-
Product
FieldFox Handheld Microwave Spectrum Analyzer, 18 GHz
N9937B
-
A lightweight, durable, microwave spectrum analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more.
-
Product
Modulation Distortion For E5081A Up To 20 GHz
S960704B
-
The Keysight S960704B modulation distortion software application enables fast and accurate active device modulation distortion characterization under modulated signal conditions up to 20 GHz. The wide dynamic range and vector error correction of the ENA-X yield an extremely low residual EVM of the test setup, delivering a complete picture of your device’s signal distortion performance without test system interference. S960704B software measures EVM, NPR, ACPR, and decomposes linear and nonlinear signals by spectrally correlating input and output spectrum without needing to demodulate. Integration with the ENA-X measurement flexibility enables quick modulated signal distortion measurements along with traditional VNA tests.
-
Product
Film Thickness Measurement
-
Film thickness measurement can be measured using a number of different techniques depending on the thickness and number of layers. In its simplest form a simple measurement can be made of a single layer with a reflective lower surface using interference fringes. For more complex materials with multiple layers interference measurement is still made, but the mathematical deconvolution becomes increasingly important as does the refractive index of each layer.
-
Product
Current Caliper
KH23101
-
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.
-
Product
Prostat Contact Voltmeter
CVM-780
-
The CVM-780 contact voltmeter combines the ease of use of a digital voltmeter with the high impedance and low capacitance of a true electrostatic voltmeter, in a small, portable package.It reads the actual voltage, without interference from the electrostatic field strength. The ceramic tips of the probe allow precise measurement of values.Measurement of voltages up to 500 VDC.
-
Product
High Voltage Ammeter
Ampstik®+
-
Use the Ampstik+ to safely take accurate current measurements when performing high voltage live-line load checks for balancing, switching, or breaking load. This high voltage ammeter measures in every electric utility setting with a linear current sensor to accurately measure .5A to 5000A, while in voltage environments up to 500kV. The opening of the amp sensor is electronically closed, while external currents are electronically rejected. This design enables the user to measure an individual conductor within close proximity to adjacent conductors without interference errors.
-
Product
Total Nitrogen Unit For TOC-L Series
TNM-L
-
Perform simultaneous TOC and TN measurements. *720 °C catalytic thermal decomposition/chemiluminescence methods are adopted for TN measurement. There is no interference from metallic ions or bromine in sea water.*Measurements over a wide range with a detection limit of 5 μg/L for TOC-LCH to an upper limit of 10,000 mg/L.
-
Product
Optical Oxygen Sensors
-
The analyzer is suitable for direct field installation (NEMA 4X) in hazardous area (Class I, Division 2). The optical fiber sensor platform allows small inline sensors to be installed into sample tubing lines (1/4”), flow cells using NPT fittings, or directly into tanks or process lines using our retractable “hot tap” sensor design. BOS optical oxygen sensors are impervious to typical O2 poisons (H2S) and interferences (combustibles, magnetic, CO2 and H2) with high accuracy and long-term stability measurements without the need for complex or advanced sample conditioning systems. The threaded version of the optical sensor has optional Dual Seal (ANSI/ISA 12.27.01) classification for high pressure applications up to 1200 PSIG (82.7 BAR).
-
Product
Flash SATA Disk/mSATA Mini SATA 3 SLC, MLC
FSA 301 Series
-
*SATA III (6.0Gb/s) interface*Capacity: SLC 1 GB to 32 GB, MLC 4 GB to 64 GB*iSMART disk health monitoring*Intelligent error recovery system*Write protection security*Anti-vibration mechanical design*Excellent data transfer speed*Zero mechanical interference*JEDEC standard MO300B dimension
-
Product
Ground EMI Filters
-
High-frequency signals on ground is never good news - it interferes with normal operation of equipment and creates electrical overstress (EOS). However it is easy to block propagation of EMI on ground by installing highly-effective ground EMI filtes in ground lines. Our unique patent-pending ground EMI filters provide very low impedance for DC and mains' power while effectively blocking propagation of high-frequency currents throughout facility or equipment ground. Ground filters meet safety standards, as well as ANSI/ESD S6.1 and ANSI/ESD S20.20.
-
Product
Quantum Accelerometer
-
A quantum accelerometer uses atom interferometry to measure accelerations along a horizontal axis. Quantum accelerometers are able to achieve a combination of sensitivity and stability by exploiting quantum interference. As such, they will be critical components of a quantum inertial navigation unit, which will offer satellite-free navigation with unparalleled long-term accuracy. A phase locked SolsTiS system underpins this setup and provides the extremely low phase noise required to make high sensitivity measurements and dynamic frequency tunability to address multiple atomic transitions.
-
Product
Modulation Distortion Up To 50 GHz
S930705B
-
S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
PCIe Gen3 X16 Bus Expansion Via Dual X8 OCuLink
PCI125
-
The PCI125 is VadaTech’s 4th generation PCIe expansion module based on the PCI-SIG specification. The Module has a Retimer/Conditioner to improve signal integrity for enhancing system performance and reliability across long cables. It removes both random and deterministic jitter from the input signals eliminating inter-symbol interference and resets the output jitter budget. It supports the full 16 lanes.
-
Product
Miller 400D
44550
-
No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)
-
Product
8-Ch SPST 12A-250VAC 24VDC Mux
H62004700
-
This module is ideal for switching up to 12A. Composed by eight relays organized in two trees of four with two relays (One in each tree) with NC contact available. The module is shielded in order to reduce the radiated interference in high current switchings.
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
Product
VS200/300 & PC-VS Systems
-
For Measuring * Impact Velocity - Both Pre and Post * Impact Energy & Loss * Materials Restitution Non-Contacting Optical Sensor:Does not interfere with test machine, compensates for machine friction and air drag.
