Product
Calibrator for Vibration Transducers
HD2060
-
Hand-held calibrator for vibration chains with frequency 15.915 Hz and levels 1 m/s² and 0.1 g, and frequency 159.155 Hz and levels 10 m/s² and 1 g. With LCD display.
-
Product
NI-9421, 24 V, 8-Channel (Sinking Input), 100 µs C Series Digital Module
NI-9421 / 779002-01
Digital Module
24 V, 8-Channel (Sinking Input), 100 µs C Series Digital Module - The NI‑9421 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels and has an LED indicating the state of that channel. The NI‑9421 offers isolation between the input channels and earth ground.
-
Product
Portable or Stationary Ultrasonic Flowmeter for Liquids
DUC
-
Two ultrasonic clamp-on transducers are externally mounted on a pipe and produce an acoustic path. The transducers send and receive acoustic signals and their transit times are measured by an electronic flow transmitter. The signal is accelerated by the flow in the forward direction. The return signal is decelerated by the flow in the opposite direction. The difference in time between the two, together with the path length L, can be used to determine the average flow velocity. This principle is known as the acoustic time-of-flight principle.
-
Product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2A
-
The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
Product
High Accuracy AC Reference Source
515
-
Clarke-Hess Communications Research
The Model 515 High Accuracy AC Reference Generator fills a need for a relatively low cost and practical solution for supplying a reference excitation to typical LVDT and Synchro/Resolver transducers. The Model 515 has built-in load sensing which, in effect, yields "zero" output impedance and virtually eliminates the effects of fluctuating output loads. With up to 15 VA of output into loads with as much as 80 of phase shift, the Model 515 is ideally suited to driving inductive loads.
-
Product
8/16-CH 16-Bit Analog Output Cards
PCI-6208/6216 Series
Analog Output Module
ADLINK PCI-6208/6216 series are 8 or 16-CH, 16-bit, analog output cards. The PCI-6208V-GL offers 8 voltage outputs with ±10 V range, featuring 15-bit monotonicity and 10 V/μs slew rate. The on-board analog switches minimize the power-on glitches. PCI-6216V expands the voltage output channels to a total of 16 for higher analog output density requirements. In addition to the voltage output functions, the PCI-6208A features 8 current outputs with ranges of 0-20 mA, 4-20 mA, and 5-25 mA. The daughter board EXP-8A provides high-quality voltage to current transducers. The PCI-6208A device is capable of delivering 14-bit monotonicity with 1.3 mA/μs slew rate. ADLINK PCI-6208 series devices provide high-resolution, high-density analog output functionalities and are suitable for ATE, signal generation, industrial process control, servo control and other industrial control applications.
-
Product
6 Channel Signal Conditioner & Data Acquisition Module
DP-cPCI-1197
-
DP-cPCI-1197 is a high-resolution signal-conditioning module that amplifies the signals from full-bridge based transducers. This signal-conditioning module is available on a cPCI module form factor. This module has four gain settings to accommodate a wide variety of sensor output voltages. In addition, this module has an adjustable excitation voltage to accommodate transducer excitation requirements.A high resolution sigma-delta ADC and variable gain amplifier forms the core of the signal conditioning system. Direct digital conversion and digital isolation ensures a better signal integrity in comparison with the conventional analog system.
-
Product
Load Washer
5000 Series
-
The Load cell is a stainless steel sub-miniature strain gage based transducer with compensated temperature performance. This type provides measurements up to 20000 lbf with better than ±0.5% (full scale) non-linearity
-
Product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2
-
The TMO-2 Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The units provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Full scale output is specified at plus or minus 10 VDC. The TMO-2 provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability for applications such as weighing scales. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
Product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
-
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
Product
Force Sensors
-
HBK Force Sensors and Force Transducers with strain gauge or piezo technology measure static and dynamic tensile and compressive loads up to 20 MN - with virtually no displacement.
-
Product
Extensometers for Indirect Tensile Testing of Asphalt
Model 3911
-
Jinan Testing Equipment IE Corporation
For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
NI-9472, 24 V, 8-Channel (Sourcing Output), 100 µs C Series Digital Module
779004-01
Digital Module
24 V, 8-Channel (Sourcing Output), 100 µs C Series Digital Module - The NI‑9472 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 30 V, … features transient overvoltage protection between the output channels and the backplane, and has an LED that indicates the status.
