Down Converters
Change a higher frequency signal to a lower frequency.
-
Product
Sources & Converters
-
High reliability, low-phase-noise, high-coherence, large operational temperature range, exceptionally low g-sensitivity for high vibration and shock performance.
-
Product
DC/DC Converter 3.5 W
REM3.5E-2409S/R6/A/SMD
-
DC/DC converter with 3.5 W from Recom | input ranges 18 - 36 VDC | output 9 V | operates in ambient temperature from -40 to +95 °C | SMT package
-
Product
DC/DC Converter 2 W
REM2-1509S
-
DC/DC converter 2 W from Recom | input ranges 13.5 - 16.5 VDC | output 9 V | operates in ambient temperature from -40 to +95 °C
-
Product
DC/DC Converter 50 W
CTS-60-6839
-
DC/DC converter with 50 W from Premium | input ranges 28.8 - 60 VDC | output 5 V | operates in temperatures from -25 - +85 °C | designed according to EN50155
-
Product
Modbus Register Converter - Serial To Modbus RTU Interface
-
Translates Modbus registers and variable types from an older Modbus devices to a new Modbus device. The Model 2390 allows upgrading Modbus RTU devices without changing the system software. The 2390 also provides serial control of Modbus RTU devices for new applications that want the ease of using simple ASCII commands strings when controlling Modbus RTU devices.
-
Product
DC/DC Converter 192 W
HP2540-9TB1G
-
DC/DC converter with 192 W from Bel Power Solutions | input ranges 16.8 - 137.5 VDC | two outputs at 15 V | operates in temperatures from -40 to +71 °C | provides 10 ms hold up time | 20 mm heatsink included
-
Product
Time to Amplitude Converters and Calibrator
-
A Time-to-Amplitude Converter (TAC) can achieve exceptional precision by using an analog technique to convert small time intervals to pulse amplitudes. When a timing application demands picosecond precision, a time-to-amplitude converter is a prime candidate. A time-to-amplitude converter is a productive solution for measurements less than 10 μs when time resolutions from 10 ps to 50 ns are required.
-
Product
Modbus Register Converter
Model 2390
-
* Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.