Gas
1) fills any space it's contained in and is amorphous. 2) liquid fuel powering vehicles.
See Also: Dissolved Gas, Gasoline, Ammonia
-
Product
Gas Flow Analyzer
venTest
-
venTest is designed to accurately test the performance of Ventilators and Anaesthetic systems.
-
Product
Manual Fixture Kit With Mass Interconnect Cassette Interface, Max number of probes (2N) 1000 units, Max UUT 580 x 250 mm (wxd)
CMCSK-03-01
-
Linear click system with ball bearings, using gas springs.10 mm ESD-proof top cover with aluminum reinforcement bars.Steel base cabinet with detachable aluminum back and bottom panels.Detachable interchangeable case system with an 8 mm spring-loaded probe protection cover.Base cabinet fitted with a telescopic guide rail and catch.
-
Product
OEM Gas Analyzers
-
Reduce gas measurement costs with modules that measure multiple gases and eliminate field calibration. Our Andros OEM gas modules lead the way in non-dispersive infrared (NDIR) gas analysis for automotive emissions and patient monitoring.
-
Product
Emission Measurement Technology
-
Maschinenbau Haldenwang GmbH & Co. KG.
When measuring exhaust gas, the CO concentration or - in diesel vehicles - the smoke gas opacity is measured. In this way it can be determined whether the exhaust system meets the legal requirements and is in perfect condition.
-
Product
Sensors
-
Parker’s sensor and related offerings include pipeline gas temperature measurement solutions; electroactive polymer (EAP) technology sensors for measuring mechanical or thermally induced strain; RTD probes for reducing thermal coupling errors from thermowells; threaded, flanged, socket weld, weld-in, and Van Stone thermowells; vacuum pressure sensors; and wireless sensors, among other products.
-
Product
Mid-Range Chemiluminescence Oxides of Nitrogen Analyzer
Model T200M
-
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers. The T200M may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
IR Emitters and Controllers
-
Opto Diode manufactures five families of infrared emitters that are used for a variety of medical and industrial applications, including gas analysis, environmental monitoring, spectroscopy, and process control. From the steady state (DC) emitters (SA Series), to high-power steady state emitters (SHA Series), to pulsable sources of black-body radiation (SVF Series) and fast pulsable sources of black-body radiation (SPF Series), to high-speed IR emitters with integrated drive electronics (PIREPLUS), we have the perfect family of products for your critical requirements.
-
Product
Oil Well Cementing
-
Chandler Engineering has produced the highest quality Oil Well Cementing instruments for the Upstream Oil & Gas Industry. Today, Chandler Engineering, the industry's largest instrument supplier continues its effort to help customers improve the efficiency and productivity of their drilling and production operations.
-
Product
Paragon® 8.0 Slm NF3 Flow Intelligent Remote Plasma Source
-
For cleaning CVD and ALD/ALE process chambers, the Paragon remote plasma source is designed for high gas dissociation rates (> 98%) of NF3 with gas flows up to 8 slm and pressures up to 10 Torr. This leading-edge performance translates into increased process throughput and repeatable process results. The Paragon design incorporates a proprietary plasma block design with a Plasma Electrolytic Oxidation coating for low particle, long block life that delivers lower cost of ownership.
-
Product
Digital Ultrasonic Testing Device
SONAPHONE
-
The ultrasonic leak detector SONAPHONE is designed for a quick and precise location of leaks in compressed air, inert gas and vacuum systems. System leaks can easily be detected. The variety of devices in the range and the extensive accessories available enable this range of devices to be used for a multitude of various applications. With the help of the ultrasound testing device SONAPHONE, it is easy to pinpoint leaks.
-
Product
Vacuum Quality Monitor Systems
-
The 835 VQM is a mass spectrometer that operates from UHV to 10-5 Torr and accurately measures the gases in the vacuum chamber. The 835 VQM Differential Pump System delivers the advantages of the 835 VQM at higher pressures. The VQM system consists of an autoresonant ion trap mass spectrometer gauge, a VQM Controller and VQM Viewer software that that converts raw data into actionable information. The system is ratiometric, meaning that it determines the ratio of each gas to other gases in a vacuum chamber. It is usually coupled with a total pressure gauge to provide partial pressures of each gas as indication of the quality of the vacuum in the chamber.
-
Product
Gas Analyzers
-
Independent Handheld 5 Gas Analyzer or use with MODIS™ Link, VERDICT® and VERUS® Bluetooth® link. Fully Portable 5 Gas Analyzer, go anywhere, use anywhere 110 V AC and 12 V powered Internal rechargeable battery, up to one hour of use Ideal for road testing and mobile use Measures exhaust emissions for CO, CO2, HC, O2, NOx and AFR/Lambda Provides an instant assessment of an engine vehicle exhaust and catalytic converter MODIS, VERDICT® and VERUS® Link for enhanced real-time viewing Setup required with included software on USB stick Gather all the evidence required for effective and accurate vehicle diagnostics on one screen in real time View, graph, save and recall data Monitor and reduce vehicle emissions, improve driveability and fuel efficiency There are 255 memory locations in the analyzer to track and print data for the same or many different vehicles Compatible with gasoline, CNG, propane and diesel fuel types Annual calibration and sensor replacement performed at Crystal Lake Northern Repiar enter Meets required industry standard
-
Product
VOC Monitoring System
EXPEC-2000
-
EXPEC-2000 VOC system is based on the principle of gas chromatography technology(GC-FID),it is of capable monitoring characteristic factors such as methane/non-methane hydrocarbons and benzene etc.
