Winding Resistance
-
Product
Winding Resistance Meter
TRM 104
-
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
Product
Winding Resistance Meter
TRM 50+
-
SCOPE introduces 50 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 50 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
Product
Portable Winding Resistance Tester
-
1. Handheld winding resistance meter2. Conversion function for standard temperature resistance.3. 500 test data can be saved and download by flash disk.4. Temperature testing function.
-
Product
Winding Resistance Tester
JYR20S/10S
-
DC winding resistance testing is regarded as another essential routine screening tool. It indicates problems such as loose, defective or incorrect connections, which cause enough transformer failures each year to be regarded as a failure category of its own.
-
Product
Transformer Winding Resistance Meters
RMO TW Series
-
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Product
Transformer Winding Resistance Testers / TRT ? 27
TRT-27 series
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 2.5A to 20A, Digital display of resistance and test current.
-
Product
Winding Resistance Meter
TRM 25
-
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
Product
Winding Resistance Test
20A DC booster
-
The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
-
Product
Winding Resistance Meter 15Amps, 2 Channels Rack
WR14R
-
Raytech Digital Winding Resistance meter WR14 R is the rack mount version of the WR14. They are designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Transformer Winding Resistance Meters
TWA Advanced Series
-
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Winding Resistance Meter 50Amps, 3 Channels Rack
WR50-13R
-
Raytech Digital Winding Resistance meter WR50-13R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
TRANSFORMER WINDING RESISTANCE METER
-
International Biological Laboratories
This Test set is suitable to measure winding resistance of transformers, single or 3-phase, star or delta connected upto several MVA.Two independent displays read the resistance of both primary & secondary windings simultaneously. However, primary or secondary winding can also be measured separately.
-
Product
Transformer Winding Resistance Meters
-
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
Product
Transformer Winding Resistance Meter
XWRM-10
-
The Motwane Manufacturing Company
The Motwane make XWRM-10 is a dual channel 10A rated, Transformer Winding Resistance Meter designed and developed aftere xtensive research on challenges and requirements of testing of various Transformer winding resistance. The instrument has One Current channel and two Resistance Channels. The instrument provides a large open circuit voltage of 42Volts, for fast charging of the highly inductive windings of transformers, to provide stable resistance values in minimum time. The XWRM-10 is intended to replace complex bridge set up with a single compact instrumentThe XWRM-10 is based on 4-wire measurement methodto measure low resistance accurately. The instrument iswell protected against inductive kickbacks offered by theinductive windings and gives stable reading on varioustypes of transformers.
-
Product
Winding Resistance Meter 50Amps, 2 Channels
WR50-12
-
Raytech Digital Winding Resistance meter WR50-12 is the enhanced version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Winding Resistance Tester with Demagnetisation Circuit
WRT-10D
-
The WRT-10D is a high performance winding resistance tester designed for power transformer and large motor applications. It is equipped with a bright LCD display, a rugged high quality cable set, a built-in printer, a full QWERTY keypad and a demagnetisation circuit.
-
Product
Winding Resistance Meter 50Amps, 3 Channels
WR50-13
-
Raytech Digital Winding Resistance meter WR50-13 is the enhanced version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
Product
Winding Resistance Meter 15Amps, 2 Channels
WR14
-
Raytech's Digital Winding Resistance meter WR14 is the battery powered version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy measurement of very low resistance of any inductive loads.
-
Product
AC Motor Tester
AIP892X series
-
Qingdao AIP Intelligent Instruments Co., Ltd
This product is suitable for electrical performance testing of all types of motors, such as home appliance motors (washing machines, air conditioners, fans, etc.), pump motors, stepper motors, etc. One-stop testing completes all set items, stable, fast, efficient and accurate, widely used by domestic and foreign enterprises.This AC motor tester test items: AC Hi-pot, insulation resistance, surge, DC winding resistance, no-load characteristics, low voltage start, locked rotor, rotation, PG characteristics.
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
STDETransformer Demagnetizer
STDE
-
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
Product
Primary Current Injection Test Set
T 2000
-
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
Passive Component ATS
-
Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Current Transformer Tester
CTT
-
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
Product
Electrical Measurement Equipment
-
Portable equipment designed for maintenance and commissioning of substations and power plants. Low resistance micro ohmmeters, digital timers, windings resistance, contact resistance, circuit breaker timing and motion, phase angle and frequency measurements.