Precision Current Sources
-
Product
Noise Source, 10 MHz to 26.5 GHz, nominal ENR 15 dB
346C
Noise Source
The Keysight 346C noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 26.5 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. Option K01 is a coaxial noise source and features coverage from 1 to 50 GHz with a 2.4 mm coaxial connector.
-
Product
USB Smart Noise Source, 10 MHz to 26.5 GHz, Nominal ENR 15 dB
U1831C
Noise Source
The USB-powered U1831C provides broadband noise figure measurements from 10 MHz – 26.5 GHz with modular signal analyzer and benchtop X-Series signal analyzers.
-
Product
Four-Port Tunable Laser System Source
N7714A
Laser Source
The Keysight N7711A and N7714A tunable lasers are single-port and four-port sources, available with C-band or L-band wavelength coverage. The narrow linewidth and offset grid fine-tuning capability make them ideal sources for realistic loading of the latest transmission systems. All models can reach any wavelength point within their specified wavelength range just like all other Keysight tunable lasers. In this mode, code compatibility with existing test setups based on Keysight's range of full-size and compact tunable lasers is a great asset. In system loading applications, it may be preferable to grid-tune the lasers like system transmitters, simply by changing the channel index. The channel grid is adjustable to standard ITU-T grid spacing like 50 GHz, and to arbitrary grids. Likewise, the zero frequency (base channel) of the chosen grid is adjustable. A 12 GHz fine-tuning range allows de-tuning the frequency.
-
Product
30 A Current Shunt
34330A
Current Shunt
Measure current safely with this precision 0.001 ohm resistor housed in a plastic case surrounded by epoxy.
-
Product
Noise Source, 1 GHz up to 40 GHz
346CK40
Noise Source
The Keysight 346CK40 is the ideal companion to Keysight´s noise figure solutions when working on high frequency applications. Since it is broadband (1 GHz to 40 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source greatly reduces measurement uncertainty, which are commonly reflections of the test signals. This is a coaxial noise source with a 2.4 mm coaxial connector. ENR typically 14 dB at 1 GHz, decreasing to 5 dB at 40 GHz (typical).
-
Product
HPC High Current Probes, 100 – 187 mil (2.54 – 4.75 mm)
HPC
High Current Probe
100 – 187 mil (2.54 – 4.75 mm)
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-023
Precision Resistor Module
The 40-297A-023 (PXI) and the 42-297A-023 (PXIe) are 9-channel programmable resistors with a range of 1.5 Ω to 3.55 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Rogowski AC Current Probe, 23 MHz, 3000 A
N7040A
High Current Probe
The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.
-
Product
NI-9247, 50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module
783589-01
Current Input Module
50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9247 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
Source Measure Unit
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-033
Precision Resistor Module
The 40-297A-033 (PXI) and the 42-297A-033 (PXIe) are 9-channel programmable resistors with a range of 2 Ω to 52.4 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-136
Precision Resistor Module
The 40-297A-136 (PXI) and the 42-297A-136 (PXIe) are 4-channel programmable resistors with a range of 2 Ω to 395 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
PXIe 5-channel Precision Source/Measure Unit, 500 kSa/s, 10 pA, 30 V, 500 mA
M9615A
Source Measure Unit
The Keysight M9615A is a PXIe five-channel precision source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 uV / 10 pA.
-
Product
SNS Series Noise Source 10 MHz to 18 GHz (ENR 15 dB)
N4001A
Noise Source
The SNS series N4001A noise source is ideal for general purpose use with a low reflection coefficent and a nominal ENR of 15 dB from 10 MHz to 18 GHz.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-146
Precision Resistor Module
The 40-297A-146 (PXI) and the 42-297A-146 (PXIe) are 3-channel programmable resistors with a range of 2.5 Ω to 5.82 MΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-124
Precision Resistor Module
The 40-297A-124 (PXI) and the 42-297A-124 (PXIe) are 4-channel programmable resistors with a range of 1.5 Ω to 6.97 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Noise Source, 10 MHz to 18 GHz, nominal ENR 6 dB
346A
Noise Source
The Keysight 346A noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 18 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. The very small change in reflection coefficient (<0.01) from ON to OFF is designed especially for accurate characterization of input-impedance-sensitive devices (like GaAsFETs and many UHF amplifiers).
-
Product
Source Measure Units and LCR Meters
Source Measure Unit
Source Measure Units are high-precision, high-accuracy DC instruments that can both source and simultaneously measure voltage and current. Additionally, LCR Meters can measure the inductance, capacitance, and resistance (LCR) of electronic equipment.
-
Product
High-Voltage Differential Probe, 25 MHz
N2791A
High Current Probe
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-110
Precision Resistor Module
The 40-297A-110 (PXI) and the 42-297A-110 (PXIe) are 9-channel programmable resistors with a range of 1 Ω to 31 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Precision Source / Measure Unit (2 Ch, 100 FA)
B2902B
Source Measure Unit
The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
MLC Monolithic Laser Combiner
Laser Source
Keysight monolithic laser combiner products deliver unmatched innovation in confocal, super resolution, and fluorescence microscopy research. The fixed mounting system guarantees that the laser combiner is permanently aligned for the life of the product. The result is a stable, reliable, and easy-to-use plug-and-play system that's always ready to go when you are.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-041
Precision Resistor Module
The 40-297A-041 (PXI) and the 42-297A-041 (PXIe) are 6-channel programmable resistors with a range of 2.5 Ω to 201 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-050
Precision Resistor Module
The 40-297A-050 (PXI) and the 42-297A-050 (PXIe) are 6-channel programmable resistors with a range of 3 Ω to 1.51 MΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
C Series Voltage And Current Input Module
Current Input Module
The C Series Voltage and Current Input Module features up to 16 input channels with built-in noise rejection. You can use this module to combine the two most common inputs to reduce the overall number of modules you need in your measurement system.The C Series Voltage and Current Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-021
Precision Resistor Module
The 40-297A-021 (PXI) and the 42-297A-021 (PXIe) are 9-channel programmable resistors with a range of 1.5 Ω to 925 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Precision Source / Measure Unit, 1-Channel, 10 FA Resolution, 210 V, 3 A DC / 10.5 A Pulse
B2911B
Source Measure Unit
The Keysight B2911B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
NI-9207, 500 S/s, 16-Channel C Series Voltage and Current Input Module
781068-02
Current Input Module
500 S/s, 16-Channel C Series Voltage and Current Input Module - The NI‑9207 is a combination voltage and current input module designed with industrial systems in mind. It features eight current and eight voltage input channels, with built-in noise rejection.
-
Product
PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit
782431-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.





























