Filter Results By:
Products
Applications
Manufacturers
- CAMI Research Inc.
product
Connector Board for Cable and Harness Tester
CB49
Populated with solder pads to accept a suite of TE-Connectivity Micro-MaTch connectors, this board addresses markets plagued by vibration and fretting corrosion, and requiring "miniaturized connectivity". Rated to 500Vdc/350Vac, the CB49 may be used on all CableEye models. The CB49, sold without connectors, contains nine sets of 20 solder pads accommodating numerous configurations of Micro-MaTch connectors.
-
product
Electricity Meters Tester
TE30 Lite
Calmet Smart Calibration Devices
Electricity meters tester class 0.02%. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
product
Transformer Oil Dielectric Breakdown Voltage Tester
MG-II
Chongqing Kailian Yongrun Industrial Co.,Ltd.
The dielectric breakdown voltage test (BDV test) is an important test to determine the breakdown voltage of insulating oils. After a certain period, transformer oil will be degraded, and there are moisture, gas and impurity in oil. Then, the quality of transformer oil is affected. So it is necessary to test the transformer oil. BDV test is one of the most common tests to insulating oils.
-
product
Transformer DC Winding Resistance Tester
HTZZ-40A / 245
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement transformer around the group and large power inductor dc resistance ideal equipment.
-
product
High Quality Transformer Oil Dielectric Strength Tester
AS-023A
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
product
CT Burden Tester
585
The 585 Burden Tester is a hand held unit rated for use up to 20A. The design features a digital LED meter for displaying the current transformer (CT) secondary current. The burden is applied for a specific length of time controlled by circuitry inside the unit to help prevent the burnout of the burden elements.
-
product
Transformer ON-Load Tap-Changer Tester
WAYZ-2011
Wuhan Sangao Electrical Test Installations Limit Co.
This Transformer on-Load Tap-Changer Tester is acc to Chinese Electric Power Industry Standard, It also can meet the requirement of electrical equipment handover and prevention test standard.To achieve the accurate measurement of on load tap changer's transition time, transition resistance,three-phase synchro nization parameterssyn.It is the best test equipment of on-Load Tap-Changer.
-
product
AC High Voltage Break Down Tester
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
product
Current Transformer Tester
CT-T1
The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.
-
product
Surge Tester (Impulse Winding Tester)
SS6815 / SS6815F
Surge testers (impulse winding tester) is used for testing and check the insulation grade of turns between turns, insulation grade of layers between layers, insulation grade of windings between turns. It is used widely for transformer, current sensor, voltage sensor, relay, contactor, inductor, motor, generator, valve coil, voice coil, etc.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
Oxidation Stability Testers
Automatic lubricating oils oxidation stability tester, transformer oil oxidation stability tester, distillate fuel oil oxidation stability tester, gasoline oxidation stability tester (induction period method)
-
product
Primary Current Injection Testers
Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.
-
product
Gas-Filled Hv Testing Transformer
GTU-300KVA/600KV
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time. Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.
-
product
Current Transformer Testers
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
product
Bobbin Winding Coil Tester
SS108A series
Bobbin winding coil testers are used to test various coil of turns. Such as: generator winding turns, transformer winding turns, motor winding turns, inductor winding turns, contactor winding turns, relay winding turns, sparking winding turns, ignition winding turns, speaker voice coil, etc.
-
product
Contact Resistance Tester
JYL-200B/100B
Product description: JYL-200B/100B contact resistance tester can measure contact resistance of high voltage switches and circuit breakeres, also can test primar side resistance of transformer and grounding wire in groups
-
product
Three-circuit Transformer DC Resistance Tester
HTZZ-S10A / 218
Wuhan Huatian Electric Power Automation Co., Ltd.
Designed to meet the dc resistance test of three-phase winding in large capacity transformer.
-
product
Transformer Turn Ratio Tester
KVBB-II
KV Hipot Power Test Equipment Co.,Ltd
KVBB-II Transformer turn ratio tester is used to check turn ratio of transformer, tap switch situation, whether transformer interturn is short circuit and transformer can run in parallel or not.
-
product
Current Transformer Tester
HTCT-300
Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements.
-
product
Fully Automatic Transformer Winding Resistance Tester
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
product
Transformer Oil BDV Tester (Single Cup)
HTJY-80B / 288
Wuhan Huatian Electric Power Automation Co., Ltd.
The tester is designed to test the power strength of all kinds of insulating oil.
-
product
DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER
TURNS-LCRTZ
Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.
-
product
Tan Delta and Capacitance Tester
TDC3100L
Tan Delta and Capacitance Tester TDC3100L is fully automatic 12 kV insulation power factor/dissipation factor (tan∂) test set designed for evaluating the nature and quality of electrical insulation materials and high voltage systems such as transformers, bushings, circuit breakers, cables and windings of rotating machines etc..
-
product
GDGS Transformer Power Factor And Tan Delta Tester
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
GDGS Transformer Power Factor and Tan Delta Tester
-
product
Distribution Transformer Tester
ADOC-3
The ADOC-3 is an equipment that has been designed to test distribution network transformers from 5 kVA to 3MVA.
-
product
Winding Resistance Tester with Demagnetisation Circuit
WRT-10D
The WRT-10D is a high performance winding resistance tester designed for power transformer and large motor applications. It is equipped with a bright LCD display, a rugged high quality cable set, a built-in printer, a full QWERTY keypad and a demagnetisation circuit.
-
product
Transformer Tester
MOTOMEA Distribution Transformer Test Systems: Routine Testing for Production (EOL) and Quality Assurance (QA). Type Testing at Laboratory (R&D)
-
product
Transformer Turns Ratio Tester (TTR)
HTBC-IV / 251
Wuhan Huatian Electric Power Automation Co., Ltd.
Suitable for transformer testing of three-phase transformer, z-winding transformer, rectifying transformer and railway electrical system.
-
product
Automatic Insulation Oil Tester
KVIO-80
KV Hipot Power Test Equipment Co.,Ltd
Automatic Insulation Oil Breakdown Tester Is Used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool etc.
-
product
Transformer & Capacitor Testers
*Quick and easy check for opens or shorts on transformers before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers*Tests the primary and secondary sides of de‑energized transformers without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer*Automatic self-test feature*Magnet holds the tester in place while testing