Transfer Standards
-
Product
Windows Embedded Standard
-
Componentized operating system lets you create a custom operating system image to deliver the necessary functionality for the device. Provide device users with a unique and powerful branded experience.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
PXIe Microwave Transfer Switch, Single, 26.5 GHz, 50 Ω, SMA, Failsafe
42-782B-531
Switch Module
The 40-782B-531 (PXI) and 42-782B-531 (PXIe) single failsafe transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 26.5 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Standard Test Systems
WaveCore™ Products
Test System
Textron Systems’ WaveCore family offers a variety of standard test systems with a primary application of satellite payload lab testing. Our systems can be deployed affordably for both production and engineering applications, providing industry-leading levels of data correlation with high system mean time between failures and low mean time to repair.
-
Product
Standard Parameters for Analysis
C-Cell Mono
-
C-Cell Mono is the original system and comes with the standard parameters for analysis. C-Cell Mono takes 1 image of the sample to produce analytical results such as crust wall thickness, size, shape and location. C-Cell Mono is the entry level model of the C-Cell range and offers all the basic image analysis needs for a baker.
-
Product
Intex Beam Gauge & Standard Contacts
-
Developed to measure both internal and external diameters and lengths, the Intex gauge's aluminium extrusion beam gives it a rigid yet lightweight quality, making it ideal for shop-floor environments. The simple release of a locking thumbscrew enables the gauge's measuring direction to be changed quickly and easily.
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-315-002
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1R1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 50 GHz, 50 Ω, SMA-2.4, Failsafe
42-782B-552
Switch Module
The 40-782B-552 (PXI) and 42-782B-552 (PXIe) dual failsafe transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Product
Standard - 6.00 (170.00) - 14.00 (397.00) Feed Through Probe
P2447-1W
-
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 225Test Center (mm): 5.72Full Travel (mil): 300Full Travel (mm): 7.62Recommended Travel (mil): 200Recommended Travel (mm): 5.08Overall Length (mil): 1,145Overall Length (mm): 29.08
-
Product
Coaxial Transfer Switch, DC to 26.5 GHz
87222C
Coaxial Switch
Flexibility is essential in signal routing applications, and the Keysight 87222C 4-port coaxial transfer switch offers just that. It provides exceptional repeatability, low insertion loss, and high isolation. These switches provide simplification of design in signal routing and conditioning applications. The Keysight 87222C can be used in a variety of applications such as, a drop-out switch, switching two inputs and two outputs, or signal reversal switching.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-215-012
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
34945EXT Distribution Board, For Two 87222, L7222C Transfer Switches And Six N181x SPDT Switches
Y1154A
Distribution Board
The Y1150A-Y1155A distribution boards enable simple connections to the external switches. The distribution boards plug onto the 34945EXT and are used to route the power and control signals from the driver module to the switches using standard cables.
-
Product
Vector Network Analyzer (VNA) Simulator – Standard
S94050B
Vector Network Analyzer
S94050B puts flexible S-parameter analysis into your own computer. Dive deeper into measurements captured on a network analyzer or develop and optimize test programs before deploying them onto an instrument.
-
Product
Standard 1.63 (46.00) - 4.50 (128.00) Battery Probe
CP-059-19
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 276Overall Length (mm): 7.01
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-010-004
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1Q1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF800
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation ofpower factor in low voltage instalations
-
Product
Spectral Radiance / Luminance Calibration Standards
-
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74C
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
A Global Standard for Acoustic Absorption Measurements
Alpha Cabin
-
The Alpha Cabin has been especially designed for the measurement of acoustic absorption properties of materials and components used for the noise insulation of vehicles. The Alpha Cabin is significantly smaller than normal reverberation rooms and therefore ideally suited to use within limited space capacities. The acoustic absorption of the Alpha Cabin itself is also very low: Thanks to the high level of sound insulation, background noise in the frequency range of interest is kept to a minimum.
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
Product
Standard Climatic Test Chamber(Environmental Chamber)
-
Guangdong Test EQ Equipment co., Ltd.
Primarily used for accelerated damp heat testing, alternating damp heat testing, constant humidity testing, as well as high/low temperature routine testing, cold resistance testing, low-temperature storage, and adaptability testing under rapid or gradual temperature changes in industries such as aviation, aerospace, electronics, instrumentation, electrical products, materials, components, equipment, and complete machines. It is particularly suitable for Environmental Stress Screening (ESS) testing of electrical and electronic products or for enhancing production efficiency. It enables analysis and evaluation of performance and behavior under simulated environmental conditions.