Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States
-
product
Chemiluminescence NH3 Analyzer
Model T201
Teledyne Advanced Pollution Instrumentation
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter (see "Features" tab for external converter photo) to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.
-
product
Catalytic Ozone Destructs
CAT-O3 Series
Teledyne Advanced Pollution Instrumentation
The CAT-O3 series of ozone destructs safely decompose high concentrations of ozone gas to sub-ppm levels that are below recommended ozone safety limits. The catalytic method of decomposition uses a metal oxide catalyst to passively convert the ozone to oxygen.
-
product
Trace-level, Photolytic, True NO2/NO/NOx Analyzer
Model T200UP
Teledyne Advanced Pollution Instrumentation
The Model T200UP provides trace level measurements of NO and NO2 using our Model T200U NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.
-
product
Nitrogen Compound Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API produces a wide range of instruments for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring
-
product
Trace-Level UV Fluorescence SO2 Analyzer
Model T100U
Teledyne Advanced Pollution Instrumentation
The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.
-
product
Mid-Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200M
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
product
PM Mass Monitor
Model T640
Teledyne Advanced Pollution Instrumentation
The Model T640 PM Mass Monitor is the next breakthrough in ambient particulate monitors. The T640 delivers 1-min or better time resolution with exceptional sensitivity and precision. The instrument is very low maintenance and requires no sample media for minimal cost of operation.
-
product
CAPS True NO2-NOX-NO Analyzer
Model N500
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
product
Chemiluminescence NO/NO2/NOX Analyzer
Model T200
Teledyne Advanced Pollution Instrumentation
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.
-
product
UV Fluorescence TRS Analyzer
Model T102
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
product
Gas Calibrators and Zero Air Generators
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
product
Gas Filter Correlation CO2 Analyzer
Model N360
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
Dissolved Ozone Analyzer
Model 470
Teledyne Advanced Pollution Instrumentation
The Model 470 is a state-of-the-art Dissolved Ozone Sensor designed for semiconductor Wet Bench tools and many other industrial processes. It provides continuous measurement of dissolved ozone in deionized water or sulfuric baths with concentrations up to 150 mg/L. The Model 470 is “clean-ready” for high purity semiconductor processes, and is designed to be simply spliced in-line in the recirculation loop of any wet bench tool with flow rates up to 150 SLPM.
-
product
Chemiluminescence NOX-NO2-NO Analyzer
Model N200
Teledyne Advanced Pollution Instrumentation
The Model N200 uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases.
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.