-
Product
LED Power Driver ATS
8491
-
1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series
-
Product
Ultrasonic Clamp-On Flow Sensor
SEMIFLOW CO.65
-
SEMIFLOW CO.65 non-contact clamp-on flow sensors are ideal to measure abrasive, adherent, corrosive, and ultra-pure liquids on rigid plastic tubes and pipes used in the semiconductor industry. Equipped with an integrated electronic unit, they function as a complete flow meter in the size of a small transducer without an external board or transmitter.
-
Product
DC Standard Source
SPS-31
-
Kongter Test & Measurement Co., Limited
SPS-31 is specially designed to test analog and digital DC/AC Voltage meter, Current meter energy meter, DC voltage transducer and Current transducer. It is widely applied for test, production and inspection in research institution, national measurement institution at all levels, and meter manufacturer.
-
Product
Calometric Power Meter
M1-25M/XXE
-
The M1-25M/XXE series instruments are high precision broadband Calorimetric Sensors operating in millimeter and sub-millimeter wave range on a principle of substitution of microwave power by direct current power, using an autocompensating transistor transducer. Calorimetric Sensor is supplied with Calorimetric Power Meter M1-25M (measurement and indicator block), which provides PC connection via USB interface.Calorimetric Power Meter with Calorimetric Sensor provides accurate absolute power measurements in single mode and multimode waveguides (Metal Dielectric Waveguide) which could be a priority for terahertz physics and technology.
-
Product
Temperature and Pressure
-
Encore Electronics manufactures a complete line of rugged and economical instrumentation for temperature and pressure measurement. Our standard, in-stock units can be used for pressure measurement depending on the signal level and output required. Our equipment is available in both DIN rail and modular/rack-mounted configurations for multiple channel capability. Simply specify your output — whether 4 to 20mA , 0 to 10V, or a custom output and Encore can configure a system to match your needs. Whether you need isolated input and outputs using transducer power or computer-controlled units, we will design and build a unit to meet your requirement.
-
Product
Portable Process & Pressure Instruments
-
Time Electronics offer a range of portable process instruments for field and laboratory use. Products include temperature calibrators and simulators for RTD and PT100 applications, and loop instruments for field instrumentation testing of transmitters, transducers and sensors.
-
Product
Transducers
-
You will be able in the following page to select the tranducer that better fit your needs, by selecting the ultrasonic frequency and the diameter of the piezo element, the temperature range and the sizes of the case.
-
Product
Intelligent Panel Mount Meter Amplifier/ Conditioner
MODEL DPM-2
-
The voltage-to-frequency microprocessor makes Transducer Technique's 4-digit panel mount meters the ideal solution for meeting the measurement, display and control requirements of noisy industrial applications, OEMs and system designers. Model DPM-2 accepts any full bridge transducer. Balance and span can be selected via the front keypad, thus allowing the display to read directly in engineering units. Front panel max and tare functions are ideal for industrial weighing applications. Isolated adjustable 9-11 VDC excitation with remote sense and 90 mA drive eliminates the need for external power supplies. Rear screw terminals connectors are included.
-
Product
Water Level, Stage, and Flow Sensors
-
Campbell Scientific offers a variety of sensors to measure water level, stage, and flow: pressure transducers, shaft encoders, radar ranging sensors, sonic ranging sensors, and bubblers. Users often select their sensors based on the site location, required accuracy level, and ease of installation.
-
Product
Transducer Simulator
Model TS-16
-
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch: 0 to 3 mv/v in 15 steps of .2 mv/v
-
Product
Automatic Relay Test Set
DRTS 66
-
DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available.
-
Product
Electrochemical Sensors
-
Electrochemical sensors are devices that provide real-time information about the composition of a system by connecting a chemically selective layer (recognition element) to an electrochemical transducer
-
Product
Pressure Transducers with Serial(485) Interface
P855
-
The Validyne model P855 is a digitally compensated differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments.
-
Product
Transducer Simulator
Model 7
-
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch. 0 to 3 mv/v in 6 steps of .5 mv/v .
-
Product
Digital Inclinometer
ZET 7054
-
ZET 7054 digital inclinometer is used in static systems to sustain platform position (biaxial mode). Low supply voltage, MODBUS protocol application – all this enables embedding of ZET 7054 inclinometer in almost any industrial system. The “Set zero position” function allows to set transducer to zero on each of the axes, and thus, to prevent the platform critical inclination along the coordinate specified.
-
Product
Digital to LVDT RVDT Converters
DLVT
ITA
Computer Conversions Corporation
The SLVT Series are complete, low profile, continuously updating, single channel, Isolated Digital to LVDT Converters used to simulate the output of LVDT's (Linear velocity displacement transducers), RVDT's (Rotary...) and other phase/voltage sensitive AC devices.