High Voltage
electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. Also known as: HV
See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV
-
Product
PXI High Voltage Programmable Resistor Module, REDEL Connector
40-230-311-HI
Programmable Resistor Module
The 40-230-311-HI (PXI) and 42-230-311-HI (PXIe) are programmable resistor modules with 2 channels which can be set between 2.5Ω and 62.1Ω with 0.25Ω resolution with maximum voltage of 1.2kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
0 Hz/DC to 14 GHz, Single-Pole, Four-Throw MEMS Switch With Integrated Driver
ADGM1304
-
The ADGM1304 is a wideband, single-pole, four-throw (SP4T) switch, fabricated using Analog Devices, Inc., microelectro-mechanical system (MEMS) switch technology. This technology enables a small, wide bandwidth, highly linear, low insertion loss switch that is operational down to 0 Hz/dc, making it an ideal switching solution for a wide range of RF applications. An integrated control chip generates the high voltage necessary to electrostatically actuate the switch via a complementary metal-oxide semiconductor (CMOS)-/low voltage transistor-transistor logic (LVTTL)-compatible parallel interface. All four switches are independently controllable. The ADGM1304 is packaged in a 24-lead, 5 mm × 4 mm × 0.95 mm lead frame chip-scale package (LFCSP).
-
Product
230V / 36 Amp Load
EL08-230M
-
For High Voltage UPS Battery Testing and Power Supply testing. This particular Load has been designed to operate with UPS Battery Systems and Telecom Rectifiers and Power Supplies with output Voltages in the range of 153V to 230V and is extremely cost effective.
-
Product
High Voltage Breakdown Test Sets
HT-Series
-
Dielectric Voltage Withstand Test or High Potential Test (HIPOT test) is a 100% production line test to verify the quality & electrical safety characteristics of products.
-
Product
Partial Discharge Tester
19501-K/19500
-
Chroma 19501-K partial discharge tester combines hipot test and PD (partial discharge) detector functions in one instrument. The device is capable of a maximum 10kV AC output with leakage current measurement range of 0.01uA and a minimum partial discharge detection of 1pC. The tester is specifically developed to test high voltage semiconductor components and high insulation materials.
-
Product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
Temperature Input Module
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Dynamically Controlled, High Voltage Digital I/O PXI Card With Pin Electronics
GX5055
Digital I/O Module
The GX5055 represents a new level of performance and capabilities for PXI-based digital instrumentation. Based on the proven architecture of the GX5050, the GX5055 offers high performance pin electronics and an enhanced timing generator in a compact, 6U PXI form factor.
-
Product
High Voltage Optically Isolated Probe, 350 MHz Bandwidth. Includes soft-carrying case.
DL03-ISO
-
The DL-ISO enables highest confidence in GaN and SiC device characterization with highest accuracy, best signal fidelity, and comprehensive connectivity.
-
Product
Multi-Channel PD System Locator
PDiagnostic Series
-
Power Monitoring and Diagnostic Technology Ltd.
The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.
-
Product
Safety Test Panel for Geyser
-
Electrical Safety is the most primary and essential product conformity requirement for any product that uses electricity. The clauses of safety testing of electrical products laid by worldwide agencies such as UL, CE, BIS, etc. are stringent. The products need to pass through tests such as the high voltage test, insulation resistance test, earth bond test, leakage current test and so on. And to conform to such tests, SCR Elektroniks have developed for the testing of Geyser. In addition to the conventional safety tests, test for performance is also included.
-
Product
Dual Channel HV Amplifier with Phase Inverter
A800DI
-
This unit contains two independent A800 amplifiers that share common ground reference and power supply. Please see A800 page for technical details.It features also a low voltage phase inverter that inverts the signal applied to the input of channel 1. The resulting signal can then be connected to the input of channel 2 by means of a short BNC cable (supplied). As a result the two outputs operate in counter-phase.
-
Product
High Voltage, High Current Linear Amplifier
P100
-
The P100 is a general purpose linear amplifier having a fixed amplification of 10 times and capable of bipolar high voltage output of ±50V. Any functiongenerator or arbitrary waveform generatoror any othe signal source with amplitude up to ±10 V can be used as an input device.
-
Product
Time Domain Reflectometer
IRG 4000
-
Cable fault location with the BAUR IRG 4000. The IRG 4000 time domain reflectometer is integrated in BAUR cable fault location systems and is used in combination with the system software for locating cable faults in single and three-phase cable systems. Thanks to the novel operational concept, cable faults can be located more rapidly and easily with IRG 4000. The high-performance industrial PC and improved measurement parameters allow for a precise cable fault location in all cable types. The well-proven and continuously enhanced methods are available for the cable fault location as well as the newly developed Conditioning SIM/MIM** method which makes it even more effective and quick to locate wet cable faults that are difficult to detect. The SIM/MIM technology with 20 reflection measurements per HV pulse allows for selecting the best reflection image for a very precise determination of the fault distance.* Easy operation thanks to intuitive operational concept*Maximum precision with high resolution and sampling rate*Precise fault location methods for every type of fault
-
Product
9-Pin D-Type, Female, Straight PCB Mount, HV
40-963-009-SF-HV
D-Sub PCB-Mount Connector
9-Pin Female D-Type Connector, High Voltage - Straight PCB Mount
-
Product
6 Channel 500 V/3 mA VME HV Power Supply
V6519
-
The V6519 is a 1-unit wide VME 6U module housing 6 High Voltage Power Supply Channels 500V, 3mA. The board is available with either positive or negative output polarity; mixed version with 3 positive and 3 negative channels is also available.
