Filter Results By:
Products
Applications
Manufacturers
IEPE
standard for accelerometers.
-
product
FD-11634, 8-Channel Sound and Vibration Input Device for FieldDAQ
786471-01
The FD-11634 can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. The device also works with smart TEDS sensors, delivers a wide … dynamic range, and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals and have built-in anti-aliasing filters that adjust to your sample rate. This device is IP65/IP67-rated to be dust-tight and water-submersible and can sustain 100 g shock and 10 g RMS vibration in -40°C to 85°C environments. You program the FD-11634 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. When used with NI software, this device can provide processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module
781369-01
204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
PXIe-4464 , 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module
783087-01
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-03
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Low Outgassing ICP® Accelerometers
Low Outgassing ICP® (IEPE) Accelerometer Types & Their Applications.
-
product
PCB GPTA02, 10 mV/g, IEPE, 1 Hz to 5 kHz, Accelerometer, Triaxial Vibration Sensor
784169-01
The PCB GPTA02 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB GPTA02 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
product
Hardware
Metra Mess- und Frequenztechnik in Radebeul e.K.
*Compact measuring modules *Connect two IEPE accelerometers to your PC*USB-Interface facilitates installation*No settings necessary*Power supply via USB
-
product
PCB IMIB01, 100 mV/g, IEPE, 15 kHz, 2-Pin, Accelerometer, Industrial Vibration Sensor
784176-01
The PCB IMIB01 is an industrial Vibration Sensor designed for permanent installations. This sensor helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound
-
product
PCB IMID01, 100 mV/g, IEPE, 2-Pin, Accelerometer, Industrial Vibration Sensor
784175-01
The PCB IMID01 is an industrial Vibration Sensor designed for permanent installations. This sensor helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. The PCB IMID01 features a sensitivity range of 100 mV/g and uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The sensor supports the IMI Industrial Accelerometer Cable as well as the MIL2M-Breakout Cable.
-
product
24-Bit High-Resolution Dynamic Signal Acquisition and Generation Module
PCI-9527L
The PCI-9527L is a high-performance, 2-CH analog input and 2-CH analog output dynamic signal acquisition board. This board is specifically designed for audio testing, acoustic measurement, and vibration analysis applications.The ADLINK PCI-9527L features two 24-bit simultaneous sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate up to 216 KS/s at high resolutions, making it ideal for higher bandwidth dynamic signal measurements. The sampling rate can be adjusted by setting the onboard DDS clock source to an appropriate frequency. All channels are sampled simultaneously and accept an input range from ±40 V to ±0.316 V. The PCI-9527L analog input supports software selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors.
-
product
PXI Sound and Vibration Module
PXI Sound and Vibration Modules are designed specifically for applications like audio test and measurement, noise and vibration diagnostics, machine condition monitoring, automotive test, noise, vibration, and harshness(NVH) analysis, and laboratory research. They provide software-configurable AC/DC coupling, antialiasing filters, and IEPE conditioning to ensure precision measurements with microphones, accelerometers, and other transducers with large dynamic ranges.
-
product
USB Sound And Vibration Measurement Bundle
The USB Sound and Vibration Measurement Bundle provides a portable, USB-based sensor measurement system that helps you measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes.
-
product
PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module
784277-01
1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.
-
product
PC USB Noise & Vibration Measurement Systems
IEPE Sensor Based Measurement Systems, Charge Amplifier Based Measurement Systems, All-in-One Integrated Vibration Measurement Systems
-
product
PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module
779687-01
204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.
-
product
IEPE Triaxial Whole Body Accelerometer – 1000 mV/g
HD2030MSP
HD2030MSP is an accelerometer suitable for the measurement of vibrations transmitted by seats to the occupants of passenger and work vehicles.
-
product
PCB TA01, 5 mV/g, IEPE, Accelerometer, Triaxial Vibration Sensor
780990-01
5 mV/g, IEPE, Accelerometer, Triaxial Vibration Sensor - The PCB TA01 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB TA01 features a sensitivity range of 5 mV/g.
-
product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-02
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
IEPE Triaxial Accelerometer – 10 mV/g
HDP356A02
Triaxial accelerometer miniature for hand-arm measurement, ICP, 10mV/g, weight 4g, range 500 g pk
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784397-01
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Universal Accelerometers
Metra Mess- und Frequenztechnik in Radebeul e.K.
There are models with charge output and with IEPE compatible voltage output. The transducers of KS series have a shear type sensing element making them less susceptible to thermal transients and base strain. The accelerometers of KD series have a compression type sensing element combining rugged design, precision and low cost.
-
product
Signal Conditioning
To get most out of high-quality sensors, accurate, low-noise processing of the sensor signals that are emitted is essential. Kistler offers an attractive portfolio of solutions for signal processing and subsequent data digitization. Piezoelectric (PE) sensors with a charge output require a so-called charge amplifier. On the other hand, piezoelectric sensors with integrated electronics (IEPE) are supplied by Piezotron couplers which decouple and amplify the signal.
-
product
Digital Telemetry Solutions
For measurements on rotating components and moving machinery, imc offers modern telemetry systems for a wide variety of tasks: whether single-channel torque monitoring of a rotating shaft, multi-channel strain gauge and temperature measurements on a train wheel-set or non-contact power measurement on a vehicle drivetrain in harsh environments. There are transmission electronics available for a large variety of sensors, such as strain gauge (quarter-, half- and full-bridge), thermocouples, PT100/1000, as well as IEPE sensors and voltage signals.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-01
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
4-CH 24-Bit 128kS/s Dynamic Signal Acquisition USB 2.0 Module
USB-2405
The USB-2405 is a 24-bit high-performance dynamic signal acquisition USB module equipped with 4 analog input channels providing simultaneous-sampling at up to 128 kS/s per channel. The USB-2405 also features software selectable AC or DC coupling input configuration and built-in high precision 2 mA excitation current to measure integrated electronic piezoelectric (IEPE) sensors such as accelerometers and microphones.
-
product
IEPE Triaxial Accelerometer – 1000 mV/g
HDP356B18
Triaxial accelerometer high sensitivity, ICP, 1V/g, weight 25g, range 5 g pk
-
product
Vibration Monitoring
Encore Electronics offers a full line of vibration monitoring equipment, ranging from DIN-rail mounted accelerometer signal conditioners to complete multi-channel monitor / alarm cabinets. Most are equipped with a 4mA power source for IEPE (Integral Electronic Piezo-Electric) transducers.