Contaminant
-
Product
Filters, Collectors, Separators, Purifiers
-
Parker's filters, separators and purifiers come in a variety of options and media and are used to filter out air or fluid contaminants in an array of industrial and commercial applications.
-
Product
EDX-FTIR Contaminant Finder/Material Inspector
EDXIR-Analysis Contaminant Finder/Material Inspector
-
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues identification results and the degree of matching. it can also be used to perform EDX or FTIR data analysis on its own. The library used for data analysis (containing 485 data as standard) is original to Shimadzu, and was created through cooperation with water supply agencies and food manufacturers. Additional data can be registered to the library, as can image files and document files in PDF format. It is also effective for the linked storage of various types of data as electronic files.
-
Product
EDXIR-Analysis Contaminant Finder/Material Inspector
-
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues identification results and the degree of matching. it can also be used to perform EDX or FTIR data analysis on its own. The library used for data analysis (containing 485 data as standard) is original to Shimadzu, and was created through cooperation with water supply agencies and food manufacturers. Additional data can be registered to the library, as can image files and document files in PDF format. It is also effective for the linked storage of various types of data as electronic files.
-
Product
Digital Inspector
DI-2000
-
Many modern network issues can be traced to contaminated or damaged fiber optic connector endfaces. Lightel’s DI inspection probe series provides ergonomic, easy-to-use, and versatile inspection of the endfaces for fiber optic male and female, single and multi-channel connectors.
-
Product
Molecular Contamination
-
Ion mobility spectrometers detect and alert users to small concentrations and changes in airborne levels of chlorides, acids, amines, and ammonia-containing species.
-
Product
Elcometer Bresle Patches
135B
-
Elcometer 135B Original Bresle Patches are used to determine surface chloride contamination and are self-adhesive rubber film patches with a sealed compartment for sampling soluble impurities from steel surfaces with a suitable solvent.
-
Product
2100Vdc Screw Terminal Connector Board | Cable & Harness Tester
CB29H
-
CAMI Research Inc. (Acton, MA) announces another new board for its CableEye cable and harness testing systems. Populated with four 16-pole screw terminal blocks, the board addresses high voltage (HiPot) testing to 2100Vdc/1200Vac. Of particular interest to the harness testing market, the CB29H is also available as a transition board variant (CB29AH). The CB29H and CB29AH boards are high voltage versions of the CB29 with the high voltage traces running on inner layers to afford additional safety, and protection from contamination.
-
Product
Conformal Coating Inspection (CI AOI)
-
They cover the components, the area around the components and identify most coating issues including cracks, bubbles, insufficient / excess coating, loss of adhesion and other common contaminations. Full coverage inspection for conformal coating.
-
Product
Thermal Testing
-
At E-Labs, Inc., we support thermal cycling and thermal bakeout vacuum testing requirements. During thermal cycling, the unit experiences repeated heating and cooling as it would when exposed to the harsh environment of space. During thermal bakeout, flight equipment is subjected to an outgassing reduction process so as to decrease the chance of molecular contamination of the spacecraft instrumentation.
-
Product
Portable Kinematic Viscometer
MiniVisc 3000
-
The MiniVisc 3000 series (formerly the SpectroVisc Q3000 Series) viscometers are the first truly portable, solvent-free, temperature-controlled kinematic viscometers, providing high-accuracy measurements for easy detection of viscosity variations caused by contamination, mix-up and oil degradation. The devices were designed to determine kinematic viscosity at 40C in the field for applications where immediate results are essential for determining the health of critical equipment.
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
Gross Alpha/Beta Measurement Systems
-
Gross alpha/beta measurement is one of the simplest radioanalytical procedures which are applied widely as a screening technique in the field of radioecology, environmental monitoring and industrial applications. This procedure has been developed to determine whether radionuclide specific analysis is required to further characterize the water. Regular measurements of gross alpha and gross beta activity in water may be invaluable for early detection of radioactive contamination and indicate the need for supplemental data on concentrations of more hazardous radionuclides.
-
Product
Fluid Contamination Test
-
Fluid contamination testing determines the abilities of materials to withstand the contaminating fluids, to which they are exposed in service.
-
Product
Stealth Pharmaceutical Metal Detector
-
Stealth Pharmaceutical metal detectors are custom manufactured to suit Pharmaceutical and/or Nutraceutical applications. Stealth detectors use digital signal processing technology and have high sensitivity levels to ensure the detection of the smallest ferrous, non-ferrous and stainless steel contaminants. The built-in data collection software with USB connectivity establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Automatic Calibration Function oH Meter
AH-151
-
The pH meter AH-151 with automatic calibration function performs pH measurement by automatically cleaning the electrode with cleaning solution and performing calibration with standard solution, making it possible to drastically reduce maintenance work. In addition, by spraying the calibration solution, the consumption of calibration solution has been reduced. The spray amount of the cleaning solution can also be adjusted according to the condition of contamination, which contributes to cost reductions. With periodic cleaning and calibration, stable and highly reliable pH measurements are possible.
-
Product
Universal Differential pH Water Quality Sensors
SD7500CD
-
Continuous online pH monitoring in wastewater and coating industrial applications leads to contamination and eventually requires sensors to be replaced. A differential pH sensor utilizes a measurement technique designed to extend the working lifetime of sensors in challenging applications. Replacing the sensor reference (salt bridge) and buffered electrolyte solution can prevent sensor replacements, saving time and money. Our SD7500 Series features a combination sensor output; these differential pH sensors can be used with any conventional pH/ORP transmitter.