-
Product
PXI High Voltage Programmable Resistor Module, REDEL Connector
40-230-344-HI
Programmable Resistor Module
The 40-230-344-HI (PXI) and 42-230-344-HI (PXIe) are programmable resistor modules with 1 channel which can be set between 4Ω and 1.5MΩ with 2Ω resolution with maximum voltage of 1.2kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
Cable Assembly, 9-Pin D-Type Female to Unterminated With Tinned Ends, 0.5m, HV
A009DF4-T-HA050
Cable Assembly
A range of 9-Pin D-Type High Voltage cable assemblies with unterminated connections on one end, constructed from PTFE Type C insulated wire. The unterminated connections are coded to match the connector pin designation.
-
Product
Compact Testers
-
Adaptronic wiring testers of the compact class are available as low voltage testers and also as high voltage testers, as KT version with display and keyboard and as NT version with the grafical user interface NT Control. With max. 5120 test points (NT 600) adaptronic wiring testers of the compact class are predestined for voluminous testing jobs and large products to be tested. Whether with adapter cables, test tables, test consoles or adapter consoles - the wiring testers of the compact class can also be used everywhere.
-
Product
Voltage Meter
MN6SV
-
The M-module is intended for use as part of an automated measuring system for monitoring any object, the output signal of which is high voltage, for example, telemetry circuits, etc.
-
Product
37-Pin D-Type Female Solder Pin HV
92-960-037-F-HV
D-Sub Female Connector
This accessory is designed to allow users to directly terminate a cable with soldered connections. When the product is used without a backshell users should make their own cable strain relief arrangements and ensure appropriate electrical safety precautions are observed.
-
Product
8-Ch, 16-Bit Isolated Analog Input EtherCAT Remote I/O Module
AMAX-4817
Analog Input Module
Suitable for EtherCAT networks8-ch, 16-bit analog input channels with 2,500 VDC isolation±275 V high common-mode voltage rangeQuick removable European type connectorSupports EtherCAT Distributed Clock (DC) mode and SyncManager modeTwo rotating switches for up to 256 slave IDs
-
Product
9 Pin D-type Connectors & Cables
-
These standard voltage and high voltage 9 Pin D-type connectors are used for both PXI & LXI switching and simulation products for low density applications.
-
Product
Test Enclosures
Enclosure
The HV test hood, developed by us in accordance with EN50191 standard (erection and operation of fixed and temporary electrical test installations), is designed for testing large quantities in ongoing production. The ergonomic design ensures fatigue-free operation even during repetitive work sequences. Equipped with all safety-relevant functions, such as safety switch and locking of the hood cover during the test sequence, the operator is optimally protected at all times.The interchangeable adapter plate within the test cell allows quick adaptation for different test conditions and test situations.
-
Product
Ignition Pulse Detector
IP-3100
-
The IP-3100 enables ignition pulse detection of gasoline engines with high sensitivity. The rotation speed can be easily measured by clamping the primary side cord (low voltage), the secondary side cord (high voltage), and current cable of the electronic distributor. The IP-3100 is used with the tachometer made by Ono Sokki.
-
Product
PXIe High Voltage Programmable Resistor Module, REDEL Connector
42-230-251-HI
Programmable Resistor Module
The 40-230-251-HI (PXI) and 42-230-251-HI (PXIe) are programmable resistor modules with 2 channels which can be set between 4.5Ω and 2.95MΩ with 0.25Ω resolution with maximum voltage of 1.2kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
High Voltage Insulating Tester
-
Suitable for preventive maintenance of gapless arresters.By simply clamping around the ground wire of an arrestor with a clamp CT, it detects leak current and leak current resistance components.
-
Product
Isolation and Power Solutions
-
Silicon Labs' innovative digital isolation and power product portfolio includes CMOS digital isolators, isolated gate drivers, isolated current sensors, isolated system products and Power over Ethernet (PoE) families. These mixed-signal IC solutions leverage Silicon Labs' superior isolation and high voltage expertise to enhance power system performance, flexibility and reliability while reducing system size and cost. The entire isolation portfolio supports isolation voltages up to 5 kV.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
Temperature Input Module
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
High-Voltage & Control Measurement
-
PMK Mess- und Kommunikationstechnik GmbH
As a developer and manufacturer of high-voltage and control measurement technologyand high-voltage safety accessories, ROSS Engineering Corp is a long-standing partner of PMK.We are pleased to make this coveted technology accessible to you through our international sales network.
-
Product
400 MHz High Voltage Passive Probe
HVP120
-
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.