-
Product
Motor Exhaust Gas Analyzer
MEXA-1300R
-
MEXA-1300R is a motor exhaust gas analyzing system for two and four stroke engine assembly lines and has an integrated sample handling system for removal of oil and moisture. The measurement of CO, CO2, HC and O2 (optional) in exhaust gases is made simply by inserting the sample probe into the tail pipe. AFR and Lambda are also calculated from the exhaust gas concentrations.
-
Product
Green House Gas Analysis
-
Gas chromatographs help analyze green house gases in air and soil. In addition to nitrous oxide, which is known by its high global warming potential, CO and CH4 are measured by a single analysis.
-
Product
Controllers & Alarms
-
Teledyne Gas & Flame Detection
Equip yourself with high-performance gas detection systems thanks to Teledyne Gas and Flame Detection! Our selection offers several ranges of units and alarms compatible with your gas detectors.
-
Product
Low Pressure Drop Thermal Mass Flow Meter
HFM-200 LFE
-
The HFM-200 LFE Series by Teledyne Hastings can be configured and accurately measure gas flow in a broad array of applications. Featuring reliability and stability, the 200 Series is chosen by users for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow meter compatible with most gases.The HFM-200 LFE meter has flow ranges from 0-10 sccm to flows of 0-15,000 slm; provides analog outputs, and is constructed of stainless steel. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Cleaning for oxygen service is available. Our laminar flow elements (smooth, threaded or flanged) are available in various sizes from 3/8" up to 8". Low pressure drops at full scale flow.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Digital "A" Flow Controller for Low Flow
HFM-D-300A / HFC-D-302A
-
HFM-D-300A / HFC-D-302A mass flow instruments have flow ranges from 0-5 sccm to 0-25 slm; use all metal seals, provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
Product
In-Situ Cross- Stack Laser Analyzer
-
LS25 is an in-situ analyzer for non-contact measurement of the concentration of gases. The measuring principle of the LS25 is based on the principle of single line spectroscopy (Tunable diode laser absorption spectroscopy, TDLAS). A single cross-sensitivity-free absorption line of the gas to be measured is selected in the near infrared range. A single-mode diode laser operating at room temperature scans the respective absorption line. By using an opposite receiver, the absorption caused by the sample gas is measured and from this the concentration is calculated. An automatic correction for pressure and temperature changes is possible. In addition, the transmission is displayed respectively output as a signal for preventive maintenance.
-
Product
Air Pollution Multigas Calibrator
APMC-370
-
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
Product
Chilled Mirror Transmitter
DewTrak II
-
The DewTrak II uses the chilled mirror dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a platinum resistance thermometer to accurately measure that temperature. Outputs include 4 to 20mA, 0 to 5 Vdc, or 0-10Vdc and an RS232 serial port as well as electrically isolated relay contacts.
-
Product
Portable Sulphuric Acid Dewpoint Temperature Monitor
-
The fuels used in boilers, such as coal, heavy oil and natural gas, contains S. during the combustion process, S and O₂ form SO₂, and a small amount of SO₂ is converted into SO₃ under catalysis of Fe₂O₃, V₂O₅ and other catalysts. Under normal circumstances, the volume of SO₃ in the boiler flue gas is 1×10-6~50×10-6, and the water vapor is about 10%. When the temperature of the flue gas is below 200°C, SO₃ and the water vapor are completely combined into H₂SO₄ vapor. A small amount of H₂SO4 vapor will significantly increases the acid dew point. When the surface temperature of the boiler heat exchange equipment is lower than the flue gas acid dew point, the H₂SO₄ vapor will condense on the surface to become sulfuric acid solution with a concentration of about 80%, which will adhere to the surface of the heat exchanger and cause acid corrosion. Typical equipment that is prone to corrosion includes air preheaters, induced draft fans and flue walls.
-
Product
Airborne Ultrasound Sensors
-
Find compressed air, gas and vacuum leaks in noisy environments. Increase your inspections distance and reach hard to access areas.
-
Product
Domestic And Light Commercial
-
Features advanced flue gas analysers designed for installing, commissioning, and servicing gas, oil, and biomass appliances.
-
Product
GC Driver For OpenLAB CDS
-
Shimadzu Nexis GC-2030 gas chromatographs can now be controlled from Agilent OpenLAB CDS (chromatography data system). The Nexis GC-2030, which provides the world's highest level of performance and user-friendly interface, can now be used in an OpenLAB CDS environment.
-
Product
24" Rackmount Drawer, Unshielded, 10.5"H x 20"D
DR-102420
-
Unshielded drawers are constructed of 20 ga. CRS and are furnished with ball bearing chassis slides to provide smooth operation. Available for 19" and 24" rackmount in 20", 24" and 30" depths, with or without a keylock
-
Product
Gas Analysis
HPR-90
-
The HPR-90 automated package cracking analysis system is a complete system optimized to analyse gas within sealed volumes such as light bulbs.





























