Filter Results By:
Products
Applications
Manufacturers
-
product
Circuit Breaker Operational Analyzer
CBScan
CBScan is a compact and portable circuit breaker analyzer. It has limited number of channels as compared to AutoScan, but is ideal for basic shop-floor and on-site testing requirements. This analyzer has complete functionality of AutoScan. However, to ensure portability, an external laptop is required to run the test software.
-
product
Circuit Breaker Finders
Is a small battery-operated electronic tool with two parts—a transmitter and receiver. It is designed for single purpose—to identify which circuit breaker in a main service panel serves a particular outlet or light fixture to which the tool's transmitter is connected.
-
product
6 Contacts- Circuit Breaker Analyzer
CB14
The CB14 is a 6 contacts circuit breaker analyzer designed to perform Timing, Motion as well as Static & Dynamic Resistance Measurement (DRM) in a single test. It also includes 3 multifunction analog inputs.
-
product
Circuit Breaker Test System
TDR900
It operates and records a circuit breaker’s contact timing, motion, velocity, main contact engagement & synchronization, trip and close coil initiation and currents.
-
product
Circuit Breaker Testing Equipment (SCOT Series)
SCOT M3K+
SCOT M3K+ measures and displays CLOSE, OPEN and CLOSE-OPEN times of Main contacts of 3 poles connected end to end, simultaneously. Ideally suitable for CBs with single break per pole.
-
product
Earth Leakage Circuit Breakers
Mitsubishi Electric Automation, Inc
Like molded case circuit breakers, these circuit breakers are utilized to open/close low-voltage circuits and protect wiring by automatically closing circuits when they''re overloaded or if a short-circuit occurs. We offer a comprehensive range of circuit breakers that provide superior performance in electrical protection, isolation and power distribution applications. Our circuit breaker products comply with various standards such as JIS, IEC, EN, GB and UL/CSA, and with easy to install accesories, the Mitsubishi Electric circuit breakers are "user-friendly" and ensure the best solution for virtually every application.
-
product
High Voltage Pultruded Resin Bond Glass Fiber Rod
This Test Set-Up can be used to test any kind of Drive Insulator used in Circuit Breaker.
-
product
6 Contacts- Circuit Breaker Analyzer
CB14
The CB14 is a 6 contacts circuit breaker analyzer designed to perform Timing, Motion as well as Static & Dynamic Resistance Measurement (DRM) in a single test. It also includes 3 multifunction analog inputs.
-
product
SF6 Optical Gas Imaging Camera
FLIR GF306
The FLIR GF306 optical gas imaging camera visualizes sulfur hexafluoride (SF6) and other gas emissions without the need to shut down operations. SF6 is used in the electric power industry as an insulator and quenching medium for gas-insulated substations and circuit breakers. The portable, non-contact GF306 allows you to quickly scan substations for leaks while maintaining a safe distance from high-voltage equipment. By catching leaks early, the GF306 reduces lost revenue to breakdowns and repairs.
-
product
Power Factor RLC Load
3282(280V,1875W / 3700VA )
3282 power Factor RLC Load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and Vmin. In addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
-
product
Circuit Breaker Testing
ACTAS
Portable and stationary test systems for performing fully automatic function tests on all types of switchgear devices, including the drive units of switch bays. ACTAS test systems provide precise information as to the condition of the chamber and drive unit without requiring them to be opened. The sheer number of parameters to be determined, the wide variety of different types of switchgear equipment in use and the harsh environmental conditions encountered during on-site tests place extreme demands on test equipment.
-
product
Circuit Breaker Test Systems
Crest has over a decade of experience of designing and manufacturing test systems for testing all the different kinds of switchgear and controlgear.
-
product
Primary Current Injection Test Sets
Our primary current injection test sets cover from 750A through to 6000A. Available in single phase, testing applications include testing and timing of under and over current relays, circuit breakers and CT ratio testing.
-
product
3 Wire (Analogue) Earth Resistance Tester
4105 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
product
Locomotive Circuit Breaker Analyser
CBScan Locomotive Circuit Breaker
CBScan Locomotive Circuit Breaker Analyser is a compact and portable analyser used for testing 25 kV medium voltage circuit breakers that are used in electric locomotives for protection from the frequently occurring short-circuits in the overhead catenary system. The analyser is ideal for railway yards for performing periodic maintenance checks.
