Local Loop
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
Single Loop Controller
1462
-
The N4400 is a sophisticated, single loop controller which provides extensive profiling programming options for complex processes. The controller can create a profile with up to 121 segments, store up to 8 programs and configure and store extra programs on a PC.
-
Product
Modular Breakout System for Hardware-In-Loop Simulation
-
Designed in partnership with OPAL-RT Technologies, this Modular Breakout System combines a BoB feature set with the added flexibility of an FIU. By mating the FIU chassis directly to the BoB using our plug-in modules, cabling is minimized, creating a more compact reliable design and improving signal integrity.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 12 Channel
43-765-002
Analog Output Module
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Embedded Local Oscillator Capability
S93084B
-
The S93084B tunes the network analyzer’s receivers to the output frequency of the converter under test without having to access internal LOs or a common reference signals. For converters with embedded LOs, this enables measurements of match-corrected conversion loss/gain and absolute group delay (requires S93082B and S93083B), gain compression versus frequency (requires S93086B), intermodulation distortion (requires S93087B), and noise figure (requires S93029B).
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
Quad Op-Amp Loop
QOAL400
-
The QOAL400 module is a precision instrument capable of measuring all common parameters of an Op Amp, including AC as well as DC parameters. The QOAL400 has four completely independent channels, which allow a quad device to be tested in a minimum amount of time. Each channel has a full set of resources to measure all common parameters.
-
Product
Loop Antennas
-
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
Product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
Monitoring Loops
-
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
Product
Array Solutions K9AY Loop Wire/Mast Kit
AS-AYL-4 WM
-
All materials required for the installation of your receiving loop system, have been included in this kit with the exception of those items listed below under the heading; ‘You will also need. ‘ The specified 8’ x 5/8” copper-clad steel ground rod can be purchased at just about any local hardware store or home center.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Partial Discharge Detection and Localization System for Power Transformers
AE-150™
-
The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors. Acquired data is sent to Mirador-Tx software where all advanced positioning functions are implemented. This cutting-edge software allows easy data interpretation, reporting and monitoring.
-
Product
Level Control Loop Trainer Model
ULP-24P & ULP-24C
-
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Level Control Setup comprises of acrylic measuring tank fitted with Level transmitter, control valve, I to P converter, source tank with water pump and necessary flexible piping for water circulation. The system is mounted on a table top powder coated metal frame. Level transmitter is of capacitance or DPT type sensor. The electronic panel comprises of ADC and DAC card with RS-232 interfaces.
-
Product
Active Loop Antenna
KH30935
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH30935 active loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna has a small outer diameter and light weight, which is convenient for outdoor measurement.
-
Product
Acoustic Target Impact Localization System
ATILS
-
In peace time, for training purposes, artillery units conduct their frequent target practicing.Both the skills of the gunners and the forward observers need to be improved, their communication cycle to be shortened.Forward observing is a dangerous task during war time, causing a justification to find other ways to localize impacts and adjust fires.Furthermore, the sheer lack of a line of sight, because of topography and/or weather, also thrives the need for other solutions to determine the impact coordinates.
-
Product
Loop Meters
-
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
Product
Panel-mounted Power Amplifier(Hardware In The Loop Simulation)
PA30Bi
-
PA30Bi is the panel-mounted type real time simulation amplifier with three-phase current and four-phase voltage.
-
Product
Loop Powered Trip Amplifier With Dual Relay Output
SEM1636
-
The SEM1636 monitors a (4 to 20) mA loop and provides two independent change over trip contacts set to trip at any point within the (4 to 20) mA range.
-
Product
- RS-232 to Current Loop Converter
Model 65A
-
FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
Analog Output Module
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
-
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
Product
Active Loop Antennas / Magnetic Field Probes
-
Is an active, shielded handheld loop antenna with nearly con- stant antenna factor over the entire frequency range. It can be used for testing according to CISPR, MIL, FCC, EN, ISO, ANSI, ETSI and many other standards.
-
Product
RCD Loop Line
-
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
Product
Gunshot Detection & Localization System
-
Information System Technologies Inc.
ISTI’s acoustic transient (e.g. gunshot or any other) event detection and localization technologies exploit low-cost distributed sensors with local processing capabilities. Key benefits include: better capture of muzzle blast and ballistic shockwave in urban environments, lower false alarm, real-time response, robustness to loss of sensor nodes, low hardware complexity, flexibility to configure a dynamic local network and ease in deployment. The Graphical User Interface (GUI) allows for control over the sensors and network while providing an overall assessment picture. Unlike existing gunshot detection and gunshot localization systems, the distributed sensing solutions (algorithms and hardware/software) developed by ISTI can support different sensors including acoustic, seismic and IR.
-
Product
4-20 mA Loop Powered Two Wire Oxygen Transmitter
OxyTrans
-
The Edgetech Instruments Model OxyTrans is an easy to use, accurate and economical way to measure Oxygen at trace and % levels. A simple display and one point calibration allows for a quick start of the instrument.
-
Product
Linear Bench Power Supplies Local Control, Ultra Low Ripple/Noise
Series MSK
-
Kepco's MSK linear power supplies provide a selection of five models, offering 100 Watts of stable benchtop power. They use a high gain linear (series pass) stabilizer circuit for ultra low noise and low ripple output, good stability, and accurate resettability, and they are MIL-STD-461 compliant.MSK's "Preview" switch (d-c on-off) allows voltage and current to be pre-set with the digital meters displaying the set values. At "d-c off," no voltage is applied to the output terminals and no load current needs to be drawn to set the current limit. At "d-c on," the set voltage is applied to the output terminals, the appropriate mode indicator illuminates and the meters indicate actual voltage and current.
-
Product
Helmholtz Coils / Radiating Loops
-
Formed by a pair of conducting circular coils with many turns, each carrying a current. The coils are separated by a distance equal to the radius of the circular loops.
-
Product
PXI Analog Output/Current Loop Simulator Module - 12 Channel
41-765-002
Analog Output Module
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.





























