High Speed Data Recorders
See Also: Recorders, XY Recorders, Chart Recorders, Fault Recorders, Disturbance Recorders, Event Recorders, Transient Recorders, Temperature Recorders, Data Recorders
-
Product
Cable Diagnosis System
Baseline 9400 TDR/ICE
-
K&S Engineering and Scientific Ltd
BASELINE 9400 TDR/ICE - the unique cable diagnostic system: - A state-of-the art cable fault locating instrument containing a high speed data recorder, capable of capturing and evaluating 40 million samples of electrical data per second, while also featuring amplifiers, attenuators and an adjustable pulse generator.
-
Product
High Speed Data Recording
-
We are a premiere manufacturer of deployable appliances designed for high performance data recording, based on the latest Intel, AMD and data storage technologies. Our systems give the highest level of compute and network capability in compact form factors to fit your performance requirements and working conditions.
-
Product
Data recorder
Cobra
-
The Cobra High Speed Recorder is a unique solution for high speed data recording and playback at a rate of up to 20 GB/s (160 Gbps). The system utilizes the PXI Express architecture to provide a modular, flexible solution that can be customized to nearly any requirement. The main recording engine, Cobra, is a PXIe board with high speed RAM and a high performance Xilinx FPGA. This board manages the data movement to and from storage devices and also provides optical fiber channels for high speed data input or output. The Cobra board can be used alone or in concert with additional Cobra boards.
-
Product
SHC68-68-RDIO, 68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable, 1m
191667-01
High Speed Digital Cable
68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Digital Cable 1m
-
Product
SHC68-C68-RDIO2, 68-Pin VHDCI Male to 68-Pin VHDCI Male, 80 MHz, Shielded Digital Cable, 1m
156166-01
High Speed Digital Cable
SHC68-C68-RDIO2 Shielded R Series High Speed Digital Male VHDCI Cable, 1m
-
Product
400 MHz High Voltage Differential Probe
DP0001A
High Current Probe
The DP0001A is a 400 MHz high voltage differential probe with 2 kV mains isolated or 1 kV CAT III rating designed for making accurate high-voltage power measurements required for testing today’s WBG power devices, power converters or motor drives.
-
Product
64-Channel 1MSa/s USB Modular Multifunction Data Acquisition
U2331A
Data Acquisition Module
The U2331A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2331A to simulate simultaneous analog input acquisition.
-
Product
Relay Output & Digital Input Module
ND-6060
Data Acquisition Module
- 4-CH relay outputs- Output Type: 2 form C and 2 form A- Contact Rating: AC: 0.5 A / 125 V; DC: 1 A / 30 V, 0.3 A / 110 V- Common External Voltage: 24 V- Input Type: switch or transistor
-
Product
3 Function Slot MOSA Nano Data Concentrator Unit (DCU)
NIU3A-DCU-01
Data Concentrator Unit
NIU3A-RDC-01 is a Modular Open Systems Approach (MOSA) Data Concentrator with low power high performance ARM Cortex -A53 processing. 8 GB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet.
-
Product
Modular and Scalable Multifunction Switch/Measure Units
EX1200 Series
Data Acquisition Module
The EX1200 product family is a modular and scalable series of multifunction switch/measure units that can be configured to address a variety of applications in the mechanical data acquisition and electronic test environments.
-
Product
Rogowski AC Current Probe,30 MHz, 600 A
N7041A
High Current Probe
The Keysight N7041A Rogowski coil current probe measures AC currents up to 600 A, with bandwidth ranging from 12 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
4-CH 24-Bit Universal Input USB DAQ Modules (OEM Version Available)
USB-2401
Data Acquisition Module
The USB-2401 is a 24-bit, 4-channel simultaneous-sampling universal input USB DAQ modules featuring built-in signal conditioning circuitry, providing direct measurement of commonly used sensors including current output transducers, thermocouple, RTD, load cell, strain gauge, and others. Individual channels can be programmed to measure different signal types. The USB-powered USB-2401 is equipped with removable screw-down terminals for easy device connectivity, and the included multi-functional stand fully supports desktop, rail, or wall mounting.
-
Product
16-CH 16-Bit 250 kS/s Low-Cost Multi-Function DAQ PCI Express Cards
DAQe-2213/2214
Data Acquisition Module
ADLINK DAQe-2213/2214 can sample up to 16 AI channels with different gain settings and scan sequences. It makes them ideal for dealing with analog signals with various input ranges and sampling speeds. These devices also offer differential mode for 8 AI channels in order to achieve maximum noise elimination.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Godzilla High Current Probes, 150 Amp
HC500
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
High-Voltage Differential Probe, 25 MHz
N2791A
High Current Probe
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
Product
4x 3U OpenVPX MOSA Data Concentrator Unit
SIU34-DCUVARM-01
Data Concentrator Unit
SIU34-DCUVARM-01 is a Modular Open Systems Approach (MOSA) DO-178C & DO-254 Certifiable Data Concentrator Unit (DCU) with low power high performance OpenVPX Xilinx UltraScale+ SBC with Quad Core ARM Cortex -A53, 8 GB DDR4 SDRAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet, USB 3.0, FIPS-140-3 Level 3 Cyber Security, and Single Event Upset support.
-
Product
HPC High Current Probes, 100 – 187 mil (2.54 – 4.75 mm)
HPC
High Current Probe
100 – 187 mil (2.54 – 4.75 mm)
-
Product
Data Acquisition and Control System
DAQ 7000
Data Acquisition System
data acquisition and control system that provides connectivity, signal conditioning and modular I/O for variety of sensors or signals, and it is an ideal DAQ for field deployment.
-
Product
15-CH Isolated Digital Input Module
ND-6054
Data Acquisition Module
- Channels: 15- Isolation Voltage: 5000 VRMS- Switching Level: with 24 V common power. Low (0): 22 V min.; High (1): 0-22 V- Programmable input polarity
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
16-CH 16-Bit 250 KS/s Simultaneous Sampling DAQ Cards
PXI-2022
Data Acquisition Module
ADLINK"s PXI-2022 is a simultaneous-sampling multi-function DAQ card to meet a wide range of application requirements for PXI bus computers. The device can simultaneously sample 16 AI channels with differential input configurations in order to achieve maximum noise elimination.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
16-CH 12/16-Bit 100 kS/s Low-Cost Multi-Function DAQ Cards
PCI-9111 Series
Data Acquisition Module
ADLINK PCI-9111 series are 16-CH, 100 kS/s low cost multi-function DAQ card. The PCI-9111 series feature flexible configurations on analog inputs. A RC filter is implemented on each A/D input channel for user to attenuate or filter input signal. The PCI-9111 series provide analog inputs with 5 programmable input ranges for bipolar inputs. The PCI-9111 series also support automatic analog input scanning. PCI-9111DG provides 12-bit A/D resolution while PCI-9111HR provides 16-bit A/D resolution. The PCI-9111 series also feature 1-CH 12-bit analog output, 16-CH TTL digital inputs and 16-CH TTL digital outputs. ADLINK PCI-9111 series deliver cost-effective and reliable data acquisition capabilities, and is ideal for a broad variety of applications.
-
Product
PXI Express Data Acquisition Platform
Data Acquisition Module
PXI Express is the fastest data acquisition platform currently available with unmatched bandwidths in excess of 1 GB/s and latencies less than 1 µs. This makes PXI Express-based data acquisition systems ideal for data intensive applications like high-speed digitization, signal-generation, and communication interfaces where high sample rates and channel counts could choke other interfaces.
-
Product
8-CH Isolated Digital Input Module
ND-6052
Data Acquisition Module
- Channels: 8 DI. 6 fully independent isolated; 2 isolated with common ground- Isolated Voltage: 5000 VRMS- Programmable input polarity
-
Product
Intelligent 16 Bit Data Acquisition
CPCI-AD16
Data Acquisition Module
The CPCI-AD16 module provides a 3U high performance data acquisition subsystem. The Local DSP can be used to simply move data samples to the CPCI bus or can provide processing functions such as limit checking, FFT’s, digitalfiltering, etc. Application software can be downloaded to the DSP via the CPCI interface. Instrumentation amplifiers provide over-voltage protection, gain and filtering on a per channel basis. Internal scan and trigger clocks are derived from either the CPCI bus clock or the local DSP clock. Dual 32 bit timers can programmed to pace the acquisition process. The CPCI-AD16 can also accept external scan and trigger signals from a front panel connector.
-
Product
High-Voltage Differential Probe, 70 MHz
N2891A
High Current Probe
Use the N2891A 70-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2891A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to ±7000 V of differential and common mode voltage.
-
Product
Data Acquisition System - 3U 1-Slot
DAQ-31CP0G
Data Acquisition Module
The DAQ-31CP0G is a preconfigured rugged system with a high-performance, low power ARM® Cortex®-A9 processor. It is ideally suited to support a multitude of data acquisition applications that require high-density, multichannel, programmable communications consisting of: ARINC 429/575; Dual-Redundant, Quad Channel MIL-STD-1553B; CANBus (CAN 2.0 A&B or J1939) and Dual-Port Gig-E Ethernet.
-
Product
Brute Hight Current Probes
P4301
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45





























