available. Our customers praise its flexible data capture and reporting capabilities, full remote operation via XBee wireless technology, and seamless tan delta testing with HVI’s TD units.
-
product
VLF Testing and Diagnostics Unit
Frida TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
product
Calibrator Module
CAP CAL
The purpose of CAP-CAL is to check the correctness of Tan Delta and Capacitance of TD 5000 and TDX 5000. The calibrator includes an extremely high accuracy high voltage capacitor, which comes with a certificate issued by ISA - Altanova Group lab.
-
product
Tan Delta Measurement
TD Series
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
product
High Voltage Capacitance & Tan Delta Test Set
*Aesthetically designed Single Unit consisting of Measuring Bridge, Power Supply with in-built Standard Capacitor. Ideal for field /portable applications.*Highly compact & Portable – Approx 66Kgs only.*Advanced Protection Circuitry –specially suitable for 400kV s/s applications.*Successfully passed all required EMI/EMC Tests at SAMEER Chennai IEC 61000-4-2;IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-11;*Improved Plug-in type of “Power In” and “Gnd” connectors.*Preo 2 Stage RF Power line Filters incorporated for 230V Power Input and Bridge Power Input for improved EMI Power line Protection*Improved 2 sets of LV measuring cables.*Improved HV cable outer covering hosepipe for rugged field use.
-
product
Capacitance & Tan-Delta Test System
TD-1
By measuring the electrical properties such as capacitance and Tan-Delta regularly on periodical basis, it is possible to ensure the operational unexpected breakdown. Dissipation factor (Tan Delta) is one of the most powerful off-line nondestructive diagnostic tool to monitor the condition of solid insulation of various high voltage equipment.
-
product
12 Kv Fully Automatic Capacitance Tan Delta Tester With Printer
NMC offer Fully Automatic Capacitance Tan Delta Test Set with Printer and Computer Interface, Range : 0-12kV, Model : CTD-12.
-
product
Tan Delta Test System
Diagnostic test that indicates the degree of cable insulation degradation. Rather than using only a VLF instrument to perform a go/no-go proof test, the Tan Delta, used in conjunction with a VLF hipot, permits the user to grade the deterioration level of many cables in order to prioritize replacement, rejuvenation, or to determine what additional tests may be useful.
-
product
Cable Diagnostic Tools
For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.
-
product
Conventional Power Supply Design with Simple Analog Controls
VLF Series
VLF hipots perform voltage withstand tests and provide the voltage source for diagnostic cable testing. There is no better method for verifying the AC integrity of a cable than applying VLF AC voltage. Tan delta and partial discharge measurement accessories are frequently purchased along with VLF equipment to extend their capabilities.