- Pickering Interfaces Inc.
product
Standard Voltage 50 Pin D-Type Cables - Connector to Connector
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
Multi-Channel Phase Comparator
VCH-315M
Multi-channel phase comparator VCH-315M, together with a computer and special software, is designed for simultaneous measurement of frequency instability characteristics (RMS, RMS) of a group of sinusoidal signals of standard frequencies 5; ten; 100 MHz.
-
product
Single Phase Reference Standard Meter
Signals & Systems India Private Limited
The Single Phase Portable Reference Standard (SPRS-1102) from SANDS is a portable meter test equipment that helps to calibrate the error present in the single-phase energy meter i.e. the meter under test (MUT). The SPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, phase angle etc of the meter under test. It has an LCD display and an alphanumeric keypad to suit the user. It can be interfaced with the PC for analysis. It has the capability of storing 1000 test results.
-
product
Network Analyzer
DPNA-6G AXIe
The AXI DPNA-6G module is the world's first network analyzer in the form factor of the AXIe-1 module, as well as the first Russian device that meets the AXIe-1 standard. In the mode of the network parameters meter, the AXI DPNA-6G module measures the vector values of the network parameters on two ports: transmission coefficients (S12, S21) and reflection (S11, S22). At the same time, all necessary types of calibrations are supported: one- and two-port short-circuit, XX, matched load, transmission normalization. The software supports the import of third party calibration standard parameters. In the measuring receiver mode, the module provides:*generation of a harmonic signal (frequency synthesizer);*spectrum analyzer and power level in a given band;*measuring the frequency of a known signal;*measurement of analog modulation parameters;*phase noise measurement.
-
product
SUC-C Series Microwave Upconverter
SUC-C
SUC-C Series Microwave Upconverter is a broadband frequency converter that is dedicated for satellite communication. It has a high performance, high reliability and an octave covered by RF signal. Its frequency step is precise and accurate to 1Hz with a variety of IF and signal bandwidth choices. SUC-C series is equipped with functions like self-testing and combination alarm which is suitable for long-time uninterrupted use, guaranteed safety and reliability.SUC-C series microwave upconverter is mainly designed for satellite communication system, signal monitoring system, and electronic countermeasure system with an excellent phase noise, clutter suppression, and in-band flatness data. It is able to provide a transparent RF transmission channel to all videos or data communications. All programming commands can be set through a local panel or through network remotely. SUC-C series microwave upconverter has a standard 2U size.Applications: T&M Systems / Satellite Communications / MIMO
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
Circuit Breaker Analyzers & Timers
CAT Standard Series
Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.
-
product
MTB Calibration Adapter
2450-CAL-30
The MTB Calibration Adapter (Catalog No. 2450-CAL-30)is a socket adapter that’s designed to bring phase A, B, and C current and potentials of a TESCO Multi-Position Test Board to an external RD-30 reference standard for calibration of the Test Board.
-
product
Linear regulated power supply with thyristor pre-regulation
NTN
High efficiency Short circuit proof and unlimited operation with full current in short circuit condition voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked 4 digit DVM for voltage and current (for table-top models) Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals Parallel and series connection possible Suitable for inductive and capacitive loads for 700 W nominal power and higher, limitation of inrush current on switching on Interlock loop to monitor the external load and internal loop as a standard for three phase units Elapsed-hour meter as a standard for three phase units
-
product
Three Phase Power Analyzer
930A
Model 930A Three Phase Power Analyzer is an economical alternative to the Model 931A Power System Analyzer when the dc voltage measurement, transducer calibration and timer features are not required. The Model 930A has the same ac accuracy as the Model 931A with PowerDSA™ Digital Signal Analysis. Basic accuracy of 0.05 % of reading and 0.05 ° phase, harmonic analysis, and full three-phase capability are standard.
-
product
PXIe-5841, 6 GHz, 1 GHz Bandwidth, RF PXI Vector Signal Transceiver
786982-01
6 GHz, 1 GHz Bandwidth, RF PXI Vector Signal Transceiver - The PXIe-5841 is a vector signal transceiver (VST) with 1 GHz of instantaneous bandwidth. It combines vector signal generator, vector signal analyzer and high-speed serial interface capabilities with FPGA-based real-time signal processing and control. The PXIe-5841 features the flexibility of a software defined radio architecture with RF instrument class performance. This VST delivers the fast measurement speed and small form factor of a production test box with the flexibility and high performance of R&D-grade box instruments. The PXIe-5841 is available with an optional high-performance local oscillator module for improved phase noise, measurement time, and EVM performance. You can use the VST to test a variety of cellular and wireless standards such as Wi-Fi 6 and 5G NR. In addition, you can expand the small, two slot 2U PXI Express form factor to support multiple input, multiple output (MIMO) configurations.
