Local Loop
-
product
Seed & Node Localization System
GammaPro
The GammaPro System. Simply the most sensitive and precise method for detecting radioactive seeds or locating sentinel nodes.
-
product
Quad Op-Amp Loop
QOAL400
The QOAL400 module is a precision instrument capable of measuring all common parameters of an Op Amp, including AC as well as DC parameters. The QOAL400 has four completely independent channels, which allow a quad device to be tested in a minimum amount of time. Each channel has a full set of resources to measure all common parameters.
-
product
IntelliPoint RF - Loop Powered Level Switch
The IntelliPoint Loop Powered Two Wire provides a capacitance probe level switch with current output and “On-Board” self-diagnostics to ensure reliability and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
product
Loop Tack Tester
Loop Tack Tester is applicable to measure the tack property of adhesive tapes, pressure-sensitive adhesives (PSA), and adhesive materials according to ASTM D6195.
-
product
Local Discomfort Temperature Probe
TP3227K
Temperature probe composed of 2 independent probes, Pt100 sensor used for measuring local discomfort due to vertical thermal gradient.
-
product
Closed Loop Hall Effect Current Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
product
Software Localization Testing Services
Offer Impeccable Globalization and Internationalization Testing Services for software, applications and websites
-
product
Single Loop Controller
1800+
The 1800+ controller is an evolved product from the West N8100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
product
Open And Closed Loop Inverters
VFD
Inverter products support the energy-saving operation of equipment and machinery with fine speed control.
-
product
4-20mA Current Loop USB Data Logger
EL-USB-4
This data logger measures and stores up to 32,000 current loop readings over flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a a 4-20mA d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista
-
product
Local Discomfort Temperature Probe
TP3227PC
Temperature probe composed of 2 independent probes, Pt100 sensor, used for measuring local discomfort due to vertical thermal gradient.
-
product
Loop and Line Powered Level Switch
Safety IntelliPoint
The Safety IntelliPoint level switch provides a capacitance probe level switch with either a current output or relay contacts and “On-Board” self-diagnostics to ensure reliability. This SIL Intellipoint conforms to SIL 2 specifications providing the ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
product
PXI Analog Output/Current Loop Simulator Module - 4 Channel
41-765-004
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Panel-mounted Power Amplifier(Hardware In The Loop Simulation)
PA30Bi
PA30Bi is the panel-mounted type real time simulation amplifier with three-phase current and four-phase voltage.
-
product
Loop Calibrator
6500 LC
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
product
DDS Phase Locked Loop Synthesizer
DDS Series
*Connectorized Package *Programmable Frequencies to 1 GHz
-
product
Single Loop Controller
1460
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
product
Loop Calibrator
Model KM CAL-904-MK1
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
product
Loop Testing
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
product
Temperature Loop Control Setup
ULP-27
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.
-
product
Linear Power Supplies Precision, GPIB or Local Control, Ultra Low Ripple/Noise
Series ATE-DMG
Kepco's 1000 watt instrument-grade digital power supplies, Series ATE-DMG, are linear low-noise power supplies designed to respond very quickly and precisely to voltage and current setting instructions delivered interactively by the GPIB (IEEE 488.2) or from a front panel keypad. When programmed from the bus, the ATE-DMG power supplies respond to the SCPI (Standard Commands for Programmable Instruments) common language for instruments used in an automatic test system.
-
product
Cloud-Based Platform with Global Climate Data & Local Intelligence for Visual Risk Assessments
Climate Risk Manager
Climate Risk Manager is a cloud-based platform brings together global climate data and location intelligence, giving you visual risk assessments, so you can make faster and more accurate decisions on where to invest limited resources and guard against climate risks.
-
product
Active Dual Loop Antenna
KH30936
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
product
Partial Discharge Detection and Localization System for Power Transformers
AE-150™
The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors. Acquired data is sent to Mirador-Tx software where all advanced positioning functions are implemented. This cutting-edge software allows easy data interpretation, reporting and monitoring.
-
product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Helmholtz Coils / Radiating Loops
Formed by a pair of conducting circular coils with many turns, each carrying a current. The coils are separated by a distance equal to the radius of the circular loops.
-
product
Monitoring Loops
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
product
Single Loop Controller
3200
The instrument has the largest red or green digital display in a 1/32 DIN package. In addition to the red or green display the 3200 benefits from three additional multi-colour LEDs to indicate process, alarm and configuration statuses.