Product
Low Voltage DC / Battery Powered High Voltage Amplifiers
WMA-005 And WMA-005LF
-
The Falco Systems WMA-005 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 3mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-005LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.1mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.
-
Product
8-Ch SPST 12A-250VAC 24VDC Multiplexer with CAN
H620047C2
-
This module is ideal for switching up to 12A. Composed by eight relays organized in two trees of four with two relays with NC contact available. The module is shielded in order to reduce the radiated interference in high current switchings.
-
Product
USB 2.0 Interface Module
-
USB 2.0 modules for RF Test Enclosures eliminate conducted and radiated interference while keeping data and power signals for the USB 2.0 link untouched.
-
Product
Fast Tuned Notch Filter
ES005 & ES006
-
Teledyne Defence & Space’s (TDS) range of Fast Tuned Notch Filters (FTNF) have been designed to protect Electronic Support Measures (ESM) receivers from high duty cycle, frequency agile interference produced by on board (or cohort) combat radar systems. ESM sensors often need protection from high power nearby radars, and such signals can reduce receiver dynamic range.
-
Product
UltraTEV Plus
-
The UltraTEV Plus is the latest innovation being introduced to the award winning UltraTEV range. This easy to use instrument incorporates additional sensing capabilities and real time advances analytical features enabling you to distinguish between true PD, noise and other interference allowing you to make better decisions while saving time and money and enhance the safety of your staff and your network.
-
Product
CRPA Test System
-
The Spirent CRPA Test System is a development of Spirent’s GSS9000 Series platform for testing Controlled Reception Pattern Antenna (CRPA) systems with a separate RF output per antenna element. The CRPA Test System generates both GNSS and interference signals. Users can control multiple antenna elements. Null-steering and space/time adaptive CRPA testing are both supported by this comprehensive wavefront approach.
-
Product
Spectral Phase Measurement
Avoca SPIDER System
-
Spectral phase interferometry for direct electric-field reconstruction (SPIDER) is one technique that can recover the spectral phase of an input pulse, without needing any reference pulse. SPIDER interferes two pulses which areseparated in time and in frequency, and the resultantinterferogram is read by a spectrometer.
-
Product
Electromagnetic Interference Test
-
Electromagnetic interference (also known as radio frequency interference) tests are used to determine the electromagnetic characteristics of electrical, electronic, and electro-mechanical equipment. Electromagnetic interference, both radiated or conducted, can affect the performance of equipment. Electromagnetic interference tests are specified as follows: conducted emission, radiated emission, conducted susceptibility, and radiated susceptibility.
-
Product
Network Interface Controller
SPIDAR®
-
User interface and data acquisition embedded on the NIC:1. Any device with Wi-Fi can be used to change settings or view data collection2. No data collection interruption or data loss occurs if connection to PC or device is interrupted. No reduction in speed compared to running a single system. Daisy-chain NICs to deploy any number of GPR systems simultaneously; build Multi-frequency systems or Multi-channel Array systems Advanced timing control to ensure no interference between GPR systems
-
Product
Aerospace
-
Radiometrics Midwest Corporation
Working with the Radio Technical Commission for Aeronautics, Radiometrics staff has not only been involved with EMC testing of aircraft and aircraft components, but has also been involved with development of the RTCA/DO160 "Environmental Conditions" standard and RTCA/DO-199 investigation for "Potential Interference to Aircraft Electronic Equipment from Devices Carried Aboard".
-
Product
Trace-Level UV Fluorescence SO2 Analyzer
Model T100U
-
Teledyne Advanced Pollution Instrumentation
The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.
-
Product
Data Acquisition & Signal Conditioners
-
Electro Standards Laboratories
Electro Standards Laboratories offers instrumentation and signal processors in both encased form factors or board-only versions suitable for embedded sensor applications. Features ability to collocate with sensor and provide immediate digitization and signal processing in order to minimize ambient interference on sensitive sensors and to seamlessly integrate into networked sensor architectures.
-
Product
EMI Receiver
KH3939
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH3939 type EMI test receiver interference test receiver is fully automatic, is EMI major tool for testing. The frequency range of the KH3939 receiver is from 9kHz to 300MHz , which satisfies the power line disturbance power test. After configuring the artificial power network, the power terminal disturbance voltage test can be carried out. The machine has fast test speed, strong maneuverability, stable performance, Advantages such as convenient test data processing. The KH3939 receiver uses a USB interface for data transmission, and supports USBinterface peripheral devices such as printers, mice, keyboards, etc. The machine is equipped with a high-speed and large-capacity hard disk, which stores a variety of external device data, and supports plug and play. External test equipment. The software is self-developed by our company, using windows as the carrier, users who are familiar with the operation of windows can quickly get started. The machine can independently carry out test work without additional control equipment for control operations, which fundamentally solves the problem of interference sources. The measurement results can be input to the hard disk in the receiver or stored in a floppy disk through a floppy drive or printed out directly or savedusing a USB storage device. The detailed measurement report can be printed directly according to user needs without additional editing.
-
Product
PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit
APCI-3501-4
-
4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V
-
Product
15 Amp 120 VAC Filter and Surge Arrestor
AS-AC15
-
- 15 amp 120VAC quad outlet for high power devices- Resettable circuit breaker protection, easy to use and reset- I EA standard input plug and #14 GA AC line cord for USA - standard interface- MOV surge arrestors included - for even more protection- High level of common mode and differential mode filtering digital noise and RF filtering eliminates- digital artifacts and RF interference - See chart- Front Panel Neon Blue AC ON indicator - just plain cool to look at, not too bright!- Double shielded box inside - for optimum filtering operation- Size 6W X 4H X 4 3/4 D in inches approx 3 lbs
-
Product
DUMMY BLOCK
STAG 10
-
Ideal requirements of release agent between billet and dummy block:Optimal adhesion to the substrate, Optimal anti-soldering power, No hazardous fumes/vapors development during use, Non-flammable at the effective temperature, No build-up, no interferences on run out table.
-
Product
Proprietary LPWAN IoT Wireless Self-Powered CT Node
WISE-2210
-
Proprietary LPWAN (Sub-G) wireless technology with Less interference with high penetration rate capabilityPower over AI channel design, no extra power wired installation neededHigh efficiency power charger design via CT (AC 0~100mA)Max. 3AI channels for CT nodeCompact design, suitable for plug and play applications.
-
Product
Ethernet Interface Module
-
Ethernet modules for RF Test Enclosures eliminate conducted and radiated interference while keeping data and power signals for the Ethernet link untouched.
-
Product
Tunable Diode Laser
-
Tunable diode laser absorption spectroscopy (TDLAS) is a fast, accurate, non-contact gas analysis technique that responds quickly to changing analyte concentrations. It is a proven technology free of interferences from other sample stream components.
-
Product
Near-Field Probes 100 kHz up to 50 MHz
LF1 set
-
The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.
-
Product
GT6000 Mobilis
-
The GT6000 Mobilis is EN15267-4 QAL1 certified (MCERTS) Fourier Transform Infrared (FTIR) portable analyzer, specifically designed for those who aim high. It enables you to concentrate on the task at hand, without interferences from hard to use, time-consuming and unreliable tools. Sounds good, right? Do you need extreme portability, robustness and want to save time? Or reliable instrument, powerful analysis tools and rapid response times? GT6000 Mobilis provides this all and more. Read on to get the full picture of this solution.
-
Product
ISN / T-Networks
-
Is used to measure the asymmetrical interference voltage on symmetrical data or telecommunication lines.
-
Product
Signal Analysis
Synchronous Accumulation (Order Analysis)
-
Order analysis is one of the most convenient and efficient methods for diagnostics and balancing of rotating mechanisms and transmission gears. With an RPM sensor and a vibration sensor, it is possible to study the time characteristics of gear vibration signals. It is a well-known fact that a signal from a vibration sensor is affected by signals from other sources. To tune out from the disturbing signals, the synchronous signal accumulation method is used. For each shaft rotation, the RPM sensor provides a rotation mark. This signal serves as a triggering strobe for the vibration sensor signal sweeping. The obtained signal sweeps are combined. All the sources of the signals related to the shaft frequency (frequency of rotation) are accumulated and increased in the accumulator linearly proportionally to the N number of rotations. All other signals that are not correlated with the shaft frequency are accumulated proportionally to N1/2 and in case of a greater number of averagings, the useful signal exceeds the interference level.
-
Product
Material Compatibility Test System (MCTS)
-
Automotive squeaks occur when materials in contact rub against one another causing annoying noises from friction-induced stick-slips. Automotive itches are a special category of squeaks that can develop when rubber or plastic rubs against glass or paint. The MB Dynamics Material Compatibility Squeak & Itch Test System (MCTS) is designed and manufactured to subject contacting pairs of materials and actual vehicle parts to precisely controlled interference & motion under in-vehicle environmental conditions in order to acquire, monitor, analyze and report friction and acoustic characteristics with the objective to:
-
Product
EMC Testing
-
Does your product send or receive electromagnetic data? This can be analyzed using various tests. We investigate the interference immunity and emitted interference of simple electrical devices and complex machinery. Our EMC measurements and tests conducted in accordance with standards recognize all activity in the electromagnetic field and ascertain how immune to interference a piece of equipment is. We will also offer guidance on optimizing the product in terms of its EMC properties during the development phase.
-
Product
Near Field Probes 1GHz - 10 GHz
SX set
-
The SX1 set consists of 3 passive near field probes for making measurements in the development phase of E-field and magnetic field with a high clock frequency in the range from 1 GHz to 10 GHz. The probe heads of the set SX allow for measurements close to electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors, to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through trained use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
Product
Immunity Development System
-
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
Product
Interferometers
-
An instrument in which the interference of two beams of light is employed to make precise measurements.
-
Product
Audio Line Drivers and Receivers
-
Analog Devices audio line driver and receiver solutions feature differential-output buffer amplifiers and differential input buffer amplifiers to support a wide range of applications. By using low noise thermally matched thin film resistors and high slew rate amplifiers, these parts maintain the sonic quality of audio systems by eliminating power line hum, RF interference, voltage drops, and other externally generated noise commonly encountered with long audio cable runs. Applications involving this product portfolio include ADC drivers, high performance audio, sine/cosine encoders, and other professional and consumer uses.
-
Product
Paramagnetic O2 Analyzer Optional CO2 Sensor
Model T802
-
Teledyne Advanced Pollution Instrumentation
The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.