Pressure Calibrators
Provide precision simulation of known values to ascertain pressure instrument graduation deviation.
-
product
Calibration
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
product
Frazier Differential Pressure Air Permeability Tester
The Low Pressure Air Permeability Machine was developed by the National Institute of Standards and Technology of measuring the air permeability of textile type materials. and It is the acknowledged standard of the U.S. Government and the U.S. Textile Industry. The second model, High Pressure Air Permeability Machine is produced on the same principle as the Low Pressure Machine, but designed with a much greater versatility for use through its higher attainable airflow and differential pressure. Both models are extremely accurate and reliable, very easy to operate, and nearly maintenance free.
-
product
MEMS Pressure Test
Cohu‘s well established pressure test equipment are providing high volume final test solutions for all pressure sensor markets.
-
product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
product
Seismic Transducers Calibration System
Calibration of the seismic sensors should be conducted in the low-frequency domain, which means, that the relative method used for calibration of the vibration transducers is not applicable since it does not guarantee the required accuracy level. The problem is that the reference accelerometers have uneven AFR characteristic in the low-frequency domain. Thus, calibration of seismic transducers requires implementation of a different approach.
-
product
Digital Pressure Meter
ZET 7012-A-VER.3
Digital pressure meter ZET 7012-A-VER.3 is used for fast and simple absolute pressure measurements and measured values data transfer in digital format via RS-485 or 4-20 mA interface.
-
product
Calibration Kits
Atec’s Portable Calibration Kit, PN AHT63506-1, is used to calibrate instrumentation and transducers in engine test cells, as required per T.O. 33K6-4-3416-1 or Atec Technical Manuals.
-
product
Calibration Services
Koehler Instrument Company, Inc.
Koehler offers a growing variety of ISO 17025 certified petroleum testing materials for your calibration and test method validation requirements. Our Technical Service Department provides calibration services conducted with traceable reference materials and standards.
-
product
General Purpose Pressure Transducer and Transmitter
P55
The robust P55 pressure transducer provides cost-effective reliability for severe test environments. With extreme resistance to shock and vibration, the P55 pressure transducer delivers the same high-level performance expected from more delicate differential pressure transducers and pressure transmitters. With variable reluctance sensing technology, the P55 pressure transducer delivers fast dynamic response, high resistance to vibration and superior signal stability through ambient temperature change for a wide variety of low-pressure to high-pressure measurements. The P55 pressure transducer will accept both liquids and gases directly at the sensing diaphragm and there are no internal isolation fluids to slow the sensor response or cause excessive temperature drift errors.
-
product
Condec Pressure Instrumentation
The Condec brand has stood the test of time with popular and dependable models of pressure instrumentation that continue to be in high demand.
-
product
Differential Pressure Instruments
The testo 512 differential pressure meter is available as four models. This model has a measuring range from 0.0.29 psi and is ideal for measuring pressure differences at filters and for carrying out pitot static tube measurements in air ducts at air flow speeds between 16 and 180 fps.
-
product
Pressure Sensor
Futek Advanced Sensor Technology, Inc.
Pressure Sensors manufactured in US by FUTEK Advanced Sensor Technology (AST), one of a handful of companies producing high quality pressure sensors, using metal foil strain gauge technology. Metal foil Strain-gauge technology is one of the most common types of pressure sensors in the market and is also commonly known as pressure transducers.
-
product
Sound Velocity, Temperature and Pressure for Underwater Vehicles.
UV-SVP
Designed for Underwater Vehicles where space is at a premium, the UV-SVP is based on the Valeport miniSVS. Incorporating Valeport’s class-leading time of flight sound speed sensor, a PRT temperature sensor and a 0.01% pressure sensor in a compact package weighing just 750 grams (in air), the lightweight titanium housing gives a depth rating of 3000m. A wide range (9-30V DC) isolated power supply and RS232 communications complete the package.
-
product
High-Performance Multifunction Calibrator
5730A
The new 50 MHz wideband option for the 5730A High-Performance Multifunction Calibrator provides expanded wideband capabilities to self-maintaining laboratories by providing a method to calibrate the 50 MHz input of the 5790B AC Meaasurement Standard. This is accomplished by characterizing the 5730A's 50 MHz output using a precision thermal voltage converter (TVC), thus reducing uncertainties to calibrate the 5790B.
-
product
Pressure
ACI’s wet- and dry-media pressure sensors ensure your building operates at the highest level of efficiency. Multiple models have user-configurable options to maximize application flexibility.
-
product
Pressure Transducers & Transmitters
NOSHOK is an industry leader providing highly reliable and repeatable industrial pressure transducers and transmitters. Multiple measuring ranges, output options, process connections and electrical connections are available. NOSHOK Industrial transducers and transmitters are ideal for applications such as HVAC, hydraulics and pneumatics, injection molding machines, railroad equipment and stamping & forming presses, power generation, and aerospace equipment.
-
product
Vertical Entry Liquid Level Pressure Sensor
LL-V
Honeywell Industrial Automation
The rugged Model LL-V vertical entry submersible liquid level sensor from Honeywell Sensotec can be suspended in an open tank or attached to the crown of an enclosed tank and used to any depth. The atmospherically vented oceanographic cable assembly exits through a 1/2-14 NPT threaded conduit connection that allows mechanical or chemical protection tubing or pipe to be threaded on over the cable.
-
product
HVAC Pressure Transmitter
DP850/851
The DP850/851 transmitters are designed for low pressure measurement in HVAC applications. The DP850 is available in full scale pressure ranges as low as 0.25 inH2O and the DP851 can be ranged to 0.025 inH2O full scale. Both models are available in 4-20 mA or 0 to +5 Vdc signal output options.
-
product
RF Calibration Accessories
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
product
Reid Vapor Pressure Analyzers
Increase your gasoline blending profits with process Reid Vapor Pressure measurements and automatic air saturation of the sample.
-
product
Pressure Sensors
*Sensors and transmitters with integrated evaluation*Specially for the use in hygienic applications*Excellent overload protection and long-term stability*Measuring ranges of -1…600 bar*Variety of process connections available
-
product
Vacuum Pressure Sensors
MKS, Granville-Phillips® Vacuum Gauges & Sensors cover a broad spectrum of vacuum measurement solutions.
-
product
mA Loop Calibrators
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
Portable, self-contained, high-intensity acoustic microphone calibration source
-
product
Precision Underwater Pressure Sensor
miniIPS
The miniIPS is a precision underwater pressure sensor; 0.01% accuracy, a titanium housing and a choice of pressure ranges make it a cost-effective solution for offshore engineers, vehicle pilots and other operators who require highly accurate depth information in real-time.
-
product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
product
Lamp-Based Calibration Light Sources
Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.
-
product
Differential Pressure Transmitter
608
The Dwyer Series 608 Differential Pressure Transmitters convert positive, negative (vacuum), or differential pressures of clean, dry air or other non-conductive, non-corrosive gases into a standard two wire, 4-20 mA output signal
-
product
Decade Box, Calibrated W/D & U, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL DU
The 72-7265 CAL DU from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Reference Temperature Calibrator
JOFRA™ RTC-187
AMETEK Sensors, Test & Calibration
RTC-187 provides high-quality temperature measurement from -45 to 180°C. The 180°C is a 25° expansion over the range of the RTC-157, and it’s now the hottest temperature available for a calibrator that also supplies cold temperatures.