Sound Calibrators
assure sound measurement accuracy.
See Also: Sound Calibration, Acoustic Calibration
-
product
Sound Level Meter
The Sound Level Meter is shown positioned near the top of the main Daqarta window. Like the Voltmeter and Frequency Counter, it can be positioned anywhere on the screen, and the size of the display font changes when you resize the meter by dragging its borders. You can fill the screen for a really big readout that can be seen from across the room.
-
product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (m) 50 Ohm
CK518A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Electrical Calibration
We offer electrical calibration on a wide range of instruments covering all brands and types of electrical testers. Being the only calibration company in Ireland to have Fluke's state of the art 5320a Multi-product calibrators allows us to match or in many cases exceed the manufactures calibration such as Fluke, Megger, Kewtech etc, but for a lot less cost and downtime to you.
-
product
Automatic Calibration Module
ACM4509
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
product
Temperature Calibration
Trescal provides full Temperature Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Temperature Calibration services can be delivered at your site or at our lab. Accreditations for our temperature calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
SPL Calibrator -124 dBSPL @ 1 kHz
511ES124
The 511ES124 is designed to provide 124 dBSPL at 1 kHz to meet the needs of the low sensitivity microphones found in many high SPL measurement applications. The microphones used in Car Stereo competitions like dB Drag racing, IASCA, and USAC have had their sensitivities reduced to the point where 94 dBSPL may no longer be adequate for calibration.
-
product
Bond Force Measurement And Calibration Systems
BFS-20
Based on its design and easy handling it can be used also on other brands to measure the bond force.
-
product
TV-SAT Generator with Stereo Sound and Teletext
TRF-598
Desktop television generator TRF-598 is universal and multistandard equipment suitable for TV systems PAL, SECAM, NTSC and all its substandards. Generator supports 4:3, 16:9 and 14:9 picture formats and interlaced & non-interlaced mode. This instrument is capable to generate special television test signals, including so-called „Anti-PAL”.
-
product
Datalogging Digital Sound Level Meter with RS-232 Software and Cable
735
Whether you are testing for OSHA compliance, quieting equipment, or monitoring the roar of a stadium crowd, B&K Precision's Sound Level Meters can get the job done. The model 735 Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting.
-
product
Calibration Devices For Spring Impact Hammer
CX-TF06A
Shenzhen Chuangxin Instruments Co., Ltd.
Calibration Devices for Spring Impact Hammer
-
product
Large Calibre Barrel Bore Gauge System
BG20
Aeronautical & General Instruments Ltd.
The BG20 has been specifically designed to modernise and improve the inspection routines of large calibre barrels. A two-point measuring head is supported in the barrel or chamber by a clear disk which facilitates the angular alignment of the head and the location of a suspected defect.
-
product
Calibration
General purpose calibration/diagnostic tool.Built in precision resistors.Simple manual contact/routing/resistor selection.4mm terminal posts on key device connections.In line mode to aid fixture wiring/DUT debugging.Comprehensive documentation including circuit schematics.Connecting cables.
-
product
Network Analyzer N-Port Calibrated Measurements
S93551B
The S93551B adds a multiport analyzer mode that enables full N-port error correction and measurement capabilities using an external test set.
-
product
Small Class 1 Sound Level Meter
SVAN 971
The instrument's new user interface makes both configuration and measurement easier than ever before. For those who don't have time to work with measurement settings, SVAN 971 offers extremely simple operational mode with Start/Stop.
-
product
Handheld Economic Process Calibrator
VA702
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This Multifunction calibrator combined voltage. current .resistance .thermocouple temperature .RTD in one device.
-
product
Electrical Calibration
Beijing GFUVE Electronics Co.,Ltd.
Checking condition , performance , sensitivity and accuracy of any electrical device.
-
product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL DU
The 72-7770 CAL DU from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
product
Temperature Calibration
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
product
Argon Calibration Source
AR-1
The AR-1 produces low-pressure argon emission lines from 696-1704 nm for use in performing fast, reliable spectrometer wavelength calibrations.
-
product
Very High Temperature Calibration System
BBS-VH
The 'True' Black Body - Range 500 to 1300°C, Resolution 1°C, Accuracy <0.3% reading, Stability ±0.5°C, Aperture Ø 25 mm, Emissivity better than 0.99, Semi-Portable
-
product
Sound Level Meters
Optimus
The Optimus Sound Level Meters are a range of high performance sound level meters that use the very latest technology to provide you with a simple and accurate tool to measure and record noise levels. Combining the latest digital technology with ease of use. Class 1 & Class 2 to IEC 61672-1:2013 & IEC 61672-1:2002. High performance guaranteed - Class 1 & Class 2 Sound Level Meters.
-
product
Temperature Calibration Software v5.1
MET/TEMP II
MET/TEMP II software allows you to easily automate the calibration of a wide range of temperature sensors. It provides a comprehensive temperature calibration solution that allows you to test large quantities of sensors, calculate characterization coefficients, and print calibration reports. You can standardize comparison or fixed point calibrations and use multiple temperature sources or references in one test.
-
product
Acceleration Pickup Calibrator
VX-1100A
VX-1100 is for a piezoelectric type accelerometer which is widely used for measuring vibration. This compact calibrator is effective for checking operation(sensitivity) sensors before measurement to acquire accurate data.Built-in sensor amplifier and display in one unit allows direct reading of the sensitivity. This calibrator excites the sensor at a frequency of 159 Hz and acceleration of 10 m/s2 rms, and the sensor outputs can be used as calibration signals for a vibration measuring system.
-
product
Screen Channel Sound Solution For Direct View Displays
Ultra Reflex
Cinema technology is always in motion. A new generation of large-scale direct view displays offer high dynamic range, extraordinary contrast ratios, tonal detail, and flexible color space. But because direct view displays are solid, speakers cannot be placed behind them to localize sound to the action onscreen. The patent-pending Meyer Sound Ultra Reflex system is the first screen channel loudspeaker solution to provide precise localization for direct view displays.
-
product
Calibrated Diffuse Reflectance Standards
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications





























