Manta Test Systems
Electrical utilities world-wide use our products to ensure the proper design, installation, and operation of protection systems critical to the reliability of the power system infrastructure.
- 1-800-233-8031
1-905-828-6469 - 1 (905) 828-6850
- sales@mantatest.com
- 4060B Sladeview Cres. Unit 1
Mississauga, Ontario L5L 5Y5
Canada
-
product
10 A True DC Micro-Ohmmeter
AUTO-OHM 10
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field. The Auto-Ohm 10 features a built-in charger that can charge the batteries when the unit is not in use.
-
product
Digital Circuit Breaker Analyzer
CT-7000 S3
The CT-7000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-7000 S3 is available with 3 (part number 9021-UC) or 6 contact timing channels (part number 9100-UC). The CT-7000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Both contact and motion analysis can be performed on all circuit breaker operations (OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, and OPEN CLOSE-OPEN). The CT-7000 S3’s timing window is selectable between 1 second, 10 seconds, and 20 seconds.
-
product
Protective Relay Test System
MTS-5100
The MTS-5100 is the only all-in-one relay test set with a direct front panel interface for all functions, without exception!
-
product
Protective Relay Testing
Choose from Doble’s F6300e and F6350e External Amplifiers for your specific protection testing needs and requirements. These amplifiers are useful in high power protection testing applications when you need additional current and/or voltage sources, for critical high burden relay testing, as well as system modeling.
-
product
Power System Simulator
F6150e
This power system simulator performs the simplest through the most complex tests. Meeting all your protective relay testing needs, the F6150e is available in different configurations.
-
product
75 K Vdc Vacuum Bottle Tester
VBT-75 S2
The VBT-75 S2 is Vanguard’s second generation microprocessor-based, portable, 75kV dc vacuum bottle tester. This lightweight, portable tester is designed for testing circuitbreaker vacuum bottles in the field and at the shop.
-
product
Leakage Current Monitor
LCM500
The Doble LCM500 Leakage Current Monitor can measure condition while a surge arrester is still in service, measuring the quality of the metal oxide blocks and helping manage the risk of failure.
-
product
Digital Circuit Breaker Analyzer
CT-8000 S3
The CT-8000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available with 3 (part number 9103-UC) or 6 contact timing channels (part number 9104-UC). The CT-8000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Also, an outstanding feature of the CT-8000 S3 is the ability to perform dynamic resistance tests on circuit breaker contacts.
-
product
Digital Circuit Breaker Analyzer
CT-3500 S2
The CT-3500 S2 is Vanguard’s second generation, stand-alone, digital, microprocessor-controlled, circuit-breaker timer. It measures the elapsed time from the instant a breaker coil is energized to the instant of opening or closing of a circuit-breaker’s dry contacts. In addition to timing a breaker’s contact response time, the CT-3500 S2 can also time relays or other switching functions that use an initiating trigger voltage (24-300 Volts DC or AC). The timer-triggering voltage starts three independent electronic timers. Each timer is individually stopped by its respective dry-contact closing or opening. The CT-3500 can fully analyze the timing of all circuit breaker operations (Open, Close, Open – Close, and Close – Open). Timing results are displayed in milli-seconds and cycles on the unit’s back-lit LCD screen and can be printed on the built-in 2.5-inch wide thermal printer.
-
product
Universal PD & EMI analyzer
Spark P3
Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.
-
product
Variable AC/DC Power Supply
UPS S2
The Vanguard Universal Power Supply Series 2 (UPS-S2) is designed and produced to meet a utility company’s substation needs for an independent AC/DC power source. Both the AC and DC Voltage sources are capable of supplying 10 amperes continuously.
-
product
Programmable DC Power Supply
CBCT
The CBCT is a variable voltage DC power supply designed specifically to test substation circuit-breaker Open and Close coils. The CBCT uses the substation’s DC power supply to electronically generate a programmable output voltage from 5% to 95% of the source voltage. The CBCT can maintain up to an 80A test current while maintaining 2% or better voltage regulation during the circuit breaker coil operation.
-
product
250 A Molded Case Circuit Breaker Tester
MCCB-250
The Vanguard MCCB-250 is a programmable, high-current source designed specifically for testing molded-case circuit breakers, thermal magnetic and solid-state overload motor-protection relays.
-
product
Protection Testing Accessories
Protection testing programs can vary from team to team and company to company.
-
product
Seven-Module Test Set
F8300
Use the F8300 for testing three-phase conventional schemes and digital protection systems. This seven-module F8000-series instrument is available in five standard configurations of HVA Current, HVA Voltage, and Low-Density Logic I/O modules.