Product
Source Measurement Unit
SMU32
Source Measure Unit
The SMU32 is a low cost solution for V/I source and measurement. The SMU32 offers PMU/DPS in a compact, 3U PXI form factor. The SMU32 supports -1V to +10V +- 32 mA FVMI/FIMV modes. 8~32 PMUs can be ganged to DPS for high current driving.
-
Product
Signal, Insert, Receiver, QuadraPaddle, SIM, Pass-Thru, 4 Pos, 1 Slot
510180105
SIM Insert
Signal, Insert, Receiver, QuadraPaddle, SIM, Pass-Thru, 4 Pos, 1 Slot.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-301
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Source Measurement Unit
SMU8
Source Measure Unit
The SMU8 offers high voltage SMU in a compact, 3U PXI / USB form factor. The SMU8 supports 0V to +4V 0.5A or 0V to +12V 25.6mA with FVMI, FVMV, FIMV, FIMI modes. 8 channel can be ganged to support high current driving.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
Tool, Insertion, Vertical VTAC, I2MX
910112134
Insert Tool
Tool, Insertion, Vertical VTAC, i2MX
-
Product
Pin Insertion Tool For Scorpion Connectors With Crimp Pins
C020AFR-2CP-2A-I
Insert Tool
Extractor tool for crimp pins fitted into a Scorpion connector housing.
-
Product
VTAC Insert, Receiver/ITA, SIM (Only Available In Patchcords)
610151101
VTAC Insert
VTAC Insert, Receiver/ITA, SIM (Only Available in Patchcords)
-
Product
Tool, Insertion, Vertical VTAC, VTAC SIM Modules
910112133
Insert Tool
Insertion tool for Vertical VTAC inserts. Tool layout is designed for use with 90 Series VTAC SIM Modules.
-
Product
Tool, Insertion, Right Angle, VTAC
910112132
Insert Tool
Used to install VTAC Right Angle inserts (p/n 610151104) onto a PCB.
-
Product
Signal, Module Insert, ITA, i2 MX, TriPaddle ,33 Position
510144006
ITA Module Insert
Signal, Module Insert, ITA, i2 MX, TriPaddle ,33 Position.
-
Product
Dual Function Slot MOSA Data Concentrator Unit (DCU)
NIU2A-DCU-01
Data Concentrator Unit
NIU2A-DCU-01 is a Modular Open Systems Approach (MOSA) Data Concentrator Unit with low power high performance ARM Cortex -A9 processing. 512 MB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet and optional Fiber Optic Ethernet support
-
Product
3U OpenVPX Sensor Interface Unit
SIU34
Sensor Interface Unit
The SIU34 is a highly configurable rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, communications, Ethernet switching and processing. The SIU34 leverages NAI’s 3U OpenVPX™ boards to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
USB Modular Source Measure Unit
U2722A
Source Measure Unit
The U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
PXIe-4145, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit
782435-01
Source Measure Unit
PXIe, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit - The PXIe-4145 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4145 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4145 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
PXI Source Measure Unit
Source Measure Unit
PXI Source Measure Units (SMUs) combine high-precision source and measure capability with features designed to reduce test time and increase flexibility. These features include high channel density for building parallel SMU test systems, deterministic hardware sequencing for minimizing software overhead, and high-speed update and sample rates for quickly changing setpoints and acquiring data. Additionally, the flexible sampling rate and streaming capability of PXI SMUs allows you to use the instrument as a digitizer to capture transient behavior, and the digital control loop gives you the ability to adjust the transient response of the instrument. The ability to change the transient behavior of the SMU, called SourceAdapt, reduces SMU settling time and minimizes overshoot and oscillations, even with highly capacitive loads.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
PXIe-4142, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit
782430-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit - The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
Source Measure Units and LCR Meters
Source Measure Unit
Source Measure Units are high-precision, high-accuracy DC instruments that can both source and simultaneously measure voltage and current. Additionally, LCR Meters can measure the inductance, capacitance, and resistance (LCR) of electronic equipment.
-
Product
High Precision Source Measure Unit (SMU) - Hybrid Compatible PXI, 100ks/S Programming/Measurement Speed
52400 series
Source Measure Unit
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-194A-002-HI
Fault Insertion Unit
The 40-194A-002 is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PCI Fault Insertion Switch Cards
-
Pickering's PCI Fault/Signal Insertion Switch Cards feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect all of which can simulate connectivity problems in the system.
-
Product
High-Resolution Precision SMU (10 FA, 210 V)
PZ2110A
Source Measure Unit
The Keysight PZ2110A is a precision source / measure unit (SMU) that expands precise measurements from conventional static measurements and pulsed measurements, to fast dynamic measurements. It is ideal for a wide variety of current versus voltage (IV) measurement tasks that require both high resolution and accuracy. The PZ2110A can accurately perform characterization, parametric tests, and reliability tests of semiconductors, active / passive components, and general electronic devices.
-
Product
Source Measurement Unit
SMU4
Source Measure Unit
The SMU4 offers high voltage DPS in a compact, 3U PXI form factor. The SMU4 supports -20V to +20V 100mA with FVMI, FVMV, FIMV, FIMI modes.
-
Product
PXI 1A Fault Insertion Switch 11-Channel
40-195-101
Relay
The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.
-
Product
20/26 Ghz Coax, Module Insert, Receiver, i2 MX, 5 Position
510143008
Receiver Module Insert
20/26 Ghz Coax, Module Insert, Receiver, i2 MX, 5 Position.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-193A-002-HI
Fault Insertion Unit
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.