Electrodes
-
Product
Starter Electrodes
-
Backed by our commitment to accurate and precise measurement, the OHAUS Starter Series of electrodes are designed to produce exact results time and time again.
-
Product
Cells and Electrodes
-
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
Product
Reference Electrodes
-
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
Product
Electrodes
-
Electrodes are offered in a wide variety of types. Spring electrodes are normally used in the inspection of pipes, although circular brush electrodes can also be used. Flat brush electrodes are used for flat surfaces. Brush materials can be of brass, steel or conductive neoprene construction. Internal electrodes are for testing internal pipe coatings.
-
Product
Counter Electrodes
-
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
Product
Water Analysis Meters & Electrodes
-
Ideal for Accurate Everyday Measurements in the Laboratory
-
Product
pH Electrodes
-
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
Product
Electrodes Sensor
6013
-
When selecting electrode sensors an important factor is to consider the specific characteristics of the liquid involved, the lengths required to obtain the desired control of levels, and the physical nature of the container.B/W Controls' line of electrodes has been developed to provide a practical, economical solution to almost every conceivable application and installation problem.Our electrode sensors are available in several varieties: solid rod (rigid), wire suspension, and standard gland plugs for high vibration applications. In addition, we offer custom options made per customer’s requirements.
-
Product
ESD LCD SURFACE RESISTIVITY METER (WITH 1 PAIR OF 5 POUND ELECTRODES)
-
The ESD LCD SURFACE RESISTIVITY METER provides everything necessary to test work surfaces using the procedure outlined in the EOS/ESD-S4.1 standard. This test kit makes testing surface resistance easy – simply place the weights attach the cables, switch to the correct voltage and press the button to read resistance directly on the meter. The meter incorporates parallel probes on the bottom of the unit which allows the user to make surface resistivity measurements. The parallel probes allow for quick and easy testing of a variety of surfaces and materials, without the use of the five pound electrodes
-
Product
Solder Paste Wetting Tester
SP-2
-
SP-2 is wettability testing machine forsolder paste, parts electrode and PC board,adopted SP-Tension-Method (Temperature Profile Method).
-
Product
Telurometer
AMRU-200 GPS
-
*The only meter on the market that implements all measurement methods:*Technical method of 2, 3 or 4 poles*Drive method (4/10μs, 8/20μs, 10/350μs).*Double-clamp method without the need for auxiliary electrodes.*Soil resistivity.
-
Product
Parallel Plate Dielectric Test Cell
LT-4203A
-
The LT-4203A Parallel Plate Dielectric Test Cell is designed for measuring the AC loss characteristics and permittivity of solid laminates and panels per ASTM Standard D150‑98, and implements the guarded electrode (three terminal) measurement preferred as the referee method.
-
Product
Rebar
-
Continuously monitors the coating line process as reinforcing bar runs through the RBRS dual-roller wet sponge electrodes unit. When a holiday is discovered, a red light flashes at the appropriate station on the detector unit for a visual indication, and the unit sends an eletrical output to a plug on the back of the unit. The MSRB signal output plugs drive any 120 Volt AC customer furnished horn, bell, recorder or computer.
-
Product
Miniature Concentric Ring Set
PRF-912B
-
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included
-
Product
Analog Tank Test Kit
4108
-
The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.
-
Product
Nexis GC-2030 BIDUFRGA
UFRGA Series
-
The Ultrafast RGA system utilizes the new Barrier Discharge Ionization Detector (BID) technology coupled with Nexis GC-2030 to create new system GC for ultrafast, high-sensitivity analysis. Since the electrode creating Helium plasma is totally isolated from the carrier gas, there is no chance to contaminate this electrode with a dirty sample. This enables long-term stability.
-
Product
Multi-Potentiostat
1000C
-
The model 1000B series is a computerized 8 channel potentiostat. The system contains a digital function generator, multiplexed data acquisition circuitry, and a multi-potentiostat that can work with eight independent cells or eight working electrodes in the same solution with common reference and counter electrodes. The potential control range is 10 V for all channels, which can be set at independent potentials or the same potential as the primary channel, so that they can sweep or step potentials together with the primary channel.
