Filter Results By:
Products
Applications
Manufacturers
- CAMI Research Inc.
product
4-Wire Resistance Measurement | Continuity & HiPot Cable & Wire Harness Testers
An add-on option for the CableEye HVX high voltage cable tester series that permits expanded testing for contact and wire resistance as low as 1 mΩ. After checking for opens, shorts, miswires, and resistance limits, the 4-wire Kelvin measurement applies a user-selectable test current from 10 mA to 1 A to determine connection resistance within 1 mΩ. The resistance profile of a model cable may be stored and used as a basis of comparison during later testing to reveal cold solder joints, faulty crimps, recessed pins, pin contact contamination, improper wire gauge, and stress-extruded wire.This option may be purchased with any new HVX tester, or added as an upgrade to any of your existing HVX testers.
-
product
Kelvin Test Leads
Kelvin Test Probes, Kelvin Test Leads, based on the Parrot™ Clip Invention provide reliable contacts and connections for the Sense and for the Current leads .
-
product
MINIATURE SILICON DIODE TEMPERATURE SENSOR, 2 To 600 Degress Kelvin
Insight Product Company offers SILICON DIODE TEMPERATURE SENSORS CAN BE USED FOR TEMPERATURE Â MEASUREMENTS IN DIFFERENT FIELDS OF CRYOGENIC ENGINEERING AND EXPERIMENTAL PHYSICS. THEY ARE MINIATURE AND OPERATE IN THE TEMPERATURE RANGE FROM 2 TO 600 K.
-
product
Wide Jaw Kelvin Lead Set
6730
Wide Jaw Kelvin Lead Set. True wire four wire lead set with gold plated alligator clips that open to a wide .800? (20.3mm).
-
product
Micro-Ohmmeters
Micro-Ohmmeter is an affordable 7 range, 4-Wire Kelvin based product that is used to test electrical resistance on a wide variety of applications including winding resistance, contact resistance, and component testing. The 720A micro-ohmmeter has an autorange feature (available with NSN package) and is compatible with an RS232C interface (OP-232). Thanks to its wide-range capabilities, ease of use, and CE mark, this micro-ohmmeter is used commonly across the globe.
-
product
Precision Micro Ohmmeter
BS407
High basic accuracy of 0.1%Wide range of 1 µΩ to 20 kΩCurrent reversal switch for detecting thermal EMF effectsCurrent diversion switch for easy zeroingFour terminal measurement using Kelvin clip leads (supplied)Battery operation with built-in charger20mV clamp for "dry circuit" testing
-
product
Digital 125 Amp Battery Load Tester
6033
• Heavy load enables the 6033 to detect bad batteries missed by other electronic testers• Automatically computes the CCA of the battery under load• Kelvin connected digital meter displays the following values:• Current Battery Voltage• Maximum Voltage reading• Minimum Voltage reading• Automatic load cycle• PATENTED• Made in USA of US and Global Components
-
product
Connector Test
A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.
-
product
Milli-Ohmmeter and Bond Meter, Portable, 10 µΩ to 20Ω
R1L-BR
The R1L-B series Ohmmeter/Bonding Tester is a digital microohmmeter designed to measure resistances from 10 to 20 . It is used in applications such as metal bonding, switch, circuit breaker, circuit resistance and other contact and connection resistance tests as well as higher resistance measurements for circuit analysis and resistor testing up to 20 . The instruments utilize the four-terminal, Kelvin technique to eliminate errors caused by the resistance of the leads. Resistance readings are viewed on a 3 1/2 digit display,
-
product
Ultra-High Vacuum Ф4 Scanning Kelvin Probe
The Ф4 Ultra-high Vacuum Scanning Kelvin Probe system gives the user full access to work function measurements under vacuum with the ability to alter the temperature from 77 K to 860 K. The Kelvin Probe measurement has resolution of 1 - 3 meV for a 2 mm tip on a conducting sample. The sample is mounted on a plate that is located on a motorized (x, y, z) translator attached to a stainless-steel vacuum chamber. Phi 4 also comes with a photoemission spectroscopy system with a tuneable source (3.4 - 7.0 eV). The deep ultra-violet (DUV) light spot measures approximately 3 x 4 mm. Absolute work function measurements can be obtained with this system in the range of 4.0 - 6.5 eV with an accuracy of 0.05 - 0.1 eV.
-
product
Short Circuit Locator
A694
The A694 is a short circuit locator designed for fault location in metallic cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A694 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 0.1 ohm and less than 40 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
product
Micro-Ohmmeters
The Micro-ohmmeter performs reliable low resistance measurements with test currents to 10A and resolution to 1. Uses a four-wire Kelvin bridge method, which eliminates test lead resistance for a measurement accuracy of 0.25%.