-
product
HV High Performance Circuit Breaker Analyzer
CBV-32
We conceived the CBV-32 to provide the best range of testing for electrical facilities such as circuit breakers (using gaz, oil, air, vacuum…) or synchronous condensers all the way up to 800kV and more. It combines Timing, Motion Dynamic Resistance Measurements, and Vibration, all in a single test.
-
product
Fault Trapper
#TFT100
Stop guessing about circuit breaker tripping issues. See why, when and where a circuit breaker trips. For the first time, you can detect the type of fault, and locate the position of an electrical “event” that causes intermittent and persistent circuit breaker trips, and No Fault Found (NFF) conditions. The critical information needed to reduce […]
-
product
Primary Injection Test Set
PI-6000
The PI-6000 is a rugged & durable primary injection test set capable of testing circuit breakers up to 6,000 amperes frame size. It incorporates an output transformer with dual primaries to facilitate its use on power sources of 480 VAC as well as 208-240 VAC. The unit also includes dual secondaries to provide optimal impedance matching to a wide range of circuit breaker sizes. An internal voltage sensor automatically configures the AC control power section to be energized only when properly configured for the applied voltage.
-
product
Circuit Breaker Analyzers & Timers
CAT Standard Series
Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.
-
product
Fault Locators
For the first time, you can detect the type of fault and locate the position of an electrical fault that causes intermittent or persistent circuit breaker trips, thus giving you the critical information needed to reduce call backs for circuit breaker trips.
-
product
Programmable DC Power Supply
CBCT
The CBCT is a variable voltage DC power supply designed specifically to test substation circuit-breaker Open and Close coils. The CBCT uses the substation’s DC power supply to electronically generate a programmable output voltage from 5% to 95% of the source voltage. The CBCT can maintain up to an 80A test current while maintaining 2% or better voltage regulation during the circuit breaker coil operation.
-
product
Multiple-Bus Architecture Cable/Harness Test System
CKT1175-MBA
The CKT1175-MBA (for multiple-bus architecture) will provide seamless testing of electronic racks, panels and chassis containing passive and active components such as relays, solenoids, switches, circuit breakers, lamps and LED's, diodes, resistors, capacitors, etc. This functionality is made possible by a switching matrix that is up to 10 levels deep, plus a multiplexer that controls the various stimuli sources, instrumentation connections, and external energization outputs.
-
product
Oil Test Set
7000
Cambridge Instruments & Engineering Co.
Ideal for speedy and accurate testing of Breakdown / withstand test of transformer and circuit breaker oil, in accordancewith IS 6792 : 1992 for oil testing.
-
product
Circuit Breaker Analyzer
CAT Standard Series
The CAT Standard series circuit breaker analyzers & timers are stand-alone or a PC-controlled digital instruments for circuit breakers condition assessments. The timing channels record closing and opening of the arcing, resistor, and auxiliary contacts. CAT Standard series records graphs of both, trip and close coil currents and displacements of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the pre-insertion resistors (if present in the circuit breaker). Test results can be downloaded to a USB memory stick or saved to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Test results can also be printed on the 80 mm (3.15 inch) thermal printer (optional accessory) in tabular and graphical form. CAT Standard series provides an easy selection of different operational modes:
-
product
Primary Current Injection Sets
Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.
-
product
Digital Circuit Breaker Analyzer
CT-7000 S3
The CT-7000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-7000 S3 is available with 3 (part number 9021-UC) or 6 contact timing channels (part number 9100-UC). The CT-7000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Both contact and motion analysis can be performed on all circuit breaker operations (OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, and OPEN CLOSE-OPEN). The CT-7000 S3’s timing window is selectable between 1 second, 10 seconds, and 20 seconds.
-
product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
product
Stationary Circuit Breaker Test System
ACTAS C160
Stationary test system for carrying out fully automatic final factory tests, type and function tests on all kinds of switchgear devices, such as circuit breakers, disconnectors or earthing switches, regardless of the type of drive unit. All the electrical and mechanical parameters needed for the assessment of switching performance are measured in real time and evaluated without either the main contact chambers or the drive unit having to be opened. The system has analog and incremental input channels for the acquisition of analog quantities.
-
product
Automatic Relay Tester
The protective devices such as relays, overload coils, circuit breakers must be checked regularly to ensure that, they are always ready to operate correctly. If a fault occurs in the equipment, which they are protecting, routine relay testing will quickly detect the faulty, incorrectly adjusted protection circuits correctly. It is usually necessary to measure its operating time. The micro controller based time interval meter is used for this purpose in all AJIT brand relay testers.