Thermocouple Calibrators
-
Product
Digital Load Calibrator
HS 2000
-
Jinan Testing Equipment IE Corporation
The load cell calibrator is used to calibrate the load of testing machine and hardness tester, and also can be used for force measuring. It is digital display type with high accuracy of less than +0.3%, and easy to operate
-
Product
Infrared Calibration
-
Optical pyrometers can be calibrated from 800 to 2300C using NIST certified ribbon filament lamps and temperatures up to 3500C using a graphite arc furnace. Infrared thermometers can be calibrated from -30C to 2300C utilizing state-of-the-art blackbody sources and transfer standards.
-
Product
SparkFun Qwiic Thermocouple Amplifier
MCP9600 (Screw Terminals)
-
The MCP9600 Breakout is a high accuracy Thermocouple Amplifier equipped with an I2C interface, accessed over our Qwiic system. Inside the chip are two temperature sensors, one for the thermocouple itself (the hot junction) and one for the chip itself (the cold junction). As a result, the MCP9600 can read both the ambient temperature and the temperature of whatever you're trying to measure! The MCP9600 can do both with a resolution of 0.0625°C, and an accuracy of ±1.5°C (worst-case). The MCP9600 Thermocouple Amplifier is one of our many Qwiic compatible boards! Simply plug and go. No soldering, no figuring out which is SDA or SCL, and no voltage regulation or translation required!
-
Product
Electromechanical Calibration for Transducer
ELCS-500
-
Jinan Testing Equipment IE Corporation
The electromechanical calibration system is specially designed for the calibration of transducers. The calibration for transducer can calibrate the load cell accuracy within +/- 0.5%.
-
Product
Calibration & Repair Services for Instruments in Process Control
-
Meeting customer needs is our number one priority. Hastings Instruments offers free technical support as well as personalized one-on-one customer service through a diverse organization of field Customer Service Representatives and Distributors. We have more than 50 field Customer Service Representatives that are situated to provide local support throughout the world.Additionally, reaching our Customer Service Department is only a toll-free number away (USA) and is available for your convenience. Faxing or E-mailing your question first will assure that it is reviewed before you speak to a Customer Service Representative. Also, following the steps listed in our trouble shooting guides (included in each product instruction manual) may help direct you to the appropriate department before you pick up the phone to call.
-
Product
Multi-Axis Calibrator
XM-60
-
XM-60 is a laser measurement system capable of measuring errors in six degrees of freedom along a linear axis, simultaneously from a single set-up. It provides a powerful diagnostic tool measuring all geometric errors in the axis from a single capture. For users of volumetric compensation XM-60 provides quick and accurate method of data population. All measurements are made optically allowing use in any orientation.
-
Product
Acoustic Calibration Services - IEC
-
Acoustic Calibration Services - IECMake sure you measure correctly! We offer traceable acoustic calibration services according to international IEC and ANSI standards and ensure that your instrument accurately indicates the required measurement parameters. Calibrations are documented, traceable, and digitally signed in cooperation with an accredited calibration laboratory.
-
Product
Dose Calibrator
CRC®-55tR
-
As a combination of the new CRC®-55tR Dose Calibrator and Well Counter, the CRC-55tW dose calibrators provide advanced features with the speed and accuracy you need to measure activity and prepare doses.
-
Product
Exhaust Gas and Wheel Space Thermocouple
EGT
-
AMETEK Exhaust Gas (EGT) and Wheel Space Frame Turbine Thermocouples meet the specific operational and performance requirements for REPLACEMENT and RETROFIT Frame gas turbine applications. AMETEK's expertise in solving creep, stress, rupture, corrosion, EMF drift, and other problems affecting sensor performance has resulted in a robust line of single and dual element thermocouple designs. Typical applications include wheel space and exhaust gas temperature monitoring.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Two-way Wireless Thermocouple Temperature Data Logger with LCD
RFTCTemp2000A
-
The RFTCTemp2000A is two-way Wireless thermocouple based temperature data logger with LCD. Transmits up to 2000' maximum (outdoors unobstructed). Built-in memory also stores data internally. Features a built-in temperature sensor for cold junction compensation (CJC). An external thermocouple probe is required (not included). Accepts J, K, T, E, R, S, B, and N type thermocouples.
-
Product
Thermocouple – Pt100 Thermometer
HD2178.1
-
Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N, large display.
-
Product
Multifunction Calibrators
-
These field and bench calibrators source, simulate, and measure pressure, temperature, and electrical signals with exceptional precision. They can automate calibration procedures, store data, and even calibrate and troubleshoot HART-compatible devices. Our bench calibrator can even be used to calibrate our field calibrators. Also find here 5.5- and 6.5-digit bench multimeters for to assist with a variety of general test and calibration applications.
-
Product
Air Data Calibration
-
Fluke calibration offers digital pressure monitors, air data calibrators and laboratory standards for air data pressure range calibrations. Each of these systems feature pressure ranges, measurement units and features specific to calibrate air data test sets and RVSM compliant air data instruments. Models include 2468 Ruska and ADCS-601 DHI primary level standards; 7750i Ruska air data controller/calibrator and RPM4-AD DHI reference pressure monitor.
-
Product
Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit
72-1015 CAL
-
The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Product
Multifunction Process Calibrators
-
Practical Instrument Electronics, Inc.
Tired of carrying large, cumbersome multifunction calibrators with their confusing buttons and menus? PIE multifunction calibrators are small, easy to use and extremely accurate. The unique and intuitive EZ-DIAL Double Click Menu makes them simpler to setup than larger calibrators with their complicated button filled panels and confusing menus. Use PIE right out of the box instead of wasting time learning to use more complex calibrators. PIE has a multifunction calibrator to fit your needs from the PIE 820 with a single display to the advanced troubleshooting capabilities of the PIE 830.
-
Product
PLTS Measurement And Calibration
N19303B
-
The new Physical Layer Test System (PLTS) 2024 is the industry standard for signal integrity measurements and data post‑processing high-speed interconnects, such as cables, backplanes, PCBs, and connectors. Signal integrity laboratories worldwide have benefited from the power of PLTS in the R&D prototype test phase.
-
Product
Thermocouple Vacuum Gauge Tubes for Medium Vacuum
DV-6 Series
-
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily installed into vacuum systems and when properly excited, generates a thermoelectric voltage to provide a vacuum pressure measurement based on gas density. The DV-6 thermocouple vacuum gauge tube fully compensates for temperature and rate of temperature change.Thermocouple gauge tubes are calibrated on vacuum systems that contain N2 or Air, but can be used with other gases. Additionally, thermocouple gauges and their controllers can be recalibrated when a replacement thermocouple gauge tube is installed, following instructions in the manual. However, our DB-20 reference tube is available to confirm meter/controller performance. A complete line of installation accessories are also available to simplify the integration of our thermocouple gauge tubes into a variety of vacuum systems. Our goal is to provide “one less thing to worry about”, when performance matters! With a wide range of meter, fitting, relay and output options, the DV-6 series provides a reliable pressure measurement in numerous industries and applications.
-
Product
Test gas - for calibration
-
Test gases for gas measuring and gas warning devices.Enables the functional control and calibration of measurement technology.
-
Product
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)
510181111
-
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)Compatible with 410130116, ITA, i2 MX, 22 Slot VTAC/SIM Insert, EMI, and XL version 410130133Not loaded. Thermocouple patchcords need to be purchased separately.
-
Product
PXI Millivolt Thermocouple Simulator Module - 8 Channel
41-760-004
-
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
Product
Automated CMM Calibrated for High-Production Shop Floor Inspection
CMM Master
-
The CMM Master provides process control by delivering optimal price and performance to your application. The system brings highly repeatable, thermally insensitive, versatile, and programmable inspection to the shop floor.
-
Product
Decade Box, Calibrated W/Data, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL D
-
The 72-7270 CAL D from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Thermocouple, Insert, Receiver, SIM, 8 Pos, 3 Slot (not loaded)
510180111
-
Thermocouple, Insert, Receiver, SIM, 8 Pos, 3 Slot (not loaded)Compatible with 310130113 Receiver, i2 MX, 22 Slot VTAC/SIM Insert, EMINot loaded. Thermocouple patchcords need to be purchased separately.
-
Product
Blackbody Calibrators
-
Omega offers a diverse portfolio of blackbody calibrators used to calibrate infrared pyrometers. Blackbody calibrators use a high emissivity target plate or target cavity to minimize error.
-
Product
Calibration Lead - Precision Resistor Modules
40-975-037-02-1m
-
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-293 and 50-293 enabling calibration via an external DMM.
-
Product
Calibrate Camera RAW Image Files
SpyderCUBE™
-
Accelerate RAW processing by taking one reference shot under any light condition to set the white balance, exposure, black level and brightness right from the start for your entire series of photos.
-
Product
Calibration Segment Arm
-
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Segment arm is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
Product
Acceleration Pickup Calibrator
VX-1100A
-
VX-1100 is for a piezoelectric type accelerometer which is widely used for measuring vibration. This compact calibrator is effective for checking operation(sensitivity) sensors before measurement to acquire accurate data.Built-in sensor amplifier and display in one unit allows direct reading of the sensitivity. This calibrator excites the sensor at a frequency of 159 Hz and acceleration of 10 m/s2 rms, and the sensor outputs can be used as calibration signals for a vibration measuring system.
-
Product
16 Channel Thermocouple Monitor
SR630
-
Stanford Research Systems, Inc.
The SR630 is a 16-channel thermocouple monitor designed to read, scan, print and log temperatures or voltages. You can use any one of seven standard thermocouple types to read temperatures from -200 °C to +1700 °C.