Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@Lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road, Jiading District
Shanghai, 201802
China
-
Product
DIP LED Aging Tester
LS6100
-
Designed to measure the aging-life and color comparisons of 260pcs DIP LED. • 260 separate constant current supply • Aging functions: constant current, impact pulse, on-off mode • Range of forward voltage(VF): 5.0V • Range of forward current(IF): 1) constant current: 0-100.0mA 2) Impact pulse: 0-200.0mA • Range of impact pulse frequency: 10-9999Hz; Duty ratio: 1%-99% • Range of on-off circle: 0-9999H59M59S • Range of on-off times: 0-9999times • Range of aging time: 0-9999H59M59S
-
Product
Quick-Scan Spectrophotometer Colorimeter
LMS-5000
-
LMS-5000 Quick-Scan Spectrophotometer Colorimeter is a very widely applied single monochromators spectrophotometer with high accuracy. A typical measuring time during the spectral range from 380~800nm is less than 10 seconds. LMS-5000 used with right size integrating sphere and standard light source can be applied to do spectral measurement of LEDs, LED modules, CFL, Fluorescent Lamp, CCFL, HID lamps and other luminaries.
-
Product
Thermally Protected Ballast Heating Test Chamber
TPB-UL935
-
Working room dimension: 610×610×610mm• Temperature range: RT+10℃~+100℃• Materials of inner and outside chamber: Senior stainless steel• Insulation Material: Ultra-fine glass wool insulation material• Heater: Dedicated strip heater (heating surface area of 300 × 40 mm), each group three hundred watts, a total of four groups, with the power supply in parallel.• Special wooden test sample holder• Third gear temperature measurement points (at any time monitoring and conversion)
-
Product
Spring Impact Hammer IK Level Tester
IK01-06
-
The most of luminaires manufactory were request to do IK level test (Impact Protection), LISUN can supply the IK test instrument. IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
Product
Rotation Luminaire Goniophotometer
LSG-1800
-
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Online OK Tester for Electronic Ballast and CFL
WT-1
-
• Test 6 pieces at one time, suitable for mass testing in assembly line. • Measure parameter: Vrms, lrms, W, PF. • Freely set upper and lower limit for lrms, W, PF, alarm when value out of limits. • Freely set test duration in range: 0-99.9s, tested data automatically locked. • Test range: 1) Vrms: 10.0-300.0V 2) lrms: 5-999mA 3) W: 0.1-300.0W 4) PF: 0.0001-1.000 • Accuracy: 0.5% • Digital display on 6 windows is easy to read • Print port and communication port available (optional)
-
Product
Mask Bacterial Filtration Efficiency (BFE) Tester
WKS-1010
-
WKS-1010 Mask Bacterial Filtration Efficiency (BFE) Tester is used to test the percentage of the mask material to filter out the suspended particles containing bacteria under the specified flow rate. It is suitable for the performance test of the bacterial filtration efficiency of medical surgical masks by metrological inspection departments, scientific research institutes, medical mask manufacturers and other related departments.
-
Product
Digital Power Meter (AC & DC Model)
LS2012
-
• Measure Vrms, lrms, W, PF/Hz; • Measure AC, DC, AC+DC; • Automatic selecting, out of limit alarming, advance the work efficiency; • Voltage range: AC: 5-600V, DC: 1-600V. Current range: AC&DC: 0.005-20A with high measure accuracy. Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit).
-
Product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
-
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
-
Product
Pull Out Device
BCL-1
-
This Pull out device BCL-1 is designed and manufactured according to relevant standard requirements of IEC884-1/ GB2099.1-2008 and other electrical accessories standards, Mainly used to test the needed maximum force when the plug pull out from socket and the minimum force when single stage plug pull out from socket, and to inspect whether the socket can withstand the lateral stress imposed by electric plug into the socket. This device is applied to plugs and sockets which rated voltage no more than 250V and rated current no more than 16A.Specifications: • Weights: 36N*1, 5.4N*1, 5N*2, 4N*1, 2.6N*1; • Standard testing plug: each one for Dipolar 10A, tripolar 10A and 16A • Standard test bolt: Each one for 1.5N and 2N • 1 set of clamping device • 1 set of Weights tray • Lateral stress weights 5N*1 • 1 set of lateral stress bar
-
Product
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B
-
Cabinet Shell2mm galvanized cold-rolled steel sheetCabinet Door0.9*1.7m(L*W)0.6*0.6mCabinet Window0.3*0.3*0.025m(L*W*T) with 4mm holeN/APower Supply Filter30A/220V30A/220VInternet Line FilterRJ-45N/ACabinet Inside DecorationPVC ceiling, PVC plastic steel wall, 10mm wooden + 2mm galvanized steel sheet floorCabinet Inside Size2*1.2*1.8m0.8*0.8*0.8mAfter Packing Size2.2*2.3*2.3m1*1.1*1.2mAfter Packing Weight800kg200kgWorking With EMI-9KA/EMI-9KBEMI-9KA/EMI-9KB, PC, Testing load, and operator insideTesting load is inside to connect with EMI-9KA/EMI-9KB via BNC
-
Product
Insulation Resistance Tester
WB2681A
-
• Insulation test voltages: DC250V、DC500V、DC1000V • Range of open-circuit voltage: ±10% rated voltage • Testing time: 3~99 seconds or controlled manually
-
Product
Low-Temperature Impact Device
DWC-1
-
This low-temperature impact device is compliance with standard requirement of IEC60245, IEC60227, IEC60540, GB5013-2008, GB5023-2008 and GBT2951-2008. It’s used to test all kinds of PVC sheathed cable, wire, soft wire and no sheath of parallel soft PVC insulated impact resistance at low temperature. Specification: • Working temperature: -15℃±1℃ • Impact height: 10~200mm adjustable • Length of specimen: 5D~150D • Material: 304 stainless steel • Completion time once: 3~5s • Completion number of units for once: ≥2pcs • Weight: 100/200/300/400/500/600/750/1000/1250/1500g • Low temperature box to match additionally
-
Product
Impulse Magnetic Field Immunity Tester
IMF61000-9
-
IMF61000-9 impulse magnetic field immunity tester is high performance test instrument which special designed for to do impulse magnetic field immunity test and fully meet IEC61000-4-9, EN61000-4-9 and GB/T17626.9 standards, also it come with high intelligent, high stable performance and easy operation characteristics.
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.