-
Product
Low-Noise DC Bias
-
Imaging devices, such as CCDs, IR FPAs, and CMOS image sensors, require DC bias with very low electrical noise to prevent contamination of the image. Image quality can also be enhanced by carefully tuning each bias voltage to extract the maximum signal/noise ratio out of an array. Pulse Instruments has decades of experience providing DC bias supplies with the flexibility required tocharacterize and test a variety of devices while maintaining the noise immunity required for satellite and astronomy applications.
-
Product
Atmospheric Pressure Gas Analyzers
-
The Cirrus™ single-quadrupole mass spectrometers are powerful analytical tools for a wide range of laboratory and industry-based gas analysis applications. The Cirrus family, featuring the Cirrus™ 3 and Cirrus™ 3-XD atmospheric pressure gas monitoring systems are ideal for analysis of bulk gas, gas composition, and detection of trace gasses and contamination. These powerful, versatile and customizable platforms, when combined with Process Eye™ Professional software and its recipe-based control, can significantly boost your productivity.
-
Product
Ammonium Logger Sensor
NUL-240
-
The NeuLog ammonium sensor can be used to measure the concentration of ammonium ions (NH4+) in aqueous samples. It can be used to evaluate the degree of contamination of water due to the use of fertilizers.Ammonium measurements can also be very relevant to study the nitrogen cycle in general and to relate this cycle to plants and algae.
-
Product
High Voltage Inclined Plane And Erosion Tester
-
SCR ELEKTRONIKS have developed HIGH VOLTAGE INCLINED PLANE AND EROSION TESTER to carryout test specified in many standard to cover test method for the evaluation of the relative tracking and erosion resistance of insulating solid using liquid contaminant (ASTM D2303). Perform the Initial Tracking Voltage Test, Time to track Test, And Erosion Test as per selection.
-
Product
Automated Monitoring of Airborne Molecular Contamination
AMC-Monitor T-1000
-
The all-in-one analyzer for FOUP, fab and clean-room environment AMC monitoring in the semiconductor industry. The AMC-Monitor is a modular and flexible platform for airborne molecular contaminations (AMC) monitoring in semiconductor applications such as: FOUP analysis with a focus on VOC and condensables incl. full integration with Pfeiffer Vacuum APA 302 pod analyzer. Clean-room monitoring in fabrication plants.
-
Product
Portable Particle Monitor
iCountOS
-
The iCountOS is a highly rugged portable particle size monitor that can be used for measuring contamination levels in fuels and/or hydraulic fluids. Capable of operation online (direct connection to system) or offline (sampling from tank or reservoir).
-
Product
Ozone Gas Delivery Systems
-
MKS ozone gas delivery systems provide field-proven, high concentration, ultra-clean ozone generation for advanced thin film applications such as Atomic Layer Deposition (ALD), Chemical Vapor Deposition (CVD), Tetraethyl Orthosilicate (TEOS)/Ozone CVD (HDSACVD), contaminant removal and oxide growth. Gas delivery models have integrated ozone concentration monitoring, flow control, and power distribution. Additional system options include safety monitoring, status indicators and ozone destruction capability.
-
Product
Oil Tan Delta Test Set
-
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.
-
Product
AEROTRAK™ Handheld Particle Counters
9306
-
The TSI AEROTRAK™ Handheld Particle Counters offer the most features and flexibility for customers interested in low cost and versatile particle contamination monitoring.
-
Product
Switch Mode Power Supplies-Water Cooled
-
The MSW Rectifiers are based on Switch Mode Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%.The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.
-
Product
PXI Automotive Switch Simulator Modules
-
Pickering's Switch Simulator Modules are designed for automotive test applications. These modules simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. They allow automotive I/O devices to be tested for correct operation under adverse conditions.
-
Product
IGBT Power Supplies - Air Cooled
-
CEHCO The MSA1000 Rectifiers are based on IGBT Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%. The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.
-
Product
AOI Handlings System
-
The AOI handling system is a compact facility with various test units. Via an ionization cleaning station the ceramics are transferred to the contacting station. There, the resistance values of the substrates are tested with a rigid needle adapter. Afterward, the ceramics are further conveyed to the three (optionally four) AOI test stations (for automatic optical inspection) and are tested for cracks, unevenness, faulty imprints, contamination, etc. The poorly evaluated ceramics arrive at a review station where the operator can assess and evaluate the errors on the monitor. If the operator is uncertain about a fault, the ceramic in question can be positioned under the microscope position and inspected by eye. Poorly defined ceramics are marked accordingly with an ink pen.
-
Product
Extreme Environment Sensors
-
For high pressure, low temperature, and high temperature applications* For applications requiring high accuracy, high reliability, and structural integrity.* Operating temperatures from -320°F to +1000°F (+1200°F short term).* Displacement systems withstand pressures up to 3500 or 5000 psi.* Dual-coil sensor design effectively minimizes radiation effects.* Hermetically sealed and laser welded.* Unaffected by environmental contaminants.





























