Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States of America
-
Product
Trace-Level Chemiluminescence NO/NO2/NOx Analyzer
Model T200U
-
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
-
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Mid-Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200M
-
Teledyne Advanced Pollution Instrumentation
The Model N200M uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
Product
Chemiluminescence 03 Analyzer
Model T265
-
Teledyne Advanced Pollution Instrumentation
The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.
-
Product
Nitrogen Compound Instruments
-
Teledyne Advanced Pollution Instrumentation
Teledyne API produces a wide range of instruments for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring
-
Product
Process Ozone Monitor
Model 465M
-
Teledyne Advanced Pollution Instrumentation
The Model 465M is a microprocessor based medium range ozone monitor for measuring process ozone concentrations in water treatment, food processing, and research applications. The design has been specifically optimized for applications requiring the measurement of ozone at near-ambient pressure such as water treatment contactor off-gas measurement. The Model 465M has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465M is available in a NEMA 4X wall mount enclosure.
-
Product
CAPS True NO2-NOX-NO Analyzer
Model N500
-
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
Product
Portable Gas Calibrator
Model T750
-
Teledyne Advanced Pollution Instrumentation
The Model T750 is a portable, microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750 is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.The Model T750 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPT. A number of calibration sequences may be programmed into the non-volatile memory of the Model T750, covering time periods up to a year.
-
Product
PM Mass Monitor
Model T640
-
Teledyne Advanced Pollution Instrumentation
The Model T640 PM Mass Monitor is the next breakthrough in ambient particulate monitors. The T640 delivers 1-min or better time resolution with exceptional sensitivity and precision. The instrument is very low maintenance and requires no sample media for minimal cost of operation.
-
Product
UV Fluorescence H2S, SO2 Analyzer
Model T101
-
Teledyne Advanced Pollution Instrumentation
The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.
-
Product
UV Absorption O3 Analyzer
Model T400
-
Teledyne Advanced Pollution Instrumentation
The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.
-
Product
Mid-Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200M
-
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
Product
Hydrocarbon Instruments
-
Teledyne Advanced Pollution Instrumentation
Teledyne API has developed a hydrocarbon instrument using patented gas chromatograph (GC) technology, in combination with well-characterized and familiar Flame Ionization Detection (FID). This instrument uses a new modular hardware and electronics architecture which is the basis for Teledyne API's new N Series platform. The instrument platform is thoughtfully designed for reliability, ease of operation and maintenance, low power consumption, and advanced communications and diagnostic capabilities.