-
product
CCFL Ballast Tester
WT2000A-CCFL
This tester is specially designed for analyzing the electrical characteristics of CCFL Electronic Ballast, meets the test requirements in international standard• Input characteristics analysis: measure Vrms, Irms, W, PF, Hz, phase angle Measure THD, 0 to 39th harmonic components, Accuracy: ±(0.4% reading+0.1% range+1 digit)• Output characteristics analysis: measure lamp voltage, lamp current, lamp power, oscillatory frequency, crest factor of lamp current, Accuracy: Class 2• Interface RS-232C provided for easier communication with PC for printing test report
-
product
Synthesizers
A low phase noise frequency synthesizer module designed and manufactured for standard test instrumentation, communication, and Radar systems as a local oscillator.
-
product
Electrodes
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
product
EMC Testing
Does your product send or receive electromagnetic data? This can be analyzed using various tests. We investigate the interference immunity and emitted interference of simple electrical devices and complex machinery. Our EMC measurements and tests conducted in accordance with standards recognize all activity in the electromagnetic field and ascertain how immune to interference a piece of equipment is. We will also offer guidance on optimizing the product in terms of its EMC properties during the development phase.
-
product
Environmental Chamber
REXMED REC-280
MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
product
TEST BOX
6280 TB
Standard Electric Works Co., Ltd
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1
-
product
Programmable AC Power Source
LMX Series
The LMX Series encompasses an all new collection of High Performance 1 phase and 3 phase Linear AC Power Sources. All standard models operate from 15 to 5,000 Hz, range in power from 500VA to 30kVA, and provide nominal output voltage ranges up to 600Vrms L-N.
-
product
High Precision Motorized Rotation Stages
RAK
Model: RAK High Precision Motorized Rotation Stages New construction ,new technology;the key index has up to the international level of the similar products by strictly inspection .This series products are used to laser precision processing,three dimensional scanning measurment system and so on . ◆Stepper motor drive ,finish angle adjustment automatically; ◆Worm and worm wheel has adopted durable to friction material ,high reliable accuracy of rotation . ◆High precision ,ultra steel axises of importing ,achieve high precision, high load stable motion ◆Outer circle has scale, interface , convenience for signal’s output ◆Circle grating and encoder combine with MC series controller ,achieve closed-loop control Standard stepper motor and DB9 interface, choose to controller flexibility ◆three phase stepper motor and servo-motor is planning
-
product
Fiber Optic Modem
VCH-608
The VCH-608 fiber optic modem is designed to receive and transmit via a fiber optic communication line (FOCL) signals of frequency and time standards (TSV) :- pulse signals 1 Hz (1 PPS) with delay compensation,- harmonic electrical signals with a nominal value frequency 100 MHz with phase instability compensation.
-
product
NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783106-01
400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.
-
product
Comb Generator, 10 MHz to 26.5 GHz
U9391C
The Keysight Technologies, Inc. U9391C comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
product
903 Benchtop Three Phase 40A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Multifunctional Meter
AEM-DRA
Chuan Sheng Electronics Co., Ltd.
The AEM-DRA series has 2 independent and isolated main circuit inputs , can use for different power system.Up to 24 single phase or 8 three-phase circuits, programmable from push buttons with LCM display panel, or using Adtek program software through RS485 communication port.Hardware standard built in a RS485 Modbus communication port , 2 Digital inputs, 4 Relay outputs, LCM and 2 MB flash for data-logging.Optional second communication port for Ethernet, ProfiBus ,LonWorks ,BACnet and Zigbee solutions.Din rail mounting , compact and easy installation, programming through computer and push buttons easy to use.
-
product
Electricity Meter Test Equipment
The Reference Standard RS is precision standard meter in single- and three-phase version for electrical power and energy measurement. It is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any true or artificial mode of operation in three phase system and is capable to evaluate individual quantities in any phase
-
product
Energy Analyzer
EP600i
The EnergyPro EP600i is portable and easy to use. Perfect for single phase or three phase energy consumption analysis and basic power quality monitoring. It supports standard wiring configurations and comes with a set of 1A - 2500A WideRangeFlexCT ™. The graphics display makes setup very easy and intuitive - you can setup and record data without looking at the manual!
-
product
8-Channel, 10 MHz Precision ReferenceWith Sine and Logic Outputs
ITS-6200
The ITS-6200 is a versatile 10 MHz laboratory frequency reference useful for synchronizing test instruments to a common standard. Eight outputs are provided, each which can be configured independently as sinewave or logic level square-wave signals. Additionally, CMOS logic levels can be set for 5V, 3.3V, or 2.5V logic family compatibility. A 10 MHz reference input is provided to phase lock the ITS-6200 to an external reference, such as a GPS or Rubidium standard, or cascade multiple ITS-6200 units for additional outputs. The low phase noise and high stability OCXO within the ITS-6200 is suitable for the most demanding applications, whether free-running or phase locked. The compact size and low power consumption makes the instrument highly portable and suitable for AC-powered operation in the lab or battery operation in mobile or field applications.
-
product
Multifunction Electrical Installations Meter
MPI-520S
The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.
-
product
Solar Analyzers
Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power
-
product
Enlarge Environmental Chamber
REXMED REC-480
MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc