Product
MULTI-FUNCTION AVIONICS TEST SET
TR-220
-
Tel-Instrument Electronics Corp.
The TR-220 provides test capability for Traffic and Collision Avoidance Systems (TCAS), Distance Measuring Equipment (DME) and Transponders (Modes A, C, and S). The TR-220 features state-of-the art design technology. Microprocessor control results in easy-to-use operation that requires minimum amounts of training. Setup menu allows storage of various test parameters to facilitate quick recall of test conditions.
-
Product
Power Factor Transducer
*(0.2%ACC.) : TDPF. *(0.5%ACC.) : TSPF
-
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C± 5 °C• High Dielectric Strength 2.6KV AC / Min, Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
Product
PXIe-5673E, 6.6 GHz PXI Vector Signal Generator
781263-01
Signal Module
6.6 GHz PXI Vector Signal Generator—The PXIe‑5673E is a wide-bandwidth module that, when combined with the appropriate software, can generate a variety of signals. With the Modulation Toolkit for LabVIEW, it can generate different waveforms including AM, FM, CPM, ASK, FSK, MSK, PSK, QAM (4‑, 16‑, 64‑, and 256‑QAM), multitone signals, arbitrary waveforms, and many others. In addition, you can combine these vector signal generators with standard-specific software to generate signals for GPS, GSM/ EDGE/WCDMA, WLAN, WiMAX, DVB‑C/H/C, ISDB‑T, ZigBee, and others. With PXIe‑5673E stream‑from‑disk capabilities, you can generate continuous waveforms that are up to several terabytes in length.
-
Product
DC/AC Inverter 3000 W
ODS-3000-7154-T
-
DC/AC inverter with 3000 W from Premium | input ranges from 25.2 - 45 VDC | output at 230 VAC | operates in temperatures from -25 to +70 °C | approved for EN45545-2 fire and smoke | railway version
-
Product
1-2 Independent, Dual Redundant 1553 Channels on Small Mezzanine
MEZ-E1553
Ethernet Interface
From our popular ENET product, the MEZ-E1553 is a small, rugged mezzanine product that can easily be integrated into your system design. Alta provides full reference schematics, design notes, STEP 3-D Files, and sample ESS test programs. Guaranteed 1553A/B/C compliant with AS4111 5.2 Protocol Test reports.
-
Product
Cable Assembly. 9-Pin D-Type Male To Unterminated With Ferrules, 1m, HV
40-972-009-1m-MU-HV
Cable Assembly
A range of 9-Pin D-Type High Voltage cable assemblies with unterminated connections on one end, constructed from PTFE Type C insulated wire. The unterminated connections are coded to match the connector pin designation and include crimped on ferrules to ensure the wire strands cannot breakwhen they are terminated.
-
Product
DC/DC Converter 60 W
CTS-60-6842
-
DC/DC converter with 60 W from Premium | input ranges 28.8 - 60 VDC | output 48 V | operates in temperatures from -25 - +85 °C | designed according to EN50155
-
Product
Cable Assembly, 50-Pin D-Type, Male to Male, 0.5m HV, Exit Towards Pin 1
A050DM5-050DM5-HA050
Cable Assembly
50-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24 AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assemblies can be secured to the mating part by a screwlock.
-
Product
PXIe-5673E, 6.6 GHz PXI Vector Signal Generator
781340-04
Signal Module
6.6 GHz PXI Vector Signal Generator—The PXIe‑5673E is a wide-bandwidth module that, when combined with the appropriate software, can generate a variety of signals. With the Modulation Toolkit for LabVIEW, it can generate different waveforms including AM, FM, CPM, ASK, FSK, MSK, PSK, QAM (4‑, 16‑, 64‑, and 256‑QAM), multitone signals, arbitrary waveforms, and many others. In addition, you can combine these vector signal generators with standard-specific software to generate signals for GPS, GSM/ EDGE/WCDMA, WLAN, WiMAX, DVB‑C/H/C, ISDB‑T, ZigBee, and others. With PXIe‑5673E stream‑from‑disk capabilities, you can generate continuous waveforms that are up to several terabytes in length.
-
Product
VME J2 3 slot
101VMEJ203-0900R
-
VME J2 backplane 3 slot, compliant with ANSI/VITA 1-1994. The A+C rows are bussed in all slots. Also, row B has onboard, inboard termination.
-
Product
Incubator
I
-
In the laboratory, the Memmert incubator I is ideal for all applications with temperatures up to +80C specifically for incubating living cultures at +37 C. Thanks to the finely-tuned control technology, critical temperature overshoots are completely ruled out, valuable loads are therefore warmed up particularly carefully in this highly precise microbiological incubator.
-
Product
Split Core Current Transformers
-
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
Product
Omnidirectional Hotwire Probe
AP3203
-
Omnidirectional hotwire probe with cable for Thermal Comfort measurements. Measuring range: air speed 0.02...5 m/s, temperature 0...+80 °C.
-
Product
Modular Open Systems Approach (MOSA) Solutions
-
NAI’s Modular Open Systems Approach (MOSA) solutions provide customers with pre-configured, pre-validated, rugged military embedded solutions that save development time and cost while reducing program risk. These Flexible, Adaptable, Configurable, Modular and Expandable Systems Eliminate custom designs and redesigns by taking advantage of NAI’s Configurable Open Systems Architecture (COSA). NAI's full suite of MOSA Solutions are ARM® Cortex®-A53 processor-based and are ruggedized to withstand -40° C to +71° C and qualified to MIL-STD-1275D & MIL-STD-704A with 50 ms holdup (VITA 62 power supply); MIL-STD-461F and MIL-STD-810G.
-
Product
CX4000 – FTIR Gas Analyzer
-
Gasmet CX4000 is an industrial multi-component FTIR gas analyzer for continuous emission monitoring applications, integrated into a Continuous Emissions Monitoring system (CEMS II e). It can be used to measure up to 50 components simultaneously, and additional gases can be easily added without any hardware changes. The corrosion-resistant sample cell is heated up to 180 °C, which makes CX4000 an ideal tool for analyzing trace concentrations of pollutants in wet, corrosive gas mixtures.
-
Product
ASCB Bus Analyzer And Generator
DataTap-10
-
Innovative Control Systems, Inc.
The DataTap 10 is our most advanced ASCB Bus Interface Product available that receives and records all versions of ASCB including ASCB-A, B, C, D, and Enhanced ASCB. The unit can also optionally transmit on ASCB-D and Enhanced ASCB for simulation purposes. The device is available in 2 configurations. We offer the standard DataTap-10 in a black anodized aluminum case and for Flight Test we offer a ruggedized version. Both of these are listed below.
-
Product
Electronic Circular Temperature Chart Recorder
-
The Circular Temperature Chart Recorder’s external stainless steel probe allows you to measure the temperature of air, gas, liquids and semi-solids. The temperature chart recorder has a quartz clock movement, motorized chart advance and temperature accuracy of ±2°F (±1°C). The chart recorder comes in °F or °C models and runs on 120V or 220V AC, 50/60 Hz. A rear compartment houses 8 AA alkaline batteries, providing up to 48 hours of continuous recording in the event of a temporary power loss.
-
Product
3U CompactPCI® Serial XMC Module Carrier Blade
cPCI-A3XMC
Carrier Board
- 3U 4HP CPCI-S.0 peripheral- One XMC slot- Operating temperature: -40°C to 85°C with qualified components
-
Product
Cross Development Tools
ColdFire V1
-
All Cosmic C Cross Compilers for Windows include IDEA - Cosmic's own integrated development environment which is preconfigured for the ColdFire family of processors. IDEA is designed specifically for developing embedded applications with Cosmic compilers. IDEA integrates an editor, project manager, graphical smart build/make facility, program analyzer, link file generator, documentation manager and ZAP debugger into one easy to use environment running under all popular Windows versions. Click here for more information about IDEA.
-
Product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
779521-01
Strain/Bridge Input Module
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
Product
Mini Coax, Contact, ITA, RG316
610103115
Coax Contact (ITA)
Primary mating contact 610104114. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 mΩ @ 0.5 Amp & always < 10 mΩCable Specifications RG316Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
Product
Liquid Nitrogen Generator
-
The Liquid Nitrogen Generator is your reliable and efficient on-site plug and produce cryogenic solution. With a small footprint, low power consumption and no need for cooling water or water chiller makes the TRITON2+ and Triton-2 the best solutions available on the market. With integrated cooling fans can operate with air cooling up to +32°c ambient temperatures making it suitable to operate in most parts of the World. Simply connect the power and press start for the machine to automatically produce liquid nitrogen when needed. The safe front flask dispenser makes dispensing LN2 safer than ever with other options such a s a rear hose connection available to connect to freezers.This makes possible to cryopreserve important biological samples in a stable and reliable manner.Nitrogen is used primarily:food industry, Medical treatments, and Also Liquid nitrogen used for medical cooling systems for the preservation of cord blood tissue and eggs
-
Product
sbRIO-9207, Non-Enclosed, 500 S/s, 16-Channel C Series Voltage and Current Input Module
781069-01
Current Input Module
Non-Enclosed, 500 S/s, 16-Channel C Series Voltage and Current Input Module - The sbRIO‑9207 is a combination voltage and current input module designed with industrial systems in mind. It features eight current and eight voltage input channels, with built-in noise rejection. Non-enclosed modules are designed for OEM applications.
-
Product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74E-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
NI-9202, ±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module
784400-01
Voltage Input Module
±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module - The NI-9202 has excellent flexibility to meet the needs of your applications. The module has 16 simultaneous sampling, differential input channels to create large, distributed systems in a rugged form factor. It also has configurable filters to eliminate noise in your system while maintaining low-latency to be used in control systems.
-
Product
Datalogging Digital Sound Level Meter with RS-232 Software and Cable
735
-
Whether you are testing for OSHA compliance, quieting equipment, or monitoring the roar of a stadium crowd, B&K Precision's Sound Level Meters can get the job done. The model 735 Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T156
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
C/I Tracers
-
*Advanced bi-directional sensing technology*Superior sensitivity and functionality providing for accurate tracing and locating*Ergonomic receiver with information-rich full-color graphical LCD*Visuals and audible signal provide quick and easy to understand tracing feedback*Traces concealed wiring, locates junction boxes, and finds breakers for live or open circuits*Locates and identifies blown fuses*inds shorts and breaks in conductors
-
Product
Thermocouple, Contact, Receiver, Alumel, Type K (°C)
610113132
Thermocouple Contact (Receiver)
Primary mating contact 610113134.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
Product
TSE-12-A Thermal Shock Chamber
-
Did you think that getting a thermal shock chamber was too expensive, required special utilities, and half your lab-space? The TSE-12 thermal shock chamber is the solution. Only 26 inches wide, the TSE-12 transfers product loads between cold and hot zones with a temperature range of -65°C to 200°C.