Standard Transformers
-
product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High Frequency Transformers
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
XDSL Transformers
We manufacture and supply an extensive line of high-performance xDSL transformers, including ADSL, VDSL, Vectored VDSL, VDSL Hybrid, VDSL Line, G.fast, HDSL2 and G.SHDSL transformer and chipsets.
-
product
Control Transformers
ENTES control transformers ensure the safe operation of measuring devices with 24 VAC supply voltage for electical control panels. Input voltages of Control transformers are either fixed (230 or 400V) or selectable with taps (400;230+15-15).
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2TB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1Z1-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2SB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1W1S
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
Electron Multiplication (EM) Standard Image Sensors
EM (Electron Multiplication) is a technology that uses on-chip gain in the charge domain to effectively eliminate read noise from an image sensor. This enables advanced ultra-low light applications that require extreme sensitivity at fast frame rates. Examples include life science applications such as single molecule detection, super resolution microscopy and spinning disk confocal microscopy along with physical science applications such as nanotechnology imaging, Bose Einstein condensates and soft X-ray spectroscopy, and astronomy applications such as adaptive optics and lucky imaging. The inclusion of an additional conventional output allows further flexibility for applications such as true 24 hour surveillance.
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-10
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T30-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Instrument Transformer
Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40G
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
product
Precision Multirange Voltage Transformers
WP-36000
The WP-36000 Transformer is primarily a laboratory standard. The high degree of accuracy and multiplicity of ranges makes this transformer the standard for precision calibration work. With the aid of this transformer, very accurate determination can be made of the ratio and phase angle characteristics of voltage transformers having ratings from 14,400 to 36,000 volts.
-
product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-C
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High Frequency Current Transformers
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-R
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
product
Capacitance Standard Set, 0.01uF To 10uF
16380C
The 16380C is a standard capacitor set consisting of three precision capacitors - 0.01uF (16385A), 0.1uF (16386A), 1uF (16387A),and an optional 10uF (16388A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
product
Multiple Gas Transformer DGA
MINITRANS
Based on the same core technology as the highly successful TRANSFIX the MINITRANS is a lower cost alternative, monitoring three key gases: Hydrogen, Acetylene and Carbon Monoxide (in ppm) plus moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect a wide range of developing faults including arcing.
-
product
NanoCD Standards (NCD)
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2LB-12
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Radius, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0D
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Instrument Transformers Tester
TE30
Calmet Smart Calibration Devices
Electricity meters tester class 0.05 and 0.1. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
product
Standard 2.40 (68.00) - 6.20 (176.00) Battery Probe
BIP-8
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 188Test Center (mm): 4.78Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 60Recommended Travel (mm): 1.52Overall Length (mil): 396Overall Length (mm): 10.06
-
product
Electric Transformer
Zhengzhou SMS Electric Co.,Ltd
For the convenience of the user or the low voltage metering box of electric energy metering, instrument with high precision (0.1)split core type current transformer.
-
product
Three-circuit Transformer DC Resistance Tester
HTZZ-S20A / 219
Wuhan Huatian Electric Power Automation Co., Ltd.
Designed for full capacity transformerthree-phase dc resistance test around group.





