-
Product
Photolytic True NO2/NO/NOx Analyzer
Model T200P
-
Teledyne Advanced Pollution Instrumentation
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
-
Product
Programmable AC Power Source
LSP-500VAC
-
• Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);
-
Product
EMI Test Receiver
SER
-
Saluki SER series EMI receivers comply with CISPR 16-1-1 standard, integrated CISPR-AVG, CISPR-RMS, QPK detectors, and electromagnetic interference measurement. According to CISPR, EN, FCC and MIL standards, which is suitable for EMI testing in home appliances, lighting, automotive electronics, medical, and other industries. Combined with ETR PC measurement software and a wealth of test options, accurate automated testing is possible. The whole system is equipped with a spectrum analysis module and a tracking signal generator to meet the testing needs of users in different fields.
-
Product
Lightning Surge Generator
STT-LSG-7K16A
-
Beijing KeHuan Century EMC Technology Co,.LTD
The lightning surge generator STT-LSG-7K16A provides a common basis for evaluating the performance of equipment power lines and internal connecting lines when they are subjected to high-energy transient interference from switching and natural lightning strikes. The performance meets the requirements of IEC61000- 4-5 and GB/T17626.5 standards.
-
Product
FieldFox Handheld Microwave Spectrum Analyzer, 50 GHz
N9962A
-
9 kHz to 50 GHz frequency range Expand capabilities with optional tracking generator, interference analyzer, built-in power meter, and more Make accurate spectrum analyzer measurements ( 0.5 dB) without needing warm-up Locate interfering signals using the intuitive spectrogram display and recording capability Easily measure average and pulse power with a USB power sensor, pulse measurements with time gating Lightest microwave handheld spectrum analyzer at only 7.1 lb. (3.2 kg)
-
Product
Heuristics Testing Browser Add-On
-
Convenient access to common boundaries and edge cases for exploratory testing. Tiny overhead per page (<1k), no 3rd party library dependencies, completely passive, so it does not interfere with your web app execution in any way. Works on input fields, text areas, content editable DIVs. Load your own config files. Opensource, so you can easily extend it with your config.
-
Product
Quantum Gravimeter
-
The quantum gravimeter, the first commercial device of its kind in the UK, uses quantum interference of matter waves to measure the local value of gravitational acceleration, or ‘g’, with very high precision. Objects with different mass cause small fluctuations in the value of g measured on the surface of the Earth. The quantum gravimeter can be used to sense these objects hidden under the surface in a non-intrusive manner.
-
Product
Signal Conditioner
ClipX
-
Fast and digital signal conditioning for force sensors, load cells, torque sensors, pressure transducers, as well as temperature and standardized signals (current/voltage). Guaranteed measurement accuracy, even in harsh industrial environments with electrical interferences.
-
Product
Digital TV Spectrum Analyzer
DS2831
-
Fast Spectrum Analyzer: detect and troubleshoot ingress with exceptional sensitivity of -60dBmV @ 300KHz RBW. Color-Coded Persistence Test: find transient noise hiding under upstream bursty signaling, without disrupting service. MER Measurement: up to 47 dB MER with 48 hours of statistical recording with 1 second resolution. Analog TV and SC-QAM: troubleshoot typical analog interference and distortions as well as SC-QAM performance. Time-Domain EVS Measurements: uncover interference from LTE signals under downstream QAM carriers with no service interruptions.Characterize OFDM carrier performance and DOCSIS 3.1 cable modem performance.
-
Product
Real-time Spectrum Analyzers
SSA3000X-R
-
The SIGLENT SSA3000X-R real-time spectrum analyzers are powerful and flexible tools for complex RF signal monitor and analysis. With a capability of 40 MHz analysis bandwidth and 7.2 µs 100% POI, the analyzer can provide multi-dimensions data displays, advanced triggering, and RF data capturing, to solve modern RF spectrum challenges, like hopping frequency, conflict channel, spectrum interference, etc. They also provide standard tracking generator for network analysis, optional wideband digital modulation analysis, and EMI pre-compliance test. Applications include broadcast monitoring/evaluation, cellular site, IoT, WiFi, Bluetooth surveying, research and development, education, production, and maintenance.
-
Product
Multiplexer 2:1 With De-Emphasis 32 Gb/s
M8062A
-
R&D and test engineers who need to characterize serial interfaces of up to 32.0 Gb/s can use the M8061A 2:1 Multiplexer with optional de-emphasis to extend the rate of J-BERT M8020A and J-BERT N4903B pattern generator. For the most accurate receiver characterization results, the M8061A provides four calibrated de-emphasis taps, which can be extended to eight taps, built-in superposition of level interference and Clock/2 jitter injection. The M8061A is a 2-slot AXIe module that can be controlled via USB from the user interface of J-BERT M8020A as well as N4903B.
-
Product
PXIe-5667, 3.6 GHz PXI Vector Signal Analyzer
782366-03
-
PXIe, 3.6 GHz PXI Vector Signal Analyzer - The PXIe‑5667 is optimized for spectrum monitoring applications such as radio monitoring, interference detection, spectrum regulation, and related applications in line with ITU recommendations. It features real-time signal analysis and advanced signal processing using the capabilities of the built-in FPGA. Additionally, the PXIe‑5667 includes options for various frequency ranges and instantaneous bandwidth.
-
Product
E84 Recorder
-
GCI's industry leading E84 Recorder is used by FABs and OEMs worldwide to locate and resolve E84 handshake issues due to signal drops and external interference. It non-intrusively captures the states of all E84 signals during live material handoffs and records them to the connected PC's hard drive. Short- and long-term recording modes are available using E84 Analysis, GCI's industry leading diagnostic software.





























