Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Multiport Coaxial Switch, DC to 26.5 GHz, SP4T
87104C
The Keysight 87104C multiport switch improves insertion loss repeatability and isolation, which is necessary for higher performance test systems. The repeatability and reliability of this switch is vital to ATS measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. The Keysight 87104C terminated multiport switch provides the long life and reliability required for automated test and measurement, signal monitoring, and routing applications. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications. Low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy.
-
product
Portable Density/Specific Gravity Meter
DA-130N
Measuring method Natural Oscillation typeMeasurement object Liquid sample test materialsRange 0.0000 ~ 2.0000 g/cm3Precision 0.001 g/cm3Resolution 0.0001 g/cm3Temperature range 0 ~ 40.0CTemperature compensation Up to 10 entries for temperature compensation coefficient and converted temperatureAutomatic calibration All density values of pure water needed for auto calibration can be stored.Number of data 1,100 samplesExternal outputPC or Printer can be connected. (not both) IrDA interface is standard equipped. Connection via RS-232C requires optional infrared RS converter (98-029-0007).
-
product
Altitude Indicator and Pressure Transducer
AI100
Bemcos AI100 Altitude Indicator and Pressure Transducer provides a red, 5-digit scaled LED display of chamber or process Altitude, calibrated in feet or meters as well as a linear, scaled output of 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC for use with other instruments including process controllers, recorders, and programmable logic controls.
-
product
NIST Calibration for D400A-AT
D400A-AT-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Speed Switch
LRB1000/LRB2000
Features• Works with remote/external pulse frequency output sensor (NPN, PNP)• Over- or under-speed 1-1,000 rpm• 1 SPDT relay output (LRB1000) or 2 SPDT relay outputs (LRB2000)• Visual setpoint adjustment with digital accuracy• Dial-in calibration does not require power• Built-in start delay• DIN rail mounting simplifies installation• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options
-
product
Sphygmomanometer Calibrator
Huaxin Instrument (Beijing) Co., Ltd
Here at Huaxin, as an expert test equipment solution provider, we are proud to offer a selection of pressure calibrators for precise calibration of sphygmomanometer in laboratory and on site. Our sphygmomanometer calibrators find wide applications in metrology bodies, hospitals, university labs, etc.
-
product
Web Sensor
T7510
Web Sensor with built-in temperature, relative humidity and atmospheric pressure sensors. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Dial Torque Analyzer
MTS-Series
Dial Analyzer is designed for hand tools, like torque screwdrivers and torque wrenches. This tool is not suitable for power tools. Ideal for checking torque tools on production floor daily or weekly to ensure the tools aren't falling out of calibration, or can be used in cailbration lab. Using a quality torque tester makes a safer world through accuracy and precision. Measuring torque is essential for companies to ensure their product’s quality, safety and reliability isn’t compromised. The failure of a three-cent fastener that isn’t properly tightened can lead to catastrophic or latent failures.
-
product
Wide Dynamic Range Power Sensor, E-Series
E4412A
Fast measurement speed, up to 400 readings per second with the E4416AWide dynamic range (-70 dBm to +20 dBm)Calibration factors, linearity ana temperature compensations data stored in EEPROM Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to NIST Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
Insulation & Multifunction Tester (LCD Display)
4153 IN
Standard Electric Works Co., Ltd
Microprocessor-controlled. Measures Insulation Resistance, voltage (AC-DC) measurements with automatic hold facility, diode, ohm, and continuity with a short circuit current of minimum 220mA. Auto-off function. Energy conservation feature. Ener-Save™ limit the test duration to about 10 Seconds. Quick Test and EnerSave™ are unique features. Both saves energy. No moving parts. All calibration are saved internally in a non volatile memory. Easy calibration at any facility around the world. Operates with rechargeable batteries, alkaline or low cost general purpose batteries. Low cost maintenance, calibration, and ownership. Complies to all the latest regulations, including UK.
