Product
LXI 50Ω Microwave Transfer Switch
60-808-510-010
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-510-007
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Certified Leak Standards
-
Cincinnati Test Systems provides certified, high-performance air flow leak standards and tracer gas leak standards.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-210-005
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-315-009
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-215-016
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2SB-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2G40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-0
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Temperature Stabilized Resistance Standards
-
Measurements International Ltd.
The temperature stabilized resistance standards offer customers the very best in accuracy, and stability. With 3 different models to choose from, covering the full range of resistance values.
-
Product
Microwave Transfer Switch
60-808-410-016
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72HF-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1C1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-210-014
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard Weather Radar Test Panel
TA-3
-
Universal weather radar test panel with integral gyro simulator and monitor jacks. Discrete test jacks for common signals, altitude select switches and a dedicated connector for the RDS series radars. Click on picture for larger view.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40A
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
PXI Dual Transfer Switch 40GHz 50Ω SMA-2.9
40-782-542
Switch Module
The 40-780 Microwave switching module consists of one, two, three or four changeover switches capable of switching frequencies to 18GHz (optionally to 67GHz) in 50Ω or 2.5GHz in 75Ω. The 40-782 module consists of one or two microwave transfer switches. It has a characteristic impedance of 50Ω and is available in versions with maximum operating frequencies of 18GHz, 26.5GHz or 40GHz.
-
Product
Standard for Mass Interconnect Performance
TITAN
-
TITAN sets the standard for Mass Interconnect performance, configuration modularity and long term reliability. TITAN has been designed to offer exceptional configuration flexibility for use with any ATE platform and offers unparalleled I/O density coupled with the widest selection of contact types available for Mass Interconnect.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-410-001
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-F200-1
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
Standard 1.24 (35.00) - 2.94 (85.00) Battery Probe
CCA-006
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-415-004
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4G
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Rubidium/GPS Frequency Standard
PXIe-3352
-