IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- support@dv-power.com
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
-
Product
Battery Extra Load Units
-
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
Product
Transformer Test Equipment
-
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
Product
Micro-Ohmmeters
RMO-G Series
-
The RMO-G is a portable micro-ohmmeter designed for contact resistance measurement of non-inductive test objects and applications with increased safety requirement. It tests medium and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. Due to its Both Sides Grounded and Remote Control functionalities, the instrument accurately measures even in the most demanding environments, providing additional safety to testing personnel.The RMO800G is the most powerful portable micro-ohmmeter on the market with 800 A output current. RMO200G is our best seller in the USA. A user can choose the appropriate model depending on the output current requirement, from 100 A (RMO100G) to 800 A (RMO800G).We use an unbreakable plastic case with IP67 protective rating (with closed lid) for instruments’ housing. Although very portable and lightweight, RMO-G micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents. Consequently, it enables the usage of thinner/longer test cables. RMO-G generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. During the testing, it increases current before measuring and decreases current after the measurement. This significantly decreases magnetic transients and ensures great accuracy.Special current clamps measure a current through groundings when the instrument tests in Both Sides Grounded conditions. The instrument itself powers these clamps. If even higher safety level is required, the Remote Control feature enables the operator to perform measurements from distant locations.RMO-G instruments can store up to 500 measurements in internal memory. Also, they have a built-in thermal printer and USB flash drive available as an option. An additional option is the built-in High Precision module suitable for measurement of very low resistance, in the range from 1 to 30 µΩ, with 0,01 µΩ resolution.Our free DV Win software communicates with the RMO-G micro-ohmmeters via USB or RS232 interface. It allows a user to run the test remotely from a PC. Also, a user can download test results, analyze and generate fully configurable test reports through the software.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
Transformer Turns Ratio Testers
-
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Coil Analyzers
SAT Series
-
The Coil Analyzers SAT30A and SAT40A are powerful, lightweight units ideal for testing of circuit breakers. Substation battery is not connected or available. The SAT series instruments are intended to supply circuit breaker coils and spring charging motors. They spring charging motors (SAT40A – AC and DC) as a part of commissioning and maintenance testing.
-
Product
Battery Chargers
BAC Series
-
Battery charger BAC series is a portable and universal battery charging solution. It is primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300V DC level. However, the unit can charge the string of any battery type by one of the available charge modes:IU (constant current + constant voltage)UU (constant voltage + constant voltage with a current limit)Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge.Variety of implemented protections, such as thermal, overcurrent, undervoltage, and overvoltage, assure the charging process will be safe for the battery and the instrument itself.A user doesn’t have to switch off the main charger in order to use BAC series charger. Just the opposite, the BAC series charger should support the main charger to speed up the process. An alternative use is to quickly recharge a battery following a discharge test.The provided display enables users to monitor all relevant information during the charging process and to adjust charging parameters and limits in real-time.The instrument offers the best power-to-weight ratio in the market, weighing only 10 kg / 22 lbs with the maximum output power of 2,7 kW.The maximum charging currents for lead-acid, Ni-Cd and Li-ion batteries, at various battery voltages, are presented in the brochure.
-
Product
Circuit Breaker Analyzers & Timers
CAT Standard Series
-
Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.
-
Product
Motor/Generator Test Equipment
-
Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment include:Winding resistance measurement of generators and electrical motorsResistance measurement of high-current bus bar jointsResistance measurement of cable splicesAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, a DV-Win software generates a test report a single click. Finally, a user can easily customize the report and save it in different formats, such as XLS and PDF.
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
Product
Coil Testers & Power Supplies
POB Series
-
Coil testers and power supply units, models POB30 and POB40 are ideal for commissioning and maintenance testing of circuit breakers. The station supply is not available. The POB series are power supply units implementing the latest power electronics technology. They are developed for use in switchyards, power and industrial environment. In addition to providing current and voltage for breaker testing, they can measure certain coil parameters.
-
Product
Motor Winding Ohmmeter
RMO-M Series
-
The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement
-
Product
Circuit Breaker Analyzers & Timers
-
CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.
-
Product
Tap Changer Analyzers & Winding Ohmmeters
-
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints















