Bias Tees
-
product
Bias Tees for Radio Amateurs
Bias Tee for remote power supply of preamplifiers and converters via the coaxial cable.
-
product
Bias Tees From 0.03 MHz To 85 GHz
Pulsar offers a large variety of bias tees that cover frequencies from DC to in both surface mount and connectorized packages. Many models are available with voltages up to 100 volts and currents up to 8 amps and custom requirements are welcomed. Options include higher voltage and current, higher RF input power and a choice of either an RF connector or a feedthrough connection for the DC input port.
-
product
RF & Microwave Passive Components
SHF Communication Technologies AG
SHF’s microwave components are broadband devices suitable up to 110 GHz. Our SHF BIAS TEES are well known but perhaps a slight variation does suit your application even better. DIPLEXERS are bias tees with a certain bandwidth in the low frequency path to combine or separate high frequency and low frequency signals into or out of a single line. DC-FEEDERS are bias tees without the capacitor. Therefore, it provides slightly lower insertion loss in case it is connected to an AC-coupled device which already has a capacitor on its input. Based on our air line construction, these passive components provide resonance-free transmission over the entire operating range.
-
product
Master Oscillator Multiplexer
MOX Series
*Low phase noise OXCO *Interface between VSAT Modems and Frequency Converters *Robust housing is gasket sealed for weather resistance *OCXO iwth low G-sensitivity available *Single or dual multiplexer *Single or dual bias tee *Available in various OCXO frequencies: 10, 50, 100, 120 MHz
-
product
Low Noise Pre-Amplifiers
Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.
-
product
Bias Tees
Mini-Circuits is your complete source for bias tees, handling up to 4 Amps DC and covering 100 kHz to 12 GHz!Rugged coaxial modelsTiny surface mount packages as small as 0.15 x 0.15 inExcellent isolation50 and 75 Ohm models
-
product
Bias T's
Centric RF offers Coaxial Bias T's so that a DC voltage can be applied to the rf signal path. These Bias Tee's (aka bias t) currently are offered with sma and 2.92mm connectors. Bias T's are implemented by attaching a broadband inductor to the circuit trace, with the power rating of the bias tee being determined by the size of the inductor.
-
product
Micro probes 1 MHz up to 1 GHz
MFA 02 set
The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
product
High-Power Low-Loss Pulsed Bias Tees
MBT series
The MBT-series of bias tees is based on Maury's patented broadband capacitor (US Patent 9,614,267) which simultaneously enables the industry's widest bandwidth, lowest insertion loss and lowest return loss in a coaxial bias tee up to 18 GHz. In addition, its unique design makes it ideal for pulsed applications, including pulsed IV and pulsed load pull characterization, without distorting the voltage and current waveforms.
-
product
Micro probes 1 MHz up to 6 GHz
MFA 01 set
The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
product
Bias Tees
A bias tee is a three-port network used for setting the DC bias point of some electronic components without disturbing other components. The bias tee is a diplexer.
-
product
Magic Tee
MHTXE
The MHTXE Magic Tee Hybrid Couplers for millimeter waves are matched power dividers for variety of applications (general purpose power splitters, power combiners, phase measurement circuits, phase / frequency discriminators). The MHTXE Magic Tee Hybrid Couplers are available in waveguide bands between 33 and 170 GHz. These couplers are four-port transmission line components with a port configuration as shown in figure. Operation bandwidth is limited to 20÷90% waveguide operation frequency range depending on performance specifications.
-
product
Bias Tee's
A bias "T" consists of a feed inductor to deliver DC to a connector on the device side and a blocking capacitor to keep DC from passing through to the receiver.
-
product
Bias Networks
Macom Technology Solutions Holdings Inc.
At MACOM we offer 18 - 40 GHz bias networks suitable for DC biasing of PIN diode control circuits. Our bias networks function as both RF to DC decoupling networks, as well as a DC return. These bias networks can also be used as bi-directional reactive couplers for Schottky detector circuits in multimarket applications.
-
product
Magic Tees
As part of our extensive waveguide portfolio, CAES offers a wide range of magic tees and hybrid tees to help add, subtract or divide signals in your designs.
-
product
Regulators For Bias Supply
Renesas' low cost linear regulators generate a low voltage bias supply from intermediate distributed voltages commonly used in telecom and datacom applications. These devices may be used as start-up or as continuous low power regulators.
-
product
DC Bias Current Source
DU2020/2030/2040
Delta United Instrument Co., Ltd.
Frequency: 10KHz - 200KHz Veracity:3% + 3 digitsTiming: 0.1 - 999 H, settable 3 1/2 bits LCD Display
-
product
HIGH FREQUENCY DC BIAS
6565 SERIES
The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.
-
product
DC Bias Current Source
TH1778A
Changzhou Tonghui Electronic Co., Ltd.
The instrument adopts a new generation AC/DC superposition test theory to adapt test requirements for high precision and high frequency. The built-in embedded MCU with high-performance can quickly respond to host and slave machine condition or malfunction and make real time indication, which helps improve the work efficiency. The new designed friendly graphical operation interface, included 5-foot control modes and full touch operation provides convenience and efficiency for users. New file management system with easy, prompt and accurate operation can save a group of real-time setting file and 99 groups of user defined setting files. It can provide pushed information indication and cache 2 real-time information. Being provided with two modes of SCPI instruction systems, it is convenient to set up production lines or single machine test. Also, it can connect with any device with serial port and which refer to the SCPI instruction system design of this machine.
-
product
Zero Bias Schottky Detectors
Fairview Microwave’s line of coaxial packaged zero bias Schottky detectors feature matched inputs for excellent VSWR, voltage sensitivity levels that range from 100 to 500 mV/mW for small signal detection, negative video output polarity, and can withstand maximum input power levels up to +20 dBm CW. Operating temperature range covers 0°C to +90°C and storage temperature of -65°C to +125°C. These zero bias Schottky detectors utilize compact cylindrical package outlines that are made of passivated stainless steel and offer a variety of popular input/output SMA and BNC connector configurations that make them ideal for use with precision test and measurement, instrumentation, and subsystems assemblies. Numerous applications include power measurement, leveling pulsed signal sources, AM noise measurements, radar or missile guidance systems, monitoring system level performance, and pulsed RF measurements.
-
product
DC Bias Current Power Supply
TH1775
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
product
Bias Boards
CUBE
The CUBE Bias Boards are a set of off-the-shelf biasing boards developed to speed-up the integration process of the CUBE CMOS preamplifier family of XGLab. These boards allow to bias both the detector (SDD as standard, other detector upon request) and the CUBE preamplifier.
-
product
Bias Networks
RF and microwave bias networks are used in a wide variety of biasing applications for test and measurement requirements in laboratory and production environments. Bias networks provide the means of supplying DC bias to the center conductor of the coax connector for your device while blocking the DC to the RF ports.
-
product
Bias Network, 45 MHz to 26.5 GHz
11612A
The Keysight 11612A broadband high power bias network can be used in a wide variety of biasing applications for test and measurement requirements in laboratory and production environments. Bias networks provide the means of supplying DC bias to the center conductor of the coax connector for your device while blocking the DC to the RF port.
-
product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62H-4-S
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
DC Current Bias Supply
DC1000A
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.





























