Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Field Strength Meter
FIM-72A UHF
The Model FIM-72A is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-72A is suitable for practically all types of RF emission measurements in the 450 MHz to 960 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and meter dynamic range of either 20 dB or 60 dB. A dc analog voltage, proportional to meter indication, is provided for driving a chart recorder or similar device. A leveled output from the calibrating generator is available for measuring cable insertion loss, filter response, amplifier gain, VSWR, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.
-
product
Voltmeter
PM-422B RF
RF VOLTMETERS. Panel Mounted. Portable Cabinet Available. Ease of Calibration
-
product
Mobile sound Level Meter
SoundMeter
SoundMeter turns your iOS device into a handheld sound level meter (SLM) with support for exponential-time-weighted sound level (Lp) and equivalent sound level (Leq) measurements with various time and frequency weightings. The built-in signal generator tool can be used for generating calibration test tones, noise, chirps, or other periodic signals. SoundMeter also offers additional tools via in-app purchase, including a Noise Dosimeter and a whole or 1/3-octave real-time analyzer.
-
product
Spectrally Flat Class B Pyranometer
LPPYRA02… Series
Spectrally Flat Class B (First Class) pyranometer according to ISO 9060:2018. The LPPYRA02 are well suited for the measurement of incoming global solar radiation (0.3μm…3μm spectral range). Complete with: shade disk, sachet with silica-gel crystals, 2 cartridges, levelling device and calibration report.
-
product
Field Strength Calibration Probe
Beijing KeHuan Century EMC Technology Co,.LTD
Three-axis omnidirectional 100kHz~6GHz light transmission.
-
product
ECU Calibration
Designing an Electronic Control Unit (ECU) is only the beginning. The features in ECUs, such as Powertrain Control Units, are quickly becoming more complex and offering more features. Thousands of variables are now provided for the engineer to modify during the in-vehicle calibration phase, and fine tuning them is as complicated as it is critical. Calibration tools significantly impact the efficiency and effectiveness of the ECU development process. These tools are typically comprised of PC-based software to perform the adjustment of the variables and an ECU hardware interface to provide the connection of the software to the controller. Teams must be able to measure and time-align relationships of inputs and outputs and make real-time modifications.
-
product
Test Equipment Calibration
ISO:17025 AccreditedANSI Z540-1-1994 AccreditationA2LA Certificate 2374.01
-
product
Ultrasonic Level Transmitter
USonic
The Drexelbrook family of Ultrasonic technology level products offers an affordable two wire and line powered version for non-contact level measurement of liquids and slurries for level, distance, volume and open channel flow.Measurements of level, distance, volume and open channel flow is easily configured through the menu driven display. The Usonic level transmitter is offered with a two wire 4-20 mA, Hart output signal and is suitable for all Class I Div. 1, Zone 0, I.S. or XP locations. The bench configuration eliminates the need to move process material levels for calibration.
-
product
Relay Testing Kits
KINGSINE Electric Automation Co., Ltd.
Universal Relay Test ApplicationsComplied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc100/1000Mbit Fiber port for SMV and GOOSE simulations6x35A & 4x310V independent high burden output channels13 channels independent low-level signal outputsAC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)Transducer calibration (0.02 class)
-
product
True RMS Power Sensors
LadyBug True RMS Average Power Sensors deliver reliable, accurate power measurements for CW, Pulse, and modulated signals. These diode based sensors feature a wide dynamic range and a great VSWR. The optional external triggering input feature can be used without any external components. Recorder and Trigger outputs are also available. Our patented NoZero NoCal technology make these sensors ideal for calibration systems, automated test stations and other embedded applications.
-
product
Beacon Transmitters for Radio Amateurs
Is a radio beacon, whose purpose is the investigation of the propagation of radio signals. Most radio propagation beacons use amateur radio frequencies. They can be found on LF, MF, HF, VHF, UHF, and microwave frequencies. Microwave beacons are also used as signal sources to test and calibrate antennas and receivers
-
product
Spectroscopic Reflectometer
SR Series
Angstrom Sun Technologies, Inc.
Spectroscopic reflectometer (SR) tools are relative low cost and easy to use. To ensure accurate measurement on spectra, a long working distance and also adjustable working distance set up are professionally designed and considered. Since reflection spectra measurements require to use known reference to calibrate light intensity, it is hard to image that user could get accurate spectra without optimizing signal during such calibration because reference thickness is different from sample substrate's thickness in most of cases. Adjusting power output to lamp is our another consideration in ensuring a good measurement by reducing non-linearity effect of the detector.
-
product
Load Cell Indicator
Morehouse Instrument Company Inc.
This indicator can read mV/V and use free, custom Morehouse software to convert the mV/V units to engineering units with coefficient files from ASTM E74 or ISO 376 reports. This meter is often the choice for accredited calibration service providers that want high accuracy and convenience but do not want to break the bank.
-
product
Waterproof and Dustproof Portable pH Meter
CyberScan pH 300
Multi-Point Push-button Calibration (up to 5/6 points) with Auto-Buffer Recognition - choice of USA, NIST or DIN buffer standards for quick calibration with no calibration mistakes
-
product
Toxic Gas Detector
SMC 5100-XX-IT
The SMC 5100-XX-IT gas detector monitors toxic gases such as Hydrogen Sulfide, Carbon Monoxide, Nitrogen Dioxide, Ammonia, Oxygen Deficiency, and others. The detector requires calibration only every six months, cutting operating costs and time.
-
product
RTD Simulator PCI Card 6-Channel PT1000
50-262-102
This RTD Simulator is a PCI card that supports 6 channels of RTD simulation. The card can provides a setting resolution of <90mΩ (also available in <8mΩ - PT100) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
Waterproof Portable conductivity meter
CyberScan CON 400
Waterproof and dustproof to IP67 Deliver lab-accurate results stamped with time and date for GLP-compliant researchConveniently auto-ranging with up to 5-point push button calibration
-
product
Turning Mirror
10769A
The 10769A is ideal for use in laser measurement and calibration applications. In the calibration of slant bed lathes, for example, the beam steering mirror deflects the beam from the laser head upward, through the interferometer, along the lathe's cross slide. One or more mirrors can also create a path from a laser head to an interferometer located in an otherwise inaccessible position, as in the case of a milling machine with a table that moves in only one axis.
-
product
Premier Industrial Shakers
The Hardy Shaker ensures that the Seismic Sensors and Transmitters that you have installed are working properly and giving you the results you need. Just like the pressure and flow instruments in your facility need calibration checks every year, so do your Seismic Sensors and Transmitters. This system puts the calibration check of those Seismic Sensors and Transmitters within your control, and within your budget.
-
product
Microvolt DC Volt Meter
QA350
The QA350 relies on a built-in reference to calibrate the ratio between the hi and low ranges. If you have a preferred lab reference, you may use that it to improve the QA350 accuracy beyond the indicated +/- 400 PPM. For example, various vendors on eBay can provide calibrated +/-30 PPM 5 or 10V voltage references that can be used to set the ultimate accuracy of the QA350 to under 50 PPM at room temperature.
-
product
Calibration Services
We offer a full range of calibration services and repairs. Our Indianapolis calibration laboratory is accredited in accordance with the recognized international standard ISO/IEC 17025 (2017) and meets the requirements of ANSI/NCSL Z540-1994-1. Alternatively, our network analyzers and calibration kits can be calibrated by any ISO17025-accredited and Z540-1 compliant calibration lab worldwide.
-
product
Hydrophone
RESON TC 4033
The TC4033 provides uniform omnidirectional characteristics within the full frequency range of 1Hz to 140kHz. The Typical sensitivity of -203dB re 1V/µPa and the capacitance of 7nF, ensure an excellent signal to noise ratio, thereby allowing TC4033 to be used with extension cables with only a limited reduction in sensitivity. The TC4033 offers excellent acoustic characteristics and durability, which makes it ideal for a wide range of applications and for calibration purposes.
-
product
Calibration Executive Software
CalEasy Series
CalEasy is a full-featured, Calibration Executive software package that supports the verification and calibration of Marvin Test Solutions instruments. The software is intended for use by users that prefer to perform in-house calibration and verification for their Marvin Test Solutions instruments. By calibrating or verifying the instrument in-house, the time and cost associated with returning an instrument to Marvin Test Solutions for calibration service can be eliminated or reduced. CalEasy is also used internally by Marvin Test Solutions production to perform initial calibration and to recalibrate the instrument when received for service. This ensures that user and factory based calibration performance is similar. Depending on the specific instrument, standards instrumentation supported for calibration / verification includes a DMM, and a frequency standards module. Some modules require the use of matrix switch card.
-
product
Diode Power Sensor
8487D
Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 50 MHz to 50 GHzDiode power sensing element
-
product
Rope Testers
The LMA Signal measures loss of metallic cross-sectional area (LMA) caused by corrosion, abrasion, etc. The LMA Signal is quantitative and can be calibrated. (Typically, a rope must be retired when the LMA exceeds 10%).The WRR Signal measures wire rope roughness (WRR). WRR is defined as the aggregate surface roughness of all wires in a rope. WRR is typically caused by and indicates internal and external corrosion pitting, broken wires and clusters of broken wires. The WRR signal is quantitative, and it is calibrated together with the LMA Signal.The LF Signal can indicate localized flaws (LF), for example, broken wires, corrosion pitting, etc. Because it is only qualitative - and cannot be calibrated - it is of limited value for assessing rope deterioration and for making rope retirement decisions.
-
product
Measurement Microphones
All microphones are omni-directional and 48V phantom powered. The XL2 Analyzer microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the XL2 automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
-
product
Wavelength Meters - Scientific
Bristol Instruments'' wavelength meters are for scientists and engineers who need to know the exact wavelength of their lasers. These systems use proven interferometer-based technology to measure absolute wavelength to an accuracy as high as 0.0001 nm. To achieve the reliable accuracy that is expected from Bristol Instruments, all of its wavelength meters include a built-in wavelength standard for continuous calibration. Systems are available for CW and pulsed lasers that operate at wavelengths from 350 nm to 12 m.
-
product
Digital ESU Analyzer
ESU-2050P
Calibration quality analyzer; uses external precision non-inductive test loads and wide band current transformer. The Pulsed Model is compatible with all continuous output generators (same as standard model), plus generators with pulsed output waveforms.
-
product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm
CK519A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.





