-
product
Accelerometers
An accelerometer is used in manufacturing machine maintenance to inspect equipment vibration. An accelerometer also is used in product testing to measure the vibration of various components.A triaxial accelerometer, also called a 3-axis accelerometer, provides measurements of the following parameters: vibration acceleration, vibration velocity and vibration displacement. In this way, vibration is measured and recorded with great precision.Most accelerometer products offered by PCE Instruments are portable devices. Many feature memory functionality so that readings can be stored and retrieved later for in-depth analysis. Some accelerometer models come with a manufacturer's calibration certificate. Some accelerometer models can be calibrated to ISO standards optionally for an additional fee.
-
product
Standard Resistors for Temperature Measurement
Measurements International Ltd.
High Stability, Split Guard Circuit, Internal Temperature Sensor, Custom Values Available, Includes Calibration Data.
-
product
Turns Counter for Bobbin Coils
TC-5 / TC-5A
International Electro-Magnetics, Inc.
The TC-5 is designed to verify the turns count of bobbin or free wound coils. When calibrated with a "Production Standard" coil, the TC-5 can measure to an accuracy of 99.9% or 1 turn in 1,000 for coils of less than 10,000 turns.
-
product
Pressure Control
Precise control of compressed gas is an intelligent approach to calibration. Ralston Instruments offers a number of pressure control devices for use in a wide range of applications and pressure levels.
-
product
Reference Temperature Sensors
AMETEK Sensors, Test & Calibration
Our reference sensors can be used as your daily working-reference sensors in laboratory or field calibration applications. A large selection of types are available, including; straight, 90 degree angle, 4 mm or 1/4”. The superior design and specifications combined with a long history of reliability and low drift have made the STS probes the working-standard in many EN/IEC 17025 accredited laboratories worldwide. The DLC sensors are a part of our patented Dynamic Load Compensation system.
-
product
Speed Sensor Intrinsically Safe
ST420
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected • Works with Electro-Sensors magnetic pulser discs / wraps Rugged stainless steel M18x1 housing; UL listed, Intrinsically Safe (IS); Class I, Div I (C, D) Class II, Div I (E, F, G)
-
product
Calibrators
TES Electrical Electronic Corp.
Unique mapping function let you calibrate temperature. iCal is a multifunction calibrator and an arbitrary function generator.
-
product
Probes, Sensors, Measurement Microphones, Calibrators, Accessories
Passive Probes, Active Probes, USB Isolators, Noise & Vibration Sensors & Accessories, Electro-Acoustic Test Accessories
-
product
Multilogger
M1322
Universal datalogger with 4 hardware inputs and internal CO2 sensor. Multilogger can be installed permanently to Ethernet network or work as portable device. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
-
product
Loop Calibrator
Model KM CAL-904-MK1
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
product
Network Simulator
SWAT WDS
Alethea Communications Technologies Pvt Ltd
Alethea’s SWAT WDS Network Simulator emulates the whole Customer Premises side with one box generating up to 32 CPEs with 4 ~ 8 ethernet clients behind each CPE. This setup which mirrors actual field deployment allows transmission points to be checked in detail as soon as the access point is setup. The solution gives a calibrated measure of the User Experience expected over the deployed system.
-
product
Handheld Water Quality Meters
LAQUA PC220
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
product
Crossover Calibrator
CC-1
The purpose of this tool is to enable the installer to set the crossover frequency of an electronic crossover to the desired frequency, accurately and quickly. It can also be useful for matching gains on multiple amplifier competition type systems.
-
product
Panel Meters & Avionics
Jewell Instruments offers the highest reliability combined with our proven, unique engineering and manufacturing capabilities. We are a leading provider of panel meters and traditional electro-mechanical avionic meter mechanisms and instruments. We perform all assembly, calibration, and testing in-house. Our solutions are ideal for a range of industrial, aerospace, and commercial applications.
-
product
Scalar Mixer / Converter Measurements
S96082B
The S96082B scalar mixer / converter measurements enables the highest accuracy for scalar conversion-loss / -gain measurements with a simple setup and calibration
-
product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm
CK519A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Water Treatment Plant Analyzer
Aqualog
Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.
-
product
Instrument Transformer Calibrators
CTPT 81
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).