Electrodes
-
product
Charge Meter
NK-1001A/NK-1002A
Probe-type charge meter that can easily measure the amount of discharge charge that causes static electricity destruction in the manufacturing, inspection, and assembly processes of electronic devices.Many ESD phenomena that impair electronic devices are represented by the CDM ( Device Charging Model). The CDM is a model that represents a phenomenon in which a high peak current flows at high speed when the device itself is charged and its external electrode is grounded. The coulomb meter measures the amount of discharge charge, which is the integral value of the current, with high accuracy.
-
product
Industrial pH Meter (Four-Wire Analyzer)
HP-200-K
One-touch calibration function Realizes gentle measurement by combination with lead-free ORP electrode
-
product
Water Analysis Meters & Electrodes
Ideal for Accurate Everyday Measurements in the Laboratory
-
product
Spark Testers
Range of portable and hand-held AC spark testers, kits, accessories and electrodes which are all specifically configured to suit a range of test applications.
-
product
Semiconductor Packaging System
Inspects the quality of finished cells by measuring the gap between the battery electrode laminate and aluminum can.
-
product
9VT Neon Tube Tester
West Coast Custom Designs, LLC
When the antenna and/or the Disc are touched to the tubing wall or electrode wires, the tester will cause the viable tubing to illuminate.
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Charge Plate Monitor
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
product
Dielectric Material Test Fixture
16453A
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.
-
product
Parallel systems
Did you know you can couple several Gill AC, Gill 12 and Weld Testers together or any combination of Gill AC, Gill 12 or Weld Tester, to give you a parallel logging multiple Potentiostat / Galvanostat / ZRA / FRA system, capable of recording from each working electrode at up to 60 readings per second. Coupling several Gill ACs or Gill 12s together gives the added abilities of the Weld tester and the ability to perform fast sweeps. Using our latest software, it has never been easier to couple instruments together to provide a Parallel System. In fact up to 32 instruments can be controlled at the same time. These instruments can either have individually enclosures or be rack mounted.
-
product
Cell Production
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
product
Solid Electrode Spectrochemical Cell
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
product
Rotating Ring Disk Electrode
RRDE-3A
RRDE-3A is a constant rotation system for use in hydrodynamic modulation rotating ring disk electrochemistry. A 7 mm diameter electrode with short stainless steel shaft provides for a miniature and concentric circle electrode system that is capable for highly accurate rotation and modulation even at radial modulation rates or wave forms.
-
product
Earth Resistance Testers
Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster.
-
product
Ion/pH/mV Meter with Single Junction pH Electrode
Ion 6+
Direct Ion Concentration for use with most mono- or di-valent Ion Selective Electrodes (ISE) :: mV measurement mode allows you to check performance and calibration of your ISE
-
product
Single Channel Potentiostats
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
product
pHTestr® 50 Waterproof Pocket pH Tester,
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
product
Gamma Detectors
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
product
SpectrOil M/F-W Fuel Analyzer
SpectrOil M
The SpectrOil M/F-W is a compact, rugged and easy to use fuel analysis spectrometer. It is designed specifically for the analysis of ash-forming contaminants in fuel such as sodium, potassium and vanadium that cause corrosion or deposits at turbine operating temperatures. It measures trace quantities of dissolved or suspended contaminant particles in a fuel sample using the time-tested and reliable rotating disc electrode (RDE) technique.
-
product
Domestic Direct Reading Spectrometer
CS-8610
Wuxi Jinyibo Instrument Technology Co., Ltd.
1. Convenient, practical and reliable: unique combustion device, equipped with infrared detection system, direct connection, remote control operation.2 , patented burner design (using utility model patent technology)The burner electrode upgrading system adopts a spring structure, the electrode adjustment is convenient, and the double sealing ring guarantee the pressure balance in the furnace cavity without tempering.3 , to ensure accurate measurement results◆Using low-noise, high-sensitivity, high-stability pyroelectric infrared detectors.◆Specially-made new platinum infrared light source, continuous heating and high spectral efficiency.The modular design of the whole machine, the electronic circuit is highly integrated, which improves the reliability of the instrument.◆Industrial-grade integrated linear module power supply, stable output, no fault.◆The infrared detection part and the combustion furnace are connected by optical fiber, and cooperate with multi-level concealed isolation circuit to completely eliminate arc interference.◆Double filter device to reduce the impact of dust on the analysis results.4 , electronic balance is not quantitative sample: you can choose different brands of electronic balance, automatic online, to achieve non-quantitative weighing.
-
product
Microscopic Four-Point Probes
M4PP
CAPRES M4PP Microscopic Four-Point Probes have an electrode pitch three orders of magnitude smaller than conventional four-point probes, and are fabricated using silicon micro-fabrication technology.
-
product
Electrodes Sensor
6013
When selecting electrode sensors an important factor is to consider the specific characteristics of the liquid involved, the lengths required to obtain the desired control of levels, and the physical nature of the container.B/W Controls' line of electrodes has been developed to provide a practical, economical solution to almost every conceivable application and installation problem.Our electrode sensors are available in several varieties: solid rod (rigid), wire suspension, and standard gland plugs for high vibration applications. In addition, we offer custom options made per customer’s requirements.
-
product
Corrosion Analysis
Profometer Corrosion
The Profometer Corrosion is the most versatile corrosion analysis solution in the market based on the half-cell method. Proceq’s unique wheel electrodes allow the fastest and most efficient on-site testing. As direct successor to the Canin, it is compatible with existing Canin and most third party electrodes.
-
product
Meter with "3-in-1" pH/Temperature Combi Electrode
pH 6+
Multi-Point Calibration (up to 3 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
product
Arc Ingintion Tester
The product is designed to carry out Arc Ignition Test as per IS/IEC 60947-1 Clause 8.2.1.1.2 (material used for electrical products). The adjustable current source is 230V AC @ 33A. The load is adjusted to get 32.5A at 0.5 power factor. Included on control unit are Digital Voltmeter, Digital Ammeter, Digital Power Factor Meter and Micro Controller based programmable Sequence Timer with LCD display for display & setting. The arrangement is made to mount the test piece with electrodes as per the specification given in the standard.
-
product
Spring Clip Fixture
16092A
Use this test fixture with parallel electrodes for impedance evaluation of both lead and SMD components.
-
product
Geophysics
ELETOM
ELETOM is a software that performs complete 2D inversion (and not the simple iterative deconvolution of the pseudo-sections) of surface electrical surveys with any measurement array (Wenner, dipole-dipole, pole-dipole, pole-pole, user defined arrays, mixed arrays) with a maximum of 64 electrode positions that can be added by the user as required.
-
product
3D inversion geophysical software for Resistivity and Induced Polarization Data
RES3DINV
This program is designed to invert data collected with a rectangular grid of electrodes. The arrays supported include the pole-pole, pole-dipole, inline dipole-dipole, equatorial dipole-dipole and Wenner-Schlumberger. The RES3DINV program uses the smoothness-constrained least-squares inversion technique to produce a 3D model of the subsurface from the apparent resistivity data alone.
-
product
Dielectric Loss Tangent Testing Instruments
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.