-
Product
BOMBARDING A.C. MILLIAMPERES METER
-
A Bombarding A.C. Milliamperes Meter is one of the four instruments essential for proper luminous tube processing. This instrument monitors the level of bombarder current in milliamperes that is generated by the bombarder, through the tube being processed. It is necessary to accurately monitor the current for the tubing and electrode sizes used to ensure that the right amount is applied at the appropriate time. To do otherwise may cause damage to the electrodes, fluorescent coating inside the tube and adversely affect the glass structure.
-
Product
ELIMINOSTAT
-
This AC voltage-applied static elimination device applies a high voltage to the needle-shaped electrode of the static elimination electrode and grounds the opposing electrode, generating a corona discharge and generating air ions to neutralize the charge on a charged object. This device is available in various models, including the HDC-AC model with a built-in power supply, AC models consisting of a static elimination electrode, a high-voltage power supply, and the high-voltage cable connecting them, DC models with a built-in DC power supply, and heat-resistant AC electrodes.
-
Product
Multi-probe for Ammonium and/or Nitrate
S470
-
S470 is a complete family of Ion selective electrodes (ISE) probes suitable for monitoring the performance of the ammonium ion (as NH4+ or NH4–N) and nitrate ion (as NO3– or NO3–N) in a liquid matrix.
-
Product
Ocean and River Instruments
RINKO W
-
Rinko W is an autonomously deployable data logger for long-term DO measurements. In order to protect the sensing foil against accumulating bio-fouling, the instrument has a mechanical wiper to sweep the optical window. The optical sensor does not have a membrane neither electrolytes, thus, it need less maintenance than electrode or galvanic sensors.
-
Product
ICP Plasma System
-
The AXIC IsoLok® Inductively Coupled Plasma (ICP) Load-Locked Processing System from AXIC, Inc. defines a new concept in Deep Reactive Ion Etch (DRIE) and low temperature-low damage Plasma Enhanced Chemical Vapor Deposition (ICP-PECVD) plasma processing. The system is based on a modular design starting with a universal chamber and cabinet unit with ICP etch or deposition bottom electrodes available for easy installation into the chamber unit combined with a load-lock. We are confident you will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma product in the market.
-
Product
Handheld Water Quality Meters
LAQUA DO210
-
Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsAuto log data; built-in memory can store up to 500 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmCasing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty
-
Product
Bluetooth® Enabled Nitrate & Temperature Pen
UltrapenX2™ PTBT6
-
*Nitrate Concentration (ppm N or ppm NO3-) or mV*1 and 2 Point Calibration Options*Proprietary ISE Sensor Design*Built-in Double Junction Reference Electrode*Compatible with EPA Approved Standard Method 4500-NO3-D*Live or Hold Mode – User Selectable*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Waterproof*Powered by One N Type Battery (Included)
-
Product
Soil Volumetric Water Content
HD3910…
-
The probes HD3910.1 (two electrodes) and HD3910.2 (three electrodes) measure the soil volumetric water content (VWC) by using a capacitive measurement principle which allows fast measurements in the field and with minimal invasiveness.
-
Product
Spring Clip Fixture
16092A
Test Fixture
Use this test fixture with parallel electrodes for impedance evaluation of both lead and SMD components.
-
Product
Field-installation Type pH Meter (Four-Wire Transmission)
HP-200
-
HP-200 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Premium Conductive Rubber Electrode
PRS-801-WV
-
- Ideal when qualifying or cerftifying material & installation- Each electrode has a resistance of less than 10 ohms- Flatness is measured and delivered within Prostat's specs- Capped to protect the pad against deformation- In accordance with ANSI/ESD S4.1 amd ANSI/ESD S7.1- NIST traceable ceritificate provided for each premium electrode
-
Product
Model LGF: Gypsum Moisture Meter
MRC006522
-
Stainless steel flat plate electrode. Excellent for testing Gypsum Wallboard as it moves or in stacks. Measures moisture in the Gypsum plasterboard 1/4 inch to 3/4 inch thick. Can also check moisture distribution pattern and length or width.
-
Product
Radiometer Analytical Probes
-