Preamplifiers
Detect and strengthen a signal prior to greater amplification.
See Also: Amplifiers, RF Amplifiers, Current Amplifiers, Audio Amplifiers, Voltage Amplifiers, Transconductance Amplifiers, Op Amps, Klystron, Instrumentation Amplifiers, Distribution Amplifiers
-
Product
Microphone Preamplifier
HT426E01
-
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
Product
Energy Probes
RjP-700 Series
-
The RjP-700 Series probes are designed to measure lower pulse repetition rate, longer duration pulses - up to 1msec pulse width at a maximum rep rate of 40Hz. This allows for measurement of pulsed flashlamps and other sources not possible with other probes. The combination of large area detector surface and long pulse width allow for measurements up to several Joules total energy. Integrated preamplifiers allow for longer probe-to-instrument cable runs, useful for manufacturing environments.
-
Product
Power modules
-
G.R.A.S. Sound & Vibration A/S
It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation
-
Product
Probes For Non-Contact Ultrasonic Testing
SONOSCAN CFC / CF
-
Due to the strong damping properties of air, low frequencies in the kHz range are used in air-coupled ultrasonic testing. It is therefore all the more important that the ultrasonic transducers offer a particularly high sensitivity in order to ensure high penetration and improved resolution. We achieve this, among other things, by installing preamplifiers in the receiver probe as well as by using our own Piezocomposite Technology, which enables a flexible use of the matching materials in our CFC and CF probes.
-
Product
Hydrophone
TC 4037
-
Incorporating a 10dB low-noise preamplifier able to drive a 25-metre cable and a wide usable frequency range, the TC 4037 is a spherical probe hydrophone that’s ideal for measuring sounds in the 100 to 500kHz range.
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.