-
product
Cable Length Meters
CLM-1000
*Measures these AWG wire gages: 18, 16, 14, 12, 10, 8, 6,4, 2 , 1/0, 2/0, 3/0, 4/0*Measures these kcmil wire sizes: 250, 350, 400, 500, 600, 750, 1000*Eight user-programmable settings for other gages*Powered by (6) 1.5V AA batteries*Replacement calibration rods (pair) available as CLM-ROD, UPC 02721*Replacement Kelvin clips (pair) available as CLM-CLIPS, UPC 02722*Feet
-
product
CableEye 4-Wire Calibration Verification Board | Cable & Harness Testers
CB52
The CB52 is intended for periodic calibration verification of the Kelvin 4-wire resistance measurement module – an optional, add-on module that may be purchased with any new hipot system, or added to an existing high voltage tester as an upgrade. To ensure that 4-wire resistance measurements remain accurate, CAMI recommends running the verification check every quarter. A 4-wire measurement module that is out of calibration will give inaccurate results. Some (maybe all) resistance measurements will be incorrect. Consequently, it may Pass what should Fail and, conversely, Fail what should Pass. In other words product yield will be contaminated due to unreliable measurements.
-
product
Ultra-High Vacuum
KP Technology offer a range of Kelvin Probes that work under ultra-high vacuum conditions, choose from single-point or scanning probes to add to your existing vacuum chamber, customize the UHV corner cube or consider the newest addition to the range, the Ф4 ultra-high vacuum scanning Kelvin Probe system.
-
product
Four Terminal Precision Resistors
AH
A-H resistors are constructed with four terminal, isolated voltage and current connections(.i.e. Kelvin Connection) making them suitable for very precise current measurements, current limitations and current regulation in power units, current sources and electronic loads.
-
product
Contact Probes
Rika Denshi Group Contact Probes - specialty probes including fine pitch testing, high frequency testing, high temperature testing, kelvin test, and high current test, as well as standard probes for 0.4mm-, 0.5mm-, 0.65mm-, 0.8mm-, and 1.0mm pitch.
-
product
High Speed Microohmmeter, HI/GO/LOW Outputs
1740
Basic Accuracy: 0.02%Measurement Speed: 10 msRange : 20 m to 20 MResolution : 1 Programmable reference currentsGPIB, RS-232 (model 1740/GPIB) and PLC compatibilityKelvin Klips, Spade Lugs or Kelvin Probes availableEasy to operate and easy to integrate1-year warranty
-
product
Kelvin Clip Test Lead Set
5940
Kelvin Clip Test Lead Set. Ideal for resistant measurementsbelow 1 ohm.
-
product
Micro - Ohmmeter / Milli - Ohmmeter
Basic Accuracy 0.25%Max. Test Current : 5A (120mV) for 7002Max. Test Current : 10A (60mV) for 7272Manual or Auto RangeFour Terminal Kelvin Measurement6 Ranges with 1mV Best ResolutionMeasurement of Resistive and Inductive MaterialsSetting for HI, LO & PASS ReadingsMemory of 3000 Measurements DataProgrammable HI-LO Alarm with memory of 20 DataLarge LCD with Backlight & HOLD FunctionLow Power ConsumptionBattery Operated with AC AdaptorLow Battery (Voltage) AlarmLED indication for Invalid Resistance MeasurementCable Length Measurement in feet & metersUser Interface Software for PC Communication via RS232C(to USB Bridge) cableBuilt-inBatery Chaging Circuit & Calender Clock
-
product
Kelvin IC Clip Lead
16089C
Measure odd-shaped components that you cannot measure using conventional fixtures
-
product
Off-Set Kelvin Test Sockets
This is an innovative and robust contact technology for making Kelvin contact to 0.5mm pitch QFNs. The contact uses a tip that is angled to one side, matched to an orientation that's flat on the tip. Two such contacts placed in opposition will touch the pad within 0.125mm. And because the tip is offset, the probe diameter is a robust 0.39mm and the load board pad pitch remains 0.5mm.
-
product
High Speed Microohmmeter
1750
Basic Accuracy: 0.02%Measurement Speed: 10 msRange : 2 m to 20 MResolution : 100 nProgrammable reference currentsGPIB, RS-232 and PLC compatibilityKelvin Klips, Spade Lugs or Kelvin Probes availableEasy to operate and easy to integrate1-year warranty
-
product
Controlled Atmosphere
KP Technology offer a range of Kelvin Probes that work in a controlled environment including automatic control of relative humidity within the Kelvin Probe housing and integrated nitrogen atmosphere control.
-
product
Scanning Kelvin Probe Microscope
VS-SKP
The Kelvin Probe experiment uses a nondestructive method to determine the relative work function difference between the probe and the sample. Work function describes the energy required to liberate an electron from the surface of a conductor; electrochemists often interpret this as the difference from an electrode’s Fermi Level, average energy of electrons, and that of vacuum.
-
product
Kelvin Clip Set
11062A
Create custom Kelvin probes for 4-wire resistance measurements; set contains only the two gold-plated clips
-
product
Precision Kelvin Holders
MH-4 Series
Integrating Spheres are essential tools for photometricresearch laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary.
-
product
Cryocooler
CryoTel® DS30
The CryoTel® DS 30 Stirling cryocooler offers efficient, reliable, compact and high power cooling to the market in the temperature range of 35 to 250 Kelvin. The DS30 was optimized for applications in which SWAP (size, weight and power) and reliability are concerns. The DS30 consumes considerably less power than other cooling alternatives and requires no maintenance, making it ideal for strategic as well as industrial applications. Both the cold head and the pressure wave generator can be mounted in any orientation. Application examples include semiconductor manufacturing, large infrared detectors, RF receivers or antennas, astronomical telescopes, laser cooling, high-temperature superconductivity, cold traps, and others.
-
product
Conversion Kit for Kelvin Holders
KC-